Assembly Instructions
STEP 1:
Read safety, installation
and preventative maintenance
instructions before connecting the
water supply hose to the float tank
inlet swivel connector and turning
on water supply.
STEP 4:
Adding exhaust vent pipe
to your oil fired burner is not recom-
mended because it restricts air
flow. This causes carbon build-up,
which affects the operation and
increases maintenance on the coil.
If a stack must be used, refrain
from using 90° bends. If the pipe
can not go straight up then use only
45° bends and go to the next larger
size pipe. The overall pipe length
must not exceed 6 feet in length.
Air adjustments will be required
after installation.
STEP 2:
Water source for
machines should be supplied by a
3/4" I.D. garden hose with a city
water pressure of not less than 30
PSI. If the water supply is inade-
quate, or if the garden hose is
kinked, the machine will run very
rough and the burner will not fire.
STEP 3:
Fill fuel tank with proper
fuel: kerosene, No. 1 home heating
fuel or diesel.
Landa PHW Operator’s Manual 8.917-417.0 - D
Fuel
Cap