background image

L&L VENT-SURE DOWNDRAFT KILN VENT INSTRUCTIONS

ventsure-instruct.pdf 

REV: 8/1/2017 

Page 7

©

 

2017  

 

L&L Kiln Mfg, Inc.  505 Sharptown Rd, Swedesboro NJ 08085  856.294.0077   F:856.294.0070   [email protected]   hotkilns.com   

OPTIONAL VENT CONTROL

For more information see:  

hotkilns.com/vent-control
The Vent Control allows you to automatically control the 

operation of the Vent-Sure kiln vent with one of the outputs 

from the DynaTrol (or Genesis).

Construction

The Vent Control consists of a relay that is controlled from 

output #4 on the DynaTrol (or Genesis).
There is a female 120 volt receptacle to plug the vent into 

and a cord to plug into a 120 volt wall outlet.
There is a 6 foot wire that connects the control box to the 

kiln control panel. A grommet is included for non-factory 

installation.

Where It Can Be Used

It is only available for kilns with DynaTrols and Genesis 

controls.
It may not be used with kilns with powered bottoms 

(because the same output on the control is used)

Operation

NOTE: These options are set in the “Hidden Menu” of the 

DynaTrol.

OPTION A (OP A)

Used to control a vent. Output 4 can be programmed to 

be on or off during each segment of a Vary-Fire program. 

During an Easy-Fire program, output 4 comes on at the 

beginning of the firing and turns off after the kiln has cooled 

to 150F.

OPTION B (OP B)

Used to control a vent. Output 4 can be programmed to 

be on or off during each segment of a Vary-Fire program. 

Output 4 comes on at the beginning of an Easy-Fire 

program, off at 1450°F, back on after the firing is complete 

and the kiln has cooled to 1000°F and finally off again when 

the temperature is below 150°F.

OPTION C (OP C)

Used to control a vent, an alarm, or other atmospheric 

control. Output 4 can be programmed to be on or off during 

each segment of a Vary-Fire program. Output 4 is off during 

Easy-Fire programs.

FREQUENTLY ASKED QUESTIONS

How do I know if the system is working?

See our comments under “Adjusting the Bypass Valve” 

How hot does the duct get during the firing?

Not very, for two reasons. One is that the Vent-Sure does not 

draw out much heat from the kiln. The hotter the kiln gets, the 

less hot air that is extracted by the vent motor. The other is that 

the bypass box combines fresh cool air with the hot air from the 

kiln before passing through the ductwork. 

How long can the duct be and how many 

bends can it have?

Up to 60 feet of ducting containing four 90 degree bends 

may be safely used with no drop in static air flow at the duct 

exhaust point or a reduction in draw at the kiln. The ducting 

can be run either horizontally or vertically. (The Vent-Sure 

should handle more static pressure than the Orton vent 

because of the stronger motor. This translates into longer 

lengths of pipe and more 90 degree bends. If you have a 

choice run two 45 deg bends rather than one 90 degree 

bend or use flexible duct which has a gentler bend).

Can I vent through a ceiling and/or roof?

Yes. You will need the multi-mounting bracket (M-V-

MULT/00), so that you can position the motor output 

vertically. Additionally, you need to make sure that you install 

a water trap. At the bottom of the longest vertical run, install a 

u-shaped bend to catch any condensation that forms before 

it enters the motor. Of course if you are going through a roof, 

you will also need a rain cap and screen.
You do not normally need double wall ducting when going 

through the roof since the pipe or duct does not reach high 

temperature. It is always advisable to check your local 

building codes for their requirements.

Содержание M-V-VENT/00

Страница 1: ...to understand in order to operate your L L kiln ventilation system safely and effectively USEFUL WEB LINKS See this video on how to install a vent hotkilns com install vent sure See this video on how to drill holes for a vent hotkilns com drilling holes vent sure vent system TABLE OF CONTENTS 1 READ THE INSTRUCTIONS 1 USEFUL WEB LINKS 1 CHECKING SHIPMENT 2 WHAT IS INCLUDED WITH VENT 2 IMPORTANT CA...

Страница 2: ...h built into the motor DO NOT place anything in the blower motor while powered Serious injury and or damage to the motor could result INSTALLATION TIP BEFORE STARTING NOTE Attach the Bypass Box to the stand and the aluminum duct to the Bypass Box before installing the kiln on the stand because it can be hard to do this when the kiln is on top of the stand CHECKING SHIPMENT Your ventilation system ...

Страница 3: ...KE CERTAIN KILN POWER IS OFF BEFORE PROCEEDING WITH INSTALLATION Step 1 Turn Off Kiln Power This is critical for safety reasons Step 2 Drill Holes if needed Before mounting the Bypass Box you should drill the vent holes Note if you bought the vent system with a new kiln it should be pre drilled The easiest way to drill the vent holes is to place the stand upside down on the kiln bottom center it a...

Страница 4: ... or wall with the outlet of the vent pointing up This is useful when you want to use an existing penetration in a wall that won t support the vent like a window or when you want to have the vent go out of a roof or into a central vent system Step 6 Connect Flexible Duct Attach blower system to bypass collection box by stretching the flexible aluminum duct carefully it can extend up to 15 feet and ...

Страница 5: ...ow of exhaust a larger flow control opening reduces the flow of exhaust fumes from the kiln and a smaller flow control opening increases the exhaust ADJUSTING THE BYPASS SYSTEM The sliding adjuster allows you to fine adjust the amount of venting that is done to your kiln It is easy to adjust but hard to know just how to adjust it The problem is that there are many factors that contribute to the am...

Страница 6: ...duct Replace if necessary Check for corrosion especially if you are using clay with a high content of sulfur phosphorus or fluorine Check for wax or carbon build up if you are using a wax resist process or a high carbon content clay We recommend unmounting the fan and blowing out the squirrel cage with compressed air every two years or so especially if you are in a very dusty or if you have it mou...

Страница 7: ...ol a vent an alarm or other atmospheric control Output 4 can be programmed to be on or off during each segment of a Vary Fire program Output 4 is off during Easy Fire programs FREQUENTLY ASKED QUESTIONS How do I know if the system is working See our comments under Adjusting the Bypass Valve How hot does the duct get during the firing Not very for two reasons One is that the Vent Sure does not draw...

Страница 8: ...cubic foot kiln firing an 85 pound load on Fast Glaze program to cone 8 took 70 KW hours with a vent on and 62 KW hours without a vent At 8 cents per KW hour that would be a cost of 0 64 more for the firing The vent was on the whole time Will the cold air entering the kiln damage the product No The amount of air coming in is too small unless you drill holes in the lid which is not normally recomme...

Страница 9: ...d to vent don t waste heat and energy by venting more than you need EXTERNAL VENTING External venting is safer and surer than venting to the inside of your kiln room with a filter REMOTE MOUNTING OF MOTOR The vent blower motor is mounted to a wall plate with a 12 length of exhaust pipe that mounts on the wall see photo This keeps the heat of the kiln away from the motor for longer motor life and k...

Страница 10: ... All Position Housing Finish Gray Enamel Housing Material Rolled Steel The Vent Sure vent is c MET us listed in both the US and Canada for use with L L listed kilns UL 499 CSA C22 2 No 122 CSA C22 Listing No E112742 PARTS Prices of all parts are listed at hotkilns com parts Complete Vent Sure Kiln Vent System M V VENT 00 see web VENT SURE Vent 120 Volt Complete System as described above and on our...

Страница 11: ...ration to be mounted to any L L kiln stand It can also be mounted to the side of other kilns typically on the bottom section Bypass Collection Box M V MULT 00 see web Mult Mounting Bracket Comes with six 6 sets of 1 4 20 bolts nuts and lock washers for mounting this to the Wall mount bracket M V VENT BK This special Multi Mounting Bracket will allow you to mount the vent on the floor or wall with ...

Отзывы: