Maintenance

Fuel

Use clean fuel oil that is not contaminated with water 
and debris. Replace fuel filter and drain tank every 100 
hours of operation. 

Use No. 1 or No. 2 heating oil (ASTM D306) only. 

NEVER 

use gasoline in your burner fuel tank. Gasoline 

is more combustible than fuel oil and could result in a 
serious explosion. 

NEVER

 use crankcase or waste oil 

in your burner. Fuel unit malfunction could result from 
contamination.

Fuel Control System

This machine utilizes a fuel solenoid valve located on 
the fuel pump to control the flow of fuel to the combus-
tion chamber. The solenoid, which is normally closed, is 
activated by a flow switch when water flows through it. 
When the operator releases the trigger on the spray 
gun, the flow of water through the flow switch stops, 
turning off the electrical current to the fuel solenoid.

The solenoid then closes, shutting off the supply of fuel 
to the combustion chamber. Controlling the flow of fuel 
in this way gives an instantaneous burn-or-no-burn situ-
ation, thereby eliminating high and low water tempera-
tures, and combustion smoke normally associated with 
machines incorporating a spray gun. 

CAUTION: Periodic inspection, to insure that the 
fuel solenoid valve functions properly, is recom-
mended. This can be done by operating the 
machine and checking to see that the burner is not 
firing when the spray gun is in the off position.

ATTENTION: Une inspection périodique est 
recommandée pour assurer que l'électrovalve 
d'alimentation en carburant fonctionne 
correctement. Cela peut être effectué en utilisant la 
machine et en s'assurant que le brûleur n'est pas 
allumé lorsque le pistolet pulvérisateur se trouve 
en position d'arrêt.

Fuel Pressure Adjustment

To adjust fuel pressure, First install a pressure gage 
into the port just after the pump fuel exit. Turn the 
adjusting screw (located at the regulator port) 
clockwise to increase, and counterclockwise to 
decrease. Do not exceed 200 psi or lower the pressure 
below 130 PSI, when checked at the post-pump 
pressure port. 

The fuel pressure may need to be adjusted due to 
altitude. For every 500 ft altitude above sea level, the 
boiling point of water goes down 1 °F. At high altitude 

environments, this boiling point change may require the 
heat input to be lowered so the water input does not 
turn to steam earlier than at the factory settings and 
activate the pressure sensors and pressure relief 
equipment when the unit is operated and much higher 
altitudes from factory settings or local dealer site 
settings. Check with your dealer before making local 
site fuel pressure adjustments.

Also, as ambient temperature changes seasonally, the 
fuel temperature in the feed tank and air temperature 
inlet can impact fuel flow. In more extreme tempera-
tures, this local-site adjustment may also require 
different fuel nozzles for fuel inlet temperatures that are 
at seasonal extremes (higher or lower) in locations 
where the temperature changes are beyond moderate 
temperatures of between 40°F and 90°F. Colder 
temperatures will make for a thicker flow and less fine a 
fuel spray while hotter temperatures will make for a 
thinner flow a more fine spray with the same nozzle. 
Consider alternate nozzle configurations from the 
baseline factory-supplied nozzle for operating in such 
temperature extremes if performance is not meeting 
needs with air band and fuel pressure settings alone.

NOTE:

 When changing fuel pump, a bypass plug must 

be installed in return port or fuel pump will not prime.

Burner Nozzle

Keep the tip free of surface deposits by wiping it with a 
clean, solvent-saturated cloth, being careful not to plug 
or enlarge the nozzle. For maximum efficiency, replace 
the nozzle each season.

Electrode Setting

Landa SLT/SLX Gas Operator’s Manual  8.914-002.0 - AR

5/32" Gap

1/16"

Nozzle

Electrode

7/16"

 SLX-

10

  (

ONLY)

Содержание SLT6-32324E 1.110-520.0

Страница 1: ...ts i e pain t thin ner gas olin e oil Tri s odiu m pho sph ate prod ucts Amm onia prod ucts Acid bas ed prod ucts The se che mic als will harm the unit and will dam age the surf ace bein g clea ned Us...

Страница 2: ...2 Landa SLT SLX Gas Operator s Manual 8 914 002 0 AR Machine Data Label...

Страница 3: ...nloader Valves 15 Winterizing Procedure 15 High Limit Hot Water Thermostat 15 Pumps 15 Cleaning of Coils 15 Removal of Soot and Heating Coil 15 Pressure Relief Valve 15 Rupture Disk 15 Fuel 16 Burner...

Страница 4: ...good working condition They are listed in this general order Storage Engine Maintenance Unloader Valves Winterizing Procedure High Limit Hot Water Thermostat Pump Cleaning of Coils De liming Coils Rem...

Страница 5: ...e used only by trained opera tors Important Safety Information WARNING To reduce the risk of injury read operating instructions carefully before using AVERTISSEMENT Pour r duire le risque de blessures...

Страница 6: ...ray flammable liquids AVERTISSEMENT Risque d incendie Ne pas pulv riser de liquides inflammables 7 Allow engine to cool for 1 2 minutes before refueling If any fuel is spilled make sure the area is dr...

Страница 7: ...mage Keep clear of nozzle Use caution when oper ating Do not direct discharge stream at people or animals or severe injury or death will result AVERTISSEMENT La haute pression g n r e par ces machines...

Страница 8: ...eam explosion 26 Do not overreach or stand on unstable support Keep good footing and balance at all times 27 Do not operate this machine when fatigued or under the influence of alcohol prescription me...

Страница 9: ...ump damage Landa SLT SLX Gas Operator s Manual 8 914 002 0 AR Nev er Use Ble ach chlo rine pro duc ts and oth er cor ros i v e che mic als Liqu ids con tain ing solv ent s i e pain t thin ner gas olin...

Страница 10: ...ty latch on the spray gun trigger STEP 8 Fill gasoline tank and check engine oil level Fill fuel oil tank Do not confuse gasoline and fuel oil tanks Keep proper fuel in proper tank Read engine manual...

Страница 11: ...1 pour pr venir les dommages la surface et l injection et les blessures STEP 2 Read engine manual provided and pull choke Pull spray gun trigger to relieve pressure Then turn the engine switch to the...

Страница 12: ...pray at a slight angle Recommendations Before cleaning any surface an inconspicuous area should be cleaned to test spray pattern and distance for maximum cleaning results If painted surfaces are peeli...

Страница 13: ...f and continue spraying allowing the water to cool to below 100 STEP 4 Squeeze trigger on spray gun to relieve remaining pressure STEP 2 Turn engine key switch off STEP 3 Turn off water supply Landa S...

Страница 14: ...TE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during storage Such additives may be added to the gasoline in the fuel tank of the engine...

Страница 15: ...omatically reset itself The thermostat sensor is located on the discharge side of the heating coil The thermostat control dial is located on the control panel Pumps Use only SAE 10W 40 weight non foam...

Страница 16: ...t Turn the adjusting screw located at the regulator port clockwise to increase and counterclockwise to decrease Do not exceed 200 psi or lower the pressure below 130 PSI when checked at the post pump...

Страница 17: ...ditional burner component information see Burner Assembly page It is recommended that the oil burner be serviced yearly or as needed Contact your local service center Burner Air Adjustment To adjust s...

Страница 18: ...high altitude main jet in the carburetor Contact your local authorized engine sales and service center for details Valves sticking Check and clean or replace if necessary Unloader valve seat faulty Ch...

Страница 19: ...COLD START ONLY WHEN BURNER IS OFF Fuel is improper or water is in fuel Drain tank and replace contaminated fuel Air adjustment is improper Readjust air bands on burner assembly Fuel pressure is low...

Страница 20: ...ecessary EXCESSIVE VIBRATION IN DELIVERY LINE Irregular functioning of the valves Check and replace if necessary DETERGENT NOT DRAWING Air leak Tighten all clamps Check detergent lines for holes Restr...

Страница 21: ...e of your pressure washer Perform maintenance more often under severe conditions Landa SLT SLX Gas Operator s Manual 8 914 002 0 AG Maintenance Schedule Pump Oil Non foaming SAE 10W 40 Inspect Oil lev...

Страница 22: ...8 914 002 0 Printed in U S A...