![LandCell CDM819s Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/landcell/cdm819s/cdm819s_user-manual_3486673025.webp)
The <parity> argument is only valid when <format> is set to 2. The default
settings for the modem are
AT+ICF=3,1
.
8.8 Cellular CDMA Commands
The cellular CDMA commands use the same syntax as the other extended commands.
Numeric values are decimal. The following table describes the cellular CDMA
commands.
Table 6: CDMA AT Parameter Commands Table
Command
Description
+CAD?
Query Analog Or Digital Service.
Returns:
0: If no service is available.
1: If CDMA digital service is available.
2: If TDMA digital service is available.
3: If analog service is available.
Values 4-255 are reserved.
+CSS?
Serving System
Read Only. Returns <AB>, <SID>
AB:
A: The mobile station is registered with an A-band system.
B: The mobile station is registered with a B-band system.
Z: The mobile station is not registered.
SID:
0-16383: The mobile station is registered with the system indicated.
99999: The mobile station is not registered.
+CSQ?
Query Received Signal Quality.
Returns the Signal Quality and Frame Error Rate as follows:
Signal Quality Measure <SQM>:
0-31: Signal Quality Measurement (See note 1 below)
99: SQM is not known or is not detectable.
All other values are reserved.
Frame Error Rate <FER>:
0: <0.01%
1: > 0.01% and < 0.1%
2: > 0.1% and < 0.5%
3: > 0.5% and < 1.0%
4: > 1.0% and < 2.0%
5: > 2.0% and < 4.0%
6: > 4.0% and < 8.0%
7: >= 8.0%
99: FER is not known or is not detectable.
All other values are reserved.
Note 1: The exact meaning of the Signal Quality Measure <SQM> shall be
manufacturer defined. The lowest quality reported by SQM shall be defined as
value: 00. The highest quality reported by SQM shall be defined as value: 31.
+CDR
Um Interface Data Compression Reporting
This extended-format numeric parameter controls whether the extended-format
+CDR intermediate result code is transmitted by the MT2.
+CDS
Um Interface Data Compression