Page A - 74
A
LW 300 EC III / LW 450 EC III
Version: 24.04.18-001 E
S T O R A G E
Conservation / storage of the compressor
If the compressor is not to be used for an extended period of time, we recommend the follo-
wing conservation work to be carried out before the storage:
• Run the compressor at 200 bar for approx. ten minutes
• Drain warm oil and replace by new oil.
• Open filling valves and run the compressor for a few minutes.
• Stop the compressor and open the drain valves.
• Close filling valves.
• Open the final filter housing and lubricate the O-Ring with a food grade grease or silicone grease.
• Store the compressor in a cool dry place free from dust and contamination. A cover is recom-
mended as long as condensation can be avoided.
De-conservation, commissioning
After the compressor has been stored, the following steps are to be taken:
• Replace the final purification filter.
• Check oil level, replace oil if necessary. Fuel Driven Units only: Fill up fuel tank to top level to
avoid corrosion.
• Inspect the condition of the v-belts, replace if necessary
• Inspect the filling hoses visually for signs of deterioration, replace as necessary.
• Fix filling valves by e.g. cable strips to avoid whipping around wildly. Open filling valves.
• Open the filling valves and run the compressor for approx 10 minutes with the filling valves o-
pen.
• Close the filing valves and allow the compressor to build up to working pressure.
• Check the correct safety valve setting and/or pressure switch setting (option).
• Check all connections and pipe work for leaks, retighten if necessary.
Once the above steps are completed to satisfaction, the unit is ready to use.
Содержание LW 300 EC III
Страница 3: ...A Operating Instructions Breathing Air Compressor LW 300 EC III LW 450 EC III Version 04 18 E ...
Страница 12: ...A S A F E T Y P R E C A U T I O N S ...
Страница 19: ...A I N S TA L L AT I O N ...
Страница 26: ...A O P E R AT I O N ...
Страница 34: ...A R E M E D Y I N G FA U LT S ...
Страница 39: ...A M A I N T E N A N C E A N D S E R V I C E ...
Страница 70: ...A M A I N T E N A N C E R E C O R D S ...
Страница 78: ...B Operating Instructions ECC Electronic compressor control www uebler net Version 11 12 E ...
Страница 98: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Страница 101: ...C Version 25 08 2017 D E T A I L A N S I C H T D E T A I L E D V I E W Gehäuse Housing C 2 LW 300 450 E Compact III ...
Страница 139: ...C Version 26 10 2017 D E T A I L A N S I C H T D E T A I L E D V I E W Motor Motor C 40 LW 300 450 E Compact III ...
Страница 143: ...C Version 27 02 2017 D E T A I L A N S I C H T D E T A I L E D V I E W Ölpumpe Oil Pump C 44 LW 300 450 E Compact III ...
Страница 146: ...D O P T I O N S ...
Страница 148: ...D A U T O S H U T D O W N D 1 LW 300 450 E Compact III ...
Страница 152: ...D Version 24 04 2018 A U T O S H U T D O W N Druckschalter Pressure Switch D 5 LW 300 450 E Compact III ...
Страница 153: ...D A U T O M A T I C C O N D E N S AT I O N D R A I N D 6 LW 300 450 E Compact III ...
Страница 186: ...D A U T O S T A R T F U N C T I O N D 39 LW 300 450 E Compact III ...
Страница 192: ...D O I L P R E S S U R E G A U G E D 45 LW 300 450 E Compact III ...
Страница 195: ...D O I L P R E S S U R E M O N I T O R I N G D 48 LW 300 450 E Compact III ...
Страница 201: ...D O I L T E M P E R A T U R E M O N I T O R I N G D 54 LW 300 450 E Compact III ...
Страница 204: ...D C Y L I N D E R H E A D T E M P E R AT U R E M O N I T O R I N G D 57 LW 300 450 E Compact III ...
Страница 207: ...D I N T E R S TA G E P R E S S U R E G A U G E S D 60 LW 300 450 E Compact III ...
Страница 210: ...D 2 0 0 3 0 0 B A R PA R A L L E L F I L L I N G P R E S S U R E O P E R AT I O N D 63 LW 300 450 E Compact III ...
Страница 217: ...D A I R C O O L E R C O N N E C T I O N K I T D 70 LW 300 450 E Compact III ...
Страница 220: ...D C O N D E N S A T E TA N K 6 0 LT R D 73 LW 300 450 E Compact III ...
Страница 225: ...E A T T A C H M E N T Version 11 12 E ...