Warning

The meter contains lithium batteries. Do not dispose of the

meter and batteries as household waste. Observe local

regulations and laws regarding disposal.

Warning

After lithium batteries have been used, you can return

them to the manufacturer for proper disposal. When

shipping batteries please observe legal regulations which

among other things govern the labelling and packaging of

hazardous goods.

Warning

Do not open the batteries. Do not bring batteries into

contact with water or expose to temperatures exceeding

80°C.

Warning

The meter has no lightning protection. Ensure lightning

protection via the house installation.

3 Operating elements

Figure 1: Meter, closed

Figure 2: Meter, open

Number

Description

1

Button 1

2

Button 2

3

Security stamp

4

Screw

5

Optical interface

6

LCD

7

Service button

4 Installation

Note

For a heat meter 

 or combined heat/cooling meter, the

cold side installation location corresponds to the return

 and the warm side installation location to the supply
.

Note

In the case of a cooling meter 

, the warm side

installation location corresponds to the return 

 and the

cold side installation location to the supply 

.

Proceed as follows to install the meter:

1.

Compare the installation location with the symbol on the
LCD (

 or 

) to determine the installation location. If

necessary, adjust the installation location of the meter to

match the conditions (see chapter "Changing the installation

location").

2.

Note the dimensions of the meter and check whether there

is sufficient free space.

3.

Flush the system thoroughly before installing the meter.

4.

Install the meter vertically or horizontally between two gate

valves so that the arrow on the body matches the flow

direction. Please note the following installation examples.

5.

Install the temperature sensors in the same circuit as the

meter.

6.

Seal temperature sensors and screw connections to prevent

manipulation.

7.

Remove the rubber band from the volume measuring part.

During operation, the temperature sensor cable and control

line should not be in direct contact with the volume

measuring part.

8.

If you install the meter as a cooling meter, follow the

corresponding instructions.
Recommendation: If you install several meters, the same

installation conditions should apply to all meters.

© Gyr

Subject to change without prior notice

07.02.2020

2

Содержание T450

Страница 1: ...arantees Caution Comply with the requirements for circulation water CEN TR 16911 2016 Caution The meter is only suitable for circulation water in heating systems Caution The meter is not suitable for...

Страница 2: ...ion corresponds to the return and the cold side installation location to the supply Proceed as follows to install the meter 1 Compare the installation location with the symbol on the LCD or to determi...

Страница 3: ...Press button 2 briefly to complete the change The change can be checked using the symbols or on the LCD If necessary adjust the temperature sensors according to the installation requirements 4 2 Inst...

Страница 4: ...e temperature sensors are horizontal or vertical Figure 7 Recommended installation position of cooling meters and combined heat cooling meters 5 Calculator The ambient temperature of the calculator mu...

Страница 5: ...follows to change the battery If necessary open the battery compartment cover by loosening the screw Remove the old batteries from the battery compartment Insert the battery into the battery compartm...

Страница 6: ...on Note No later than 60 seconds after installation the meter automatically detects the inserted modules and is ready for communication or pulse output 7 2 Terminal blocks 2 pin or 4 pin terminals are...

Страница 7: ...be displayed without incorrect installation Error Incorrect flow direction negative Check whether the flow direction arrows on the volume meter correspond to the flow direction of the system If the di...

Страница 8: ...necessary or Error in internal memory Change the device The measurements of the meter may no longer be used for legally calibrated billing Error code Error Information for Service F2 F3 F5 or F6 pers...