manualshive.com logo in svg
background image

ZF SERIES PRESSURE WASHER  

OPERATOR’S MANUAL

3

LANDA ZF   

•  

REV. 9/02

INTRODUCTION

Thank you for purchasing a Landa Pressure Washer.

This manual covers the operation and maintenance of
the ZF2-10021D  washer. All information in this manual
is based on the latest product information available at
the time of printing.

Landa, Inc. reserves the right to make changes at any
time without incurring any obligation.

The ZF Series was designed for maximum

use of 1 hour per day, 5 days per week.

Owner/User Responsibility:

The owner and/or user must have an understanding of
the manufacturer’s operating instructions and warnings
before using this Landa pressure washer. Warning infor-
mation should be emphasized and understood. If the op-
erator is not fluent in English, the manufacturer’s instruc-
tions and warnings shall be read to and discussed with
the operator in the operator’s native language by the pur-
chaser/owner, making sure that the operator compre-
hends its contents.

Owner and/or user must study and maintain for future
reference the manufacturers’ instructions.

This manual should be considered a permanent
part of the machine and should remain with it if
machine is resold.

When ordering parts, please specify model and
serial number.

IMPORTANT SAFETY
INFORMATION

CAUTION: To reduce the risk of
injury, read operating instruc-
tions carefully before using.

1. Read the owner's manual thor-

oughly. Failure to follow instruc-
tions could cause malfunction
of the pressure washer and re-
sult in death, serious bodily in-
jury and/or property damage.

2. Know how to stop the machine and bleed pressures

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.

4. All installations must comply with local codes. Con-

tact your electrician, plumber, utility  company or the
selling distributor for specific details.

To comply with the National Electrical code (NFPA
70) and provide additional protection from risk of elec-
tric shock, this pressure washer is equipped with a
UL-approved ground fault circuit interrupter (GFCI)
power cord.

WARNING: Flammable liquids
can create fumes which can ignite
causing property damage or se-
vere injury.

  5. Risk of explosion — do not

spray flammable liquids or op-
erate in an explosive location.

WARNING: Keep water spray
away from electric wiring or fatal
electric shock may result. Read
warning tag on electrical cord.

  6. To protect the operator from

electrical shock, the machine
must be electrically grounded.
It is the responsibility of the
owner to connect this machine

to a UL grounded receptacle of proper voltage and
amperage ratings. Do not spray water on or near
electrical components. Do not touch machine with
wet hands or while standing in water. Always dis-
connect power before servicing.

  7. Grip cleaning wand securely with both hands before

star ting the cleaner. Failure to do this could result in
injury from a whipping wand.

WARNING: Equipment can produce
a high pressure stream of fluid that
can pierce skin and its underlying
tissue, leading to serious injury and
possible amputation.

  8. High  pressure  developed  by

these machines can cause
bodily injury or damage. Use
caution when operating. Do not
point the spray  gun at anyone
or at any part of the body.

9. Never make adjustments on machine while in op-

eration.

WARNING: High pressure spray
can cause paint chips or other
particles to become airborne and
fly at high speeds.

  10. Eye safety devices must be worn

when using this equipment.

WARNING

KEEP WATER SPRAY

AWAY FROM

ELECTRICAL

WIRING.

WARNING

RISK OF EXPLOSION:

DO NOT USE WITH

FLAMMABLE

LIQUIDS.

WARNING

HIGH PRESSURE

STREAM CAN

PIERCE SKIN AND

TISSUES.

WARNING

USE PROTECTIVE

CLOTHING WHEN

OPERATING.

WARNING

READ OPERATOR’S

MANUAL THOROUGHLY

PRIOR TO USE.

C AUTION

Содержание ZF2-10021D

Страница 1: ...ERATOR S MANUAL LANDA INC 4275 N W Pacific Rim Blvd Camas WA 98607 USA For technical assistance or the Landa Dealer nearest you call 800 LANDA 4 U 800 526 3248 or 360 833 9100 or consult our web page...

Страница 2: ...ety Information 3 5 Component Identification 4 Pre Operation Check 5 Set Up Procedures 5 Operating Instructions 5 How to Use the Multireg Nozzle 6 Nozzle Installation 6 Cleaning and Changing Nozzle 6...

Страница 3: ...umber utility company or the selling distributor for specific details To comply with the National Electrical code NFPA 70 and provide additional protection from risk of elec tric shock this pressure w...

Страница 4: ...re Indicator Gauge 1 94871800 Pressure Indicator Gauge Clip 1 36257751 Pressure Indicator Gauge Cover 1 36257851 Pressure Indicator Gauge Needle 9 ITEM PART NO DESCRIPTION 5 1 93502700 ON OFF Switch 6...

Страница 5: ...e the wand by pushing the two halves to gether and then fix by turning the connector to tighten 4 Connect wand to trigger gun by turning the connec tor Attach high pressure hose to trigger gun and tig...

Страница 6: ...ow pressure is by push pull action The selection of the pressure must be carried out with the spray gun in closed position trigger released High pressure nozzle pushed forward Low pressure nozzle pull...

Страница 7: ...t economy After wash ing rinse from the top down 3 Cleaning heavy dirt or material away with a hard stream of clear water is recommended before using a cleaning agent SHUT DOWN PROCEDURES 1 Rinse all...

Страница 8: ...ozzle in to select low pressure C 4 At this point the suction and mixing of the detergent will start automatically 5 The quantity of detergents can be regulated by ad justing the detergent control kno...

Страница 9: ...the machine is frozen or blocked due to lime deposits By taking these precautions before starting the machine you will avoid damaging it Remove the key before switching on the motor CHECKING AND CHAN...

Страница 10: ...31 Fix Up 1 12 4 0111429 Quick Lance 5 Extension 20 1 13 4 012191 Gun Shut Off 1 14 4 02011225 Hose Cpl 25 x 1 4 1 15 4 2010 Nozzle Multireg 1 QUICK LANCE MULTIREG NOZZLE 4 2010 ITEM PART NO DESCRIPTI...

Страница 11: ...0 Guide Spring 1 7 1 90356800 O Ring 1 0105 2 8 1 90500700 Anti Ext Ring 1 0105 1 9 1 18205370 Shaft 1 10 1 94730500 Spring 1 ITEM PART NO DESCRIPTION Kit No QTY 11 1 18205051 Latch 1 12 1 94730300 Sp...

Страница 12: ...12 ZF SERIES PRESSUREWASHER OPERATOR S MANUAL LANDA ZF REV 9 02 WIRING DIAGRAM ZF2 10021D START WINDING POWER CORD SWITCH RED PINK BLACK CAPACITOR RED PINK BROWN RUN WINDING GREEN GROUND BLACK WHITE...

Страница 13: ...r tight Valves dirty or worn Check clean or replace Worn bearings Check and replace if necessary Water too hot Reduce temperature below 140 PRESENCE OF WATER IN OIL High humidity in air Check and chan...

Страница 14: ...AST OIL CHANGE BRAND NAME AND TYPE OF OIL See above PUMP OIL CHANGE RECORD The level of oil must be checked periodically The first important oil change must be carried out after the first 20 hours of...

Страница 15: ...rvice including adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While...

Страница 16: ...operador de un choque el ctrico la m quina deber de estar conectada a tierra Es la responsa bilidad del due o de conectar esta m quina a un recept culo a tierra aprobado por UL con el amper age y vol...

Страница 17: ...ada 2 Connecci n de manguera de alta presi n salida 3 Bot n de regulaci n de presi n 4 Indicador de presi n 5 Prendido Apagado 6 Regulador de detergentes ARTICULO DESCRIPCION 7 Fix Up 8 Medidor de niv...

Страница 18: ...hasta la mitad de la mira de vidrio no detergente 30 wt Si el nivel de aceite no est visible como se ha descrito agregar aceite seg n sea necesario INSTRUCCIONES DE OPERACION 1 Con el interruptor de c...

Страница 19: ...tirar la boquilla desentorn illando con un llave hex agonal Limpiar la boquilla soplandoaire Si est degastada cambiarla TECNICAS GENERALES DE LAVADO 1 Mantener la boquilla de rociado aproximadamente a...

Страница 20: ...lizar la boquilla multireg hacia adentro para seleccionar baja presi n C En este punto la succi n y la mezcla de los productos detergentes empezar autom ticamente Usted puede regular la cantidad de pr...

Страница 21: ...a o bloqueada debido a sedimentos calcificados Al tomarse estas precauciones antes de arrancar se evitar n da os en la unidad Retirar la llave antes de arrancar el motor REVISANDO Y CAMBIANDO EL ACEIT...

Страница 22: ...t rmica 4 Da o a los componentes debido a fluctuaciones en el suministro el ctrico o al abastecimiento de agua 5 Servicio de mantenimiento normal incluso los ajustes limpieza del sistema de combustib...

Страница 23: ......

Страница 24: ...4275 NW Pacific Rim Blvd Camas WA 98607 USA Form 96 6072 Revised 9 02 Printed in U S A by Landa Inc Camas WA 98607 WATER CLEANING SYSTEMS...

Отзывы: