INSTALLATION
DANGER
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL
PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD
RESULT IN ELECTROCUTION AND DEATH.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING.
IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL
AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE
The data plate is located behind the circuit breaker door on oven.
The oven voltage, wattage, serial number, wire size, and clearance
specifications are on the data plate. This information should be
carefully read and understood before proceeding with the
installation.
NOTICE
The installation of any components such as a vent hood, grease
extractors, fire extinguisher systems, must conform to their
applicable National, State and locally recognized installation
standards.
ELECTRICAL CONNECTION
Single Deck
Install the legs to the oven.
Electrical service connections can be made through an 11/4 knockout in the
bottom of the oven.
Remove the cover attached to the oven circuit breakers for access.
Power connections can be made at the bottom of the circuit breakers.
Multiple Decks
Perform installation of single deck.
Remove the plug button from the top panel of the lower deck, and install the
insulating bushing in the same hole.
Remove the vent cover stack from the lower deck by removing the screws that
secure the cover.
Place the upper deck on top of the lower deck. Screw heads and vent stack of the
lower deck will line up with the recesses in the bottom of the second deck.
Wire is supplied for making the electrical connections between the circuit breakers
of the upper deck and the incoming supply wires of the bottom deck. Connect 44-
inch wires to the bottom of the circuit breakers on the upper deck and identify
these as wires 3 and 4.
Route wires 3 and 4 to the bottom deck. Connect these wires to the supply side of
the bottom deck circuit breakers. Refer to PHASING for correct phasing.
To install additional deck repeat same steps above using appropriate wire lengths
and identifying them as wires 5 and 6.