background image

PARTS LIST

 

       

 

September 24, 2013, Rev. B

 

 

             

    

   

 IMPORTANT: WHEN ORDERING, INCLUDE MODEL AND SERIAL NUMBER 

Some items are included for illustrative purposes only and in certain instances may not be available.

   Number 

Per

Unit

Description and Model Designation

MODEL

Part

 Number

Key

  Number

     

     124CM 

Electric 

Cheesemelter

 

2C-20103-02 

SCRW SM PLT 10 X .5 PHLSL  124CM-208V & 240V, CMWOC-208

 

J9-MM-174 

BODY WRAP 2’ ALL

 

J9-MM-177 

REFLECTOR 2’ ALL

 

J9-MM-179 

REFLECTOR ANGLE 2’ & 4’ 

ALL

 

K9-11160-15 

QTZ HTR 208V/1200W 2FT 

124CM-208V, CMPT-208V, CMW-208V,  

 

 

 

 

 

   CMWOC-208

 

 

K9-11160-19 

QTZ HTR 104V/1200W 2FT 

124CM-208V, CMPT-208V, CMW-208V,  

 

 

 

 

 

   CMWOC-208

 

 

K9-11160-16 

QTZ HTR 240V/1200W 2FT 

124CM-240V, CMPT-240V, CMW-230/240V

 

 

K9-11160-20 

QTZ HTR 120V/1200W 2FT 

124CM-240V, CMPT-240V, CMW-230/240V

 

J9-MM-141 

LAMP SUPPORT BOTTOM L.H.  ALL

 

J9-MM-142 

LAMP SUPPORT BOTTOM R.H.  ALL

 

J9-MM-166 

SHELF PIVOT 2-3-4 FT   

ALL

 

2C-20101-24 

16 

SCRW MS PLT 10-32 X .375 

ALL

 

10 

2C-20202-07 

WSHR LOCK #10 STD SPLIT 

ALL

 

11 

2C-20301-15 

NUT HEX 10-32 PLTD   

ALL

 

12 

2B-50200-13 

RACK MELTER 24 

 

ALL

 

13 

J9-MM-167-1 

RACK SLIDE WELDMENT 5/16  ALL

 

14 

2C-20106-02 

SCRSHLDR HEXHD 

 

ALL

 

15 

2C-20202-08 

WSHR PLT 5/16 LOCK SPLIT 

ALL

 

16 

2C-20301-13 

NUT HEX 5/16-18 PLTD   

ALL

 

17 

J9-MM-143 

2’ BOTTOM SPOTWELD  

ALL

 

18 

2A-Z0314 

LEG 4 SS MM, GRID, FRYER 

124CM-208V & 240V, CMPT-208V & 240V

 

19 

J9-MM-153 

ACCESS PANEL 

 

ALL

 

20 

J9-MM-163 

BOTTOM INS. SUP. 2’   

ALL

 

21 

J9-MM-182 

BACK 2’ 

 

 

124CM-208V & 240V,

 

22 

J9-MM-185 

WALL BRACKET 2’ 

 

124CM-208V & 240V

 

23 

2J-31601-01 

PILOT LT 250V 6LEAD BLK 

ALL

 

24 

2M-60700-03 

CONTROL PANEL MM+2 36 

ALL

 

25 

2E-30303-06 

SWT TOG ON-ON DPDT BLK 

ALL

 

26 

2E-30701-03 

CONTC2POL35A208-240V50/60 ALL

 

27 

2C-20101-17 

SCRW RND MS 6-32X1 PLTD 

ALL

 

28 J9-GM-219 1 MICRO 

SWITCH 

ASSY 

 

ALL

 

29 

2C-20301-10 

NUT HEX 6-32 PLTD 

 

ALL

 

30 

2E-30500-08 

TERMINAL BLOCK 

 

ALL

 

31 

2E-31200-02 

GROUNDING LUG 

 

ALL

 

NI 

2H-60106-50 

INSULATION KIT 

 

ALL

 

NI 

2B-50201-04 

LAMP GUARD 24” 

 

ACCESSORY

 

NI 

2E-200376 

CORD SET, 14/3 208V   

124CMTC-208V, 240V

Содержание 124cm

Страница 1: ...ing 10 Sunnen Drive St Louis MO 63143 Rev B Phone 314 678 6315 Fax 314 781 2714 Part 2M 60803 01 www langworld com March 06 2013 Installation Operation Maintenance Electric Cheese Melter Model 124CM 1...

Страница 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Страница 3: ...IRST 4 EQUIPMENT DESCRIPTION 6 UNPACKING 7 INSTALLATION 8 OPERATION 11 MAINTENANCE CLEANING PROCEDURES 13 TROUBLE SHOOTING 14 124CM 136CM WIRING DIAGRAM 16 148CM WIRING DIAGRAM 17 EXPLODED VIEW 18 19...

Страница 4: ...CABLE CODES NOTICE The data plate is located on the left side of unit towards the front The melter voltage wattage serial number wire size and clearance specifications are on the data plate This infor...

Страница 5: ...longer than 10 minutes Longer contact can cause corrosion NOTICE Service on this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service agent directo...

Страница 6: ...and reduced heat loss Interior Construction The interior dimension are 9 5 24cm High 14 5 37cm Deep 21 25 32 45 25 54cm 81 25cm 115cm wide dependent on the actual model number The interior of the mel...

Страница 7: ...move the melter as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un cratin...

Страница 8: ...ent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards WALL MOUNT UNITS The unit back is not attached to the...

Страница 9: ...phase 148CM is shipped three phase and can be converted to single phase by moving wire 3 to L1 ELEMENT INSTALLATION Elements for all Lang electric Cheese melters are shipped packaged separately within...

Страница 10: ...LUE BLUE RED RED 104V OR 120V ELEMENT 104V OR 120V ELEMENT 208V OR 240V ELEMENT CONNECT BLUE BLUE RED CONNECT CONNECT CONNECT 208V OR 240V ELEMENT 104V OR 120V ELEMENT 104V OR 120V ELEMENT 208V OR 240...

Страница 11: ...ide the rack in and out of the slots provided Make sure that the end of the rack engages the sliding mechanism located on the right front corner CONTROLS Controls are located on the front panel and co...

Страница 12: ...rcuit the rear element appears dimly lighted and the front elements appear not energized In the AUTOMATIC mode the elements are activated to provide full heat only when product is placed on the rack P...

Страница 13: ...less steel surfaces longer than 10 minutes Longer contact can cause corrosion Cleaning Always start with a cold melter The stainless exterior can easily be cleaned using warm water and mild detergent...

Страница 14: ...type of failure then to the Possible Cause for the items to be checked To test for a possible causes refer to the TEST section and locate the Possible Cause then refer to test to identify test procedu...

Страница 15: ...Cause TEST Incorrect Voltage Confirm that is voltage is correct Confirm that melter is phased correctly Defective Power Switch Check switch for proper operation Failed Contactor Remove the wires from...

Страница 16: ...16 WIRING DIAGRAM 124CM 136CM...

Страница 17: ...17 WIRING DIAGRAM 148CM...

Страница 18: ...1 2 3 4 1 5 6 1 7 20 19 17 See Detail A 9 12 18 13 14 15 16 8 8 9 10 11 1 1 1 1 1 1 21 22 30 31 SK2246 Rev 5 2 07 Model 124CM Electric Cheesmelter...

Страница 19: ...23 25 24 26 11 9 27 28 29 SK2247 Rev 5 2 07 Model 124CM Electric Cheesmelter Control Panel Assembly 26 3 Pole 2 Pole Detail A...

Страница 20: ...C 20101 24 16 SCRW MS PLT 10 32 X 375 ALL 10 2C 20202 07 4 WSHR LOCK 10 STD SPLIT ALL 11 2C 20301 15 4 NUT HEX 10 32 PLTD ALL 12 2B 50200 13 1 RACK MELTER 24 ALL 13 J9 MM 167 1 1 RACK SLIDE WELDMENT 5...

Страница 21: ...LL 9 2C 20101 24 16 SCRW MS PLT 10 32 X 375 ALL 10 2C 20202 07 4 WSHR LOCK 10 STD SPLIT ALL 11 2C 20301 15 4 NUT HEX 10 32 PLTD ALL 12 2B 50200 14 1 RACK MELTER 36 ALL 13 J9 MM 167 1 1 RACK SLIDE WELD...

Страница 22: ...MS PLT 10 32 X 375 ALL 10 2C 20202 07 4 WSHR LOCK 10 STD SPLIT ALL 11 2C 20301 15 4 NUT HEX 10 32 PLTD ALL 12 2B 50200 15 1 RACK MELTER 48 ALL 13 J9 MM 167 1 1 RACK SLIDE WELDMENT 5 16 ALL 14 2C 2010...

Страница 23: ......

Страница 24: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Отзывы: