Safety

WARNING: Protect machine 
from freezing.

AVERTISSEMENT: Protéger la 
machine contre le gel.

16.To keep machine in best 
operating conditions, it is 
important you protect machine 
from freezing. Failure to protect 
machine from freezing could 
cause malfunction of the machine 

and result in death, serious bodily injury, and/or 
property damage. Follow storage instructions 
specified in this manual.

17.  Inlet water must be clean fresh water and no hotter 

then 90°F.

DANGER: Risk of asphyxiation. 
Do not inhale fumes. Use this 
product only in a well ventilated 
area. Running this product 
indoors can result in death due 
to carbon monoxide, a 
poisonous gas you cannot see 
or smell. Never operate indoors 
even if windows and doors are 
open. Only use outdoor and far 
away from windows, doors, and 

openings or vents.

DANGER: Risque d'asphyxie. Ne pas inhaler les 
vapeurs. Utiliser ce produit uniquement dans un 
endroit bien ventilé. L'utilisation de ce produit à 
l'intérieur peut causer la mort par monoxyde de 
carbone, un gaz toxique incolore etinodore. Ne 
jamais utiliser à l'intérieur, même si les fenêtres et 
les portes sont ouvertes.

18. Manufacturer will not be liable for any changes 

made to our standard machines or any compo-
nents not purchased from us.

19. The best insurance against an accident is precau-

tion and knowledge of the machine.

WARNING: Be extremely careful 
when using a ladder, scaf-
folding or any other relatively 
unstable location. The cleaning 
area should have adequate 
slopes and drainage to reduce 
the possibility of a fall due to 
slippery surfaces.

AVERTISSEMENT: Faire preuve 
d'une extrême prudence au 

moment d'utiliser une échelle, des échafaudages 
ou toute autre surface relativement instable. La 
zone de nettoyage doit avoir une pente et un 
drainage adéquats pour réduire la possibilité d'une 
chute due à une surface glissante.

20. Do not allow acids, caustic or abrasive fluids to 

pass through the pump.

21. Never run pump dry or leave spray gun closed 

longer than 1-2 minutes.

22. Machines with shut-off spray gun should not be 

operated with the spray gun in the off position for 
extensive periods of time as this may cause 
damage to the pump.

23. Protect discharge hose from vehicle traffic and 

sharp objects. Inspect condition of high pressure 
hose before using or bodily injury may result.

24. Before disconnecting discharge hose from water 

outlet, turn burner off and open spray gun to allow 
water to cool below 100° before stopping the 
machine. Then open the spray gun to relieve 
pressure. Failure to properly cool down or maintain 
the heating coil may result in a steam explosion.

25. Do not overreach or stand on unstable support. 

Keep good footing and balance at all times.

26. Do not operate this machine when fatigued or 

under the influence of alcohol, prescription medica-
tions, or drugs.

WARNING: Do not spray 
machine or any people, animals 
or electrical parts.

AVERTISSEMENT: Ne pas 
vaporiser sur la machine ou les 
gens, les animaux ou les pièces 
électriques.

Follow the maintenance instruc-
tions specified in the manual. 

Suivre les instructions d'entretien 
spécifiées dans le manuel.

WARNING

PROCTECT FROM

FREEZING

DANGER

RISK OF 

ASPHYXIATION. 

USE THIS PRODUCT 

ONLY IN A WELL 

VENTILATED AREA.

WARNING

RISK OF INJURY

FROM FALLS WHEN

USING LADDER.

WARNING

DO NOT SPRAY 

MACHINE OR ANY 

PEOPLE, ANIMALS OR 

ELECTRICAL PARTS.

Landa SLT/SLX Kubota Diesel Operator’s Manual  9.807-540.0 - E

Содержание SLT Series

Страница 1: ...E INDO ORS Asse mble d in USA Use Appro ved Deter gent Only Conta ins comp onent s from one or more of the follow ing count ries Unite d States China Italy Japan and Thaila nd 8 93 2 96 8 0 MODELS SL...

Страница 2: ...tenance Glow Plug When the light is on the engine is being pre heated When the light turns off the engine can be started Low Oil When the light is on it means check the oil level Add oil if needed Bat...

Страница 3: ...t Down And Clean Up 13 Maintenance Storage 14 Engine Maintenance 14 Maintenance And Service 14 Unloader Valves 15 Winterizing Procedure 15 High Limit Hot Water Thermostat 15 Pumps 15 Cleaning of Coils...

Страница 4: ...e Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize the operator with the operation and...

Страница 5: ...guage by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufacturers instructions The operator must know...

Страница 6: ...le spraying Safety glasses do not provide full protection 6 Keep operating area clear of all persons WARNING Flammable liquids can create fumes which can ignite causing property damage or severe injur...

Страница 7: ...l shut off valve OFF CAUTION Hot discharge fluid Do not touch or direct discharge stream at persons or animals WARNING This machine produces hot water and must have insulated components attached to pr...

Страница 8: ...tr me prudence au moment d utiliser une chelle des chafaudages ou toute autre surface relativement instable La zone de nettoyage doit avoir une pente et un drainage ad quats pour r duire la possibilit...

Страница 9: ...ump damage 9 80 1 42 7 0 OF F GLST DO NOT OVE RLO AD GEN ERA TOR Units equip ped with optio nal gene rator shou ld not excee d 1000 watts resis tive load See Serv ice Manu al for detai ls CA UT IO N O...

Страница 10: ...o insert your choice of pressure nozzle CAUTION Never replace nozzles without engaging the safety latch on the spray gun trigger ATTENTION Ne jamais remplacer les buses sans d abord mettre le disposit...

Страница 11: ...807 540 0 E 9 8 01 427 0 OFF GL ST DO NO T OV ER LO AD GE NE RA TO R Unit s equ ippe d with opti ona l gen erat or sho uld not exce ed 100 0 wat ts resi stiv e load See Serv ice Man ual for deta ils...

Страница 12: ...op Allow detergent to remain on surface 1 3 minutes Do not allow detergent to dry on surface If surface appears to be drying simply wet down surface with fresh water If needed use brush to remove stub...

Страница 13: ...3 Turn engine key switch off Burner Switch 9 80 1 4 27 0 OF F GL ST DO NOT OVE RLO AD GEN ERA TOR Units equi pped with optio nal gene rator shou ld not exce ed 1000 watt s resis tive load See Serv ic...

Страница 14: ...r 4 Cover the pressure washer and store in a clean dry place that is well ventilated away from open flame or sparks After Extended Storage CAUTION Prior to restarting thaw out any possible ice from pr...

Страница 15: ...erating temperature the high limit control will turn the burner off until the water cools then automatically reset itself The thermostat sensor is located on the discharge side of the heating coil The...

Страница 16: ...e located on the fuel pump to control the flow of fuel to the combus tion chamber The solenoid which is normally closed is activated by a flow switch when water flows through it When the operator rele...

Страница 17: ...not to plug or enlarge the nozzle For maximum efficiency replace the nozzle each season Electrodes Setting SLT 6 8 only Burner Air Adjustment The oil burner on this machine is preset for operation at...

Страница 18: ...om each side of coil and tank assembly these bolts are used to fasten tank to chassis 5 Remove fittings connected to the 1 2 pipe nipples from inlet and discharge sides of coil 6 Remove top tank wrap...

Страница 19: ...ually Replace High Pressure Nozzle Every 6 months Replace Quick Connects Annually Clean Water Screen Filter Weekly Replace HP Hose Annually Kubota Engine Maintenance Schedule Engine Oil SAE 10W 30 API...

Страница 20: ...foaming oil Engine Oil Check daily before first use of your new Power Washer Change pump oil after first 50 hours and every 200 hours thereafter Use SAE 10W 30 API CF rating Cj 4 DateOilChanged Month...

Страница 21: ...n X X X Engine overload X X X X X X X Excessive parasitic load X X X Valve lash insufficient excessive X X X X Injection timing out of spec advanced X X X X X Injection timing out of spec retarded X X...

Страница 22: ...pressure control valve Rebuild or replace as needed Slow engine RPM Set engine speed at proper specifications Pump sucking air Check water supply and possibility of air seepage Valves sticking Check...

Страница 23: ...y Engine altitude The engine is preset for operation at altitudes below 1000 feet above sea level If operated at higher altitudes it may be necessary to contact your local authorized engine sales and...

Страница 24: ...place Incorrect fuel nozzle size Contact your local Landa Dealer Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOISY Air...

Страница 25: ...s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves sticking Chec...

Страница 26: ...9 807 540 0 Printed in U S A...