96-610 • LANDA VNG/VLP • REV. 9/05
13
PRESSURE
W
ASHER
OPERA
T
OR’S MANU
AL
OPERATION INSTRUCTIONS
1.STOP! Read operator’s manual
before operating this machine.
Failure to read operation and
warning instructions may re-
sult in personal injury or prop-
erty damage.
2. Turn all switches off.
3. Review installation instruc-
tions.
4. Connect water supply hose to
the inlet connector and turn water on. Check for
water leaks and tighten as needed.
5. Turn on the main gas supply and turn the gas valve
control knob into the “ON” position (see page 14).
6. Close the steam knob and detergent valve by turn-
ing clockwise and setting the temperature control
knob between 200°- 225°F.
7. Attach the desired high pressure nozzle into the
wand quick coupler by pulling the coupler collar
back and inserting the nozzle. Secure nozzle by
pushing the coupler collar forward.
8. Turn the pump switch on to start the machine. When
spray gun is closed a time delay feature will turn
the machine off.
9. For hot water, push the burner switch to the ON
position and pull the trigger on the spray gun. Spark-
ing begins, the pilot gas ignites and then the igni-
tor/sensor will turn the main burner on. Optional
remote control requires the pump switch to be
turned ON before the burner and detergent
switches will turn on.
10. To apply detergent, open the detergent valve coun-
terclockwise making sure that the detergent pick
up tube is in the detergent solution and not suck-
ing air. With optional remotes, the detergent switch
needs to be turned to the OFF position before turn-
ing to the ON position to activate the detergent so-
lenoid.
11. To Stop: Turn the burner switch off and place the
detergent pick-up tube into fresh water. Open the
detergent valve and trigger spray gun allowing de-
tergent lines to be flushed and the burner to cool.
Otherwise, coil damage will result.
12. When steam is needed, remove the side panel and
turn the steam knob counterclockwise. Then turn
the temperature adjustment knob to 275°F.
13. After water has cooled, turn pump switch to OFF
position. If the machine is going to be off for an
extended period of time, put the manual valve on
the gas valve into the OFF position.
14. Turn the water off. Protect from freezing.
WARNING
READ OPERATOR’S
MANUAL THOROUGHLY
PRIOR TO USE.
Selection of high or low pressure is accompanied by
turning the handle. Note: High pressure nozzle must
be inserted at end of wand to obtain high pressure. To
apply soap read operator's manual.
Variable Pressure
Control Handle
Trigger
Variable Pressure
Wand (VP)
High
Pressure
Nozzle
Brass Soap
Nozzle