background image

 

5

 

IMPORTANT READ 

FIRST IMPORTANT

 

WARNING:

 

KEEP WATER AND SOLUTIONS OUT OF CONTROLS.  
NEVER SPRAY OR HOSE CONTROL CONSOLE, 
ELECTRICAL CONNECTIONS, ETC. 

CAUTION:

 

MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, 
MUCOUS MEMBRANES AND CLOTHING.  PRECAUTIONS 
SHOULD BE TAKEN TO WEAR RUBBER GLOVES, 
GOGGLES OR FACE SHIELD AND PROTECTIVE 
CLOTHING.  CAREFULLY READ THE WARNING AND 
FOLLOW THE DIRECTIONS ON THE LABEL OF THE 
CLEANER TO BE USED. 

NOTICE:

 

Service on this, or any other, STAR appliance must be 
performed by qualified personnel only.  Consult your 
authorized service agent directory or call the factory at  
1-800-807-9054 or visit our website 

WWW.STAR-MFG.COM

for the service agent nearest you. 

WARNING:

 

BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE 
THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED 
INTO A LIVE RECEPTACLE.  BEFORE REPLACING ANY 
PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC 
POWER SUPPLY. 

CAUTION:

 

USE OF ANY REPLACEMENT PARTS OTHER THAN 
THOSE SUPPLIED BY Star OR THEIR AUTHORIZED 
DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE 
OPERATOR AND DAMAGE TO THE EQUIPMENT AND 
WILL VOID ALL WARRANTIES.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DO54B

Страница 1: ...Sunnen Drive St Louis MO 63143 3800 Part Number 2M W476 Ph 314 781 2777 Fax 314 781 2714 Rev B WWW STAR MFG COM March 5 2008 Installation Operation and Maintenance Instructions Model DO54B Standard B...

Страница 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Страница 3: ...E 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 EQUIPMENT DESCRIPTION 6 4 UNPACKING 7 5 INSTALLATION 8 6 INITIAL START UP 10 7 OPERATION 11 8 CLEANING MAINTENANCE PROCEDURES 12 9 TROUBLESHOOTING 13 10 PARTS...

Страница 4: ...ONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind circuit breaker door on oven The oven voltage wattage serial num...

Страница 5: ...s or any other STAR appliance must be performed by qualified personnel only Consult your authorized service agent directory or call the factory at 1 800 807 9054 or visit our website WWW STAR MFG COM...

Страница 6: ...96 5 cm The interior is designed for baking on the rack or directly on the bottom surface of the oven Roast oven The interior dimensions are 12 30 5 cm High 30 76 2 cm Deep and 38 96 5 cm The interior...

Страница 7: ...LIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION CAUTION ANY STAND COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE LOCATED MUST BE DESIGNED TO SUPPORT...

Страница 8: ...nnections can be made through an 11 4 knockout in the bottom of the oven Remove the cover attached to the oven circuit breakers for access Power connections can be made at the bottom of the circuit br...

Страница 9: ...THE FRONT OF THE RANGE Three Phase Single Phase 208 Volt 240 Volt 480 Volt 208 V 240 V Number of Decks Total K W Conn L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 Single 6 0 28 8 28 8 0 25 0 25 0 0 12 5 12 5 0 2...

Страница 10: ...the low position and setting the thermostat to 350 degrees Allow the range ovens to saturate until all vapor and condensation has been eliminated For best operating results allow the ovens to thorough...

Страница 11: ...and bottom heat to suit the product to be baked or roasted The Roasting and Baking oven is equipped with a removable rack For baking pies bread or for roasting operations the rack may be placed direc...

Страница 12: ...of the clean sanitary features of electric equipment give it the regular attention that it deserves the same as any other highly perfected machinery to insure best results and continued high operatin...

Страница 13: ...ctory or call the factory at 1 800 807 9054 or visit our website WWW STAR MFG COM For the service agent nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT I...

Страница 14: ...el DO54R DO54B 54 Deck Oven 3827 54 Deck Oven SK2298 Rev A 2 05 2010 2 14 13 12 23 22 38 39 40 37 32 31 33 34 35 36 30 29 28 27 26 25 24 42 43 44 45 48 49 46 47 15 16 17 18 19 20 21 3 4 8 9 10 11 5 6...

Страница 15: ...RLNGSW DO54B 208V AND 240V DO54R 208V 240V AND 240VM 2E 31800 04 1 CB 480V 50A 3 POLE DO54B 2 3VM 440VM 480V AND 480VM DO54R 380V AND 480VM 15 N9 3827 240 1 CONTROL PANEL SPOT ALL MODELS 16 Q9 70701 0...

Страница 16: ...40V AND 240VM 2N 11070 19 2 ELMNT 3827OVEN 480V I S 1340W DO54B 480V 480VM DO54R 480V VM 2N 11070 21 2 ELE 3827OVN 380V IS 1340W DO54R 308V 45 2N 11070 10 2 ELMNT 3827OVEN 208V O S 1635W DO54B 208V DO...

Страница 17: ...OVEN AMPS PER LINE 240 VOLTS 43 3 25 0 43 3 43 3 43 3 25 0 25 0 L2 L1 25 0 0 0 L3 23827 33827 13827 LANG MODEL STAR MODEL DO542 DO543 DO541 AMPS 1 PHASE 75 0 50 0 86 5 57 7 18 0 12 0 25 0 240 V 208 V...

Страница 18: ......

Страница 19: ......

Страница 20: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...