IOA170-1A January 2006
LANEX S.A.,8 Ceramiczna Street, 20-150 Lublin, Poland Service: Tel. 048 81 443 96 39
EtherCon
10/100Base-TX/E3 Converter TM-170.1
WITH
SNMP
AGENT
Operating Manual
Страница 1: ...IOA170 1A January 2006 LANEX S A 8 Ceramiczna Street 20 150 Lublin Poland Service Tel 048 81 443 96 39 EtherCon 10 100Base TX E3 Converter TM 170 1 WITH SNMP AGENT Operating Manual...
Страница 2: ...operties 13 5 2 MIB base description 14 5 3 Location of the TM 170 1 converter s MIB base in the registration tree 15 5 4 Traps 15 6 CONFIGURING THE CONVERTER USING LANWIN 16 6 1 Global configuration...
Страница 3: ...log 38 7 6 G 826 Statistics 39 8 TECHNICAL SPECIFICATIONS 42 8 1 Electrical parameters 42 8 1 1 E3 Line Interface 42 8 1 2 Ethernet Interface 42 8 2 Mechanical parameters 42 8 3 Environment requiremen...
Страница 4: ...NMP tab 18 Fig 6 6 Configuring the SNMP agent 18 Fig 6 7 Management system statistics window 19 Fig 6 8 E3 tab Monitoring 20 Fig 6 9 Interfaces Ethernet Configuration 21 Fig 6 10 Interfaces Ethernet M...
Страница 5: ...Data Link Control IEEE Institute of Electrical and Electronics Engineers ITU T International Telecommunication Union Telecommunication Standardization Sector LOS Loss Of Signal LOL Loss Of Lock loss...
Страница 6: ...Class 1 safety requirements Grounding terminal located on the rear panel of the device should be connected to grounding The device does not have a disconnecting system installed The said system should...
Страница 7: ...the converter The converter also transparently transmits longer than 1522 bite Ethernet frames which are a part of the virtual networks in compliance with the IEEE 802 1Q standard or with the setting...
Страница 8: ...er optic lines PDH and SDH telecom network E3 G 703 EtherCon EtherCon Ethernet Ethernet SDH PDH telecommunications network E3 G 703 Fig 1 1 Example of application I E3 G 703 FIBER OPTIC MODEM E3 G 703...
Страница 9: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 3 January 2006 1 3 Marking Device TM 170 1 Telecommunication device Type Version...
Страница 10: ...oss of the recovered clock s frequency ability ERR Error higher bit error rate than 10 6 and 10 3 TXD Transmission of Data to WAN RXD Receiving of Data from WAN 4 Group of panel light indicators signa...
Страница 11: ...nual IOA170 1A 5 January 2006 2 2 Rear panel 2 1 3 4 5 Fig 2 2 View and description of the rear panel 1 Ethernet port 1 interface receptacle 2 Ethernet port 2 interface receptacle 3 Interface E3 conne...
Страница 12: ...he converter is powered with a voltage range 24 60 VDC without the necessity of maintaining polarization on the power connector RJ 45 connector description 1 Ethernet signal input 2 Ethernet signal in...
Страница 13: ...ller enables configuration of the device and to monitor its operation status Servicing of the following protocols has been implemented SNMP version 1 as well as protocol group services of TCP IP TCP t...
Страница 14: ...sion 2 blinking indicator light 3 4 Quality management Quality management encompasses monitoring of E3 line transmission quality as well as packet transmission between LAN and WAN ports ensured by the...
Страница 15: ...isters Quality thresholds for the 15 minute period should be set in a range from 1 to 900 whilst the default values should be the following for ES 120 and for SES 15 There is not threshold value speci...
Страница 16: ...zed access to the device s configuration systems using the VT 100 terminal emulator in case of password security Viewing and deleting event log or defining the maximum and minimum threshold value for...
Страница 17: ...ave small impedance for very high frequencies Proper power supply is indicated by a green indicator light on the product s front panel The manufacturer does not recommend using impulse feeder due to t...
Страница 18: ...in8 1 Not connected 2 Not connected 3 Not connected 4 GND 5 RXD 6 TXD 7 Not connected 8 Not connected Fig 4 3 RS 232 cable with DB 9 RJ 45 pins 4 5 Ethernet interface configuration The converter has t...
Страница 19: ...ng points of the device are cumulated in the central management information base MIB Access to the base is possible through three methods as listed below through the SNMP agent servicing SNMP protocol...
Страница 20: ...ivate section groups main status ModuleConf ModuleMonit ModuleTestStat snmpmonit Table 5 shows data name variables types and their description Table 5 1 Variables in the system group Name Date type R...
Страница 21: ...e in the registration tree 5 4 Traps Information about alarm modes are forwarded to the administrator in a form of TRAP SNMP v1 frames with an error type description in the frame s data field They per...
Страница 22: ...p 4 4 3 6 1 Global configuration This tab allows to enter the name of the device date and time set up and to view additional information about the converter Fig 6 1 Global configuration 6 1 2 New devi...
Страница 23: ...set up and a window will open as shown below Fig 6 3 Date and time set up After entering changes click on OK and the changes will be updated in the device 6 1 4 Additional information After clicking...
Страница 24: ...m IP address of the device Subnet mask Community Name Management station IP address receiver of Trap SNMP type frames Gateway IP address Fig 6 6 Configuring the SNMP agent 6 3 Management system statis...
Страница 25: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 19 January 2006 Fig 6 7 Management system statistics window...
Страница 26: ...onitoring In this panel are shown parameters displaying the current E3 interface counter and indicators status described in p 3 4 Fig 6 8 E3 tab Monitoring Monitored parameters LOS Loss of Signal at i...
Страница 27: ...s half duplex forced operation in 100Mbit s half duplex 10Mbit s full duplex forced operation in 10Mbit s full duplex 10Mbit s half duplex forced operation in 10Mbit s half duplex AUTO automatic MDI o...
Страница 28: ...mber of packets received from Ethernet interface LANErrPacketRXCnt number of errored packets received from Ethernet interface LANFCtrlPacketRXCnt number of packets with flow control received from Ethe...
Страница 29: ...lock Source A clock for forwarded data to E3 G 703 interface may come from two sources From internal quartz 34 368 MHz 20 ppm frequency generator MASTER operation mode From clock recovery systems of t...
Страница 30: ...vent log In the Event Log tab shows registered events pertaining to the converter Types of registered events have been described in p 3 5 The user can delete the entire registered list of events in th...
Страница 31: ...teria tabs Events Allows to select the display of events of only one type of the shown above registered events list Data Enables the selection of events filtering time criteria This tab allows to sele...
Страница 32: ...clicking on the Hour of the counter start located on the right side of the ES SES window or after clicking on the window located below this button Configuration of switching ES15 SES15 ES24 SES24 erro...
Страница 33: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 27 January 2006 Fig 6 14 G 826 Statistics 15 minute counters Fig 6 15 G 826 Statistics 24 hour counters...
Страница 34: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 28 January 2006 Fig 6 16 G 826 Statistics time periods Fig 6 17 Hour of launching the counter Fig 6 18 Thresholds of setting the alarms on...
Страница 35: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 29 January 2006 Fig 6 19 Alarm hierarchy...
Страница 36: ...ems tests After passing the tests the device is ready to use Work with the terminal may begin with entering a start command after turning on the terminal and confirm by pressing ENTER The above comman...
Страница 37: ...case instead of the password enter kod01 The program will generate an eight digit sequence which is to be submitted to the LANEX service center Based on the sequence an emergency password will be gen...
Страница 38: ...System parameters The panel enables Modifying the name of the device Activating a password and entering a new one when entering a password during the launch of the terminal we will be asked to give th...
Страница 39: ...the direction of the E3 G 703 linear interface may come from two sources From internal quartz 34 368 MHz 20 ppm frequency generator MASTER operation mode From clock recovery systems of the opposite E3...
Страница 40: ...Fig 7 7 IP access configuration In order to prevent unwanted access to the management application access may be allowed by only selected users by entering appropriate IP addresses Lack of such entries...
Страница 41: ...Mbit s half duplex 10Mbit s full duplex forced operation in 10Mbit s full duplex 10Mbit s half duplex forced operation in 10Mbit s half duplex AUTO automatic MDI or MDI X configuration depending on co...
Страница 42: ...Monitoring 7 4 1 Monitoring E3 Fig 7 10 E3 monitoring Monitored parameters LOS Loss of Signal at input LOL Loss of Lock of recovered clock 10E 3 higher bit error rate than 10 3 10E 6 higher bit error...
Страница 43: ...cketRXCnt number of errored packets received from Ethernet interface LANFCtrlPacketRXCnt number of packets with flow control received from Ethernet interface LANFCtrlPacketTXCnt number of packets with...
Страница 44: ...uary 2006 7 5 Event log Fig 7 12 Event log In the EVENT LOG registered events of the converter are displayed Types of registered events have been described in p 3 5 In this panel it is possible to del...
Страница 45: ...of errored seconds ES Number of severe errored seconds SES Number of errored blocks EB Number of unavailable seconds UAS Additionally maximum and minimum threshold value for SES15 SES24 and ES15 ES24...
Страница 46: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 40 January 2006 Fig 7 15 Counting starting time Fig 7 16 15 minute registers...
Страница 47: ...E PERIODS panel Fig 7 18 the following are displayed Errored second ratio to all seconds when the device is available ESR Severe errored second ratio to all seconds when the device is available SESR T...
Страница 48: ...value 10Base T transmission speed 10 Mbit s full duplex and half duplex 100Base TX transmission speed 100 Mbit s full duplex and half duplex Input and output impedance 100 10Base T line code Mancheste...
Страница 49: ...Vibrations frequency 10 Hz do 55 Hz amplitude 0 15 mm duration time 10 cycles in three planes Degree of contamination Typical home or office environment 8 4 Electromagnetic compatibility The converter...
Страница 50: ...OA170 1A 44 January 2006 9 Product elements and accessories Full product set with accessories encompasses 1 TM 170 1 Converter 1 pcs 2 RS 232 DB 9 RJ 45 Cable 1 pcs 3 1 5 5 6 clamping connector male 2...
Страница 51: ...10Base T 100Base TX E3 Converter Operating Manual IOA170 1A 45 January 2006...
Страница 52: ...Operating Manual IOA170 1A 46 January 2006 Manufactured by Lanex S A 8 Ceramiczna Street 20 150 Lublin Poland Tel 48 81 444 10 11 Fax 48 81 740 35 70 e mail info lanex pl web www lanex pl Service Tel...