Operator Manual S755 (G2) / S755 XL (G2)
October 2017
Landis International - 26
LOST OF SUCTION IN DUST COLLECTION
1.
Dust drawer may be full. Empty it.
2.
Blower fan may be clogged. Remove the dust container.
Remove the trap and clean the blower fan. Replaced the
trap and the dust container.
3.
Finisher too close to the back wall.
Your Finisher should be 6”
distance from the wall.
BELT CREEPS
Belt worn out or frayed one side. Install new belt.
MOTOR STOPS WITH SWITCH ON
CAUTION!
Turn switch off immediately
1.
Too much equipment operated on same circuit on which Landis S755
(G2)
/
S755 XL
(G2)
Finisher is connected. Check circuit breaker or fuse box.
2.
An overload may have caused the thermal overload protector in motor to shut
off current. Be sure sander is off, then find and eliminate cause for overload.
Some motors are equipped with manual Re-Set thermal overload protector wait
at least 30 minutes, then firmly press Re-Set button on motor with eraser end of
pencil or a small blunt dowel. After approximately 30 minutes you should be able
to hear or feel overload protector click in when pushed to reset. After Re-Set
clicks in, turn switch on and motor should run normally. If the motor has no Re-
Set button, wait 30 minutes that the engine would shrink. After this time, the
engine should reset itself.