background image

19

Maintenance

PROBLEM

POSSIBLE CAUSE

SOLUTION

BURNER WILL 

NOT LIGHT

(continued from 

previous page)

Flex coupling slipping on fuel pump 

shaft or burner motor shaft

Replace if needed.

On-Off switch defective

Check for electrical current reaching 

burner assembly with burner switch on.

Heavy sooting on coil and burner can 

cause interruption of air flow 

and shorting of electrodes

Clean as required.

Improper electrode setting

Check and reset according to diagram in Operator’s 

Manual.

Fuel not reaching combustion 

chamber

Check fuel pump for proper flow. Check solenoid flow 

switch on machines with spray gun control, for 

proper on-off fuel flow control.

Clogged burner nozzle

Clean as required.

Thermostat faulty or slow engine 

speed

Increase engine RPM to increase voltage.

Flow switch malfunction

Remove, test for continuity and replace as needed.

Flow solenoid malfunction

Replace if needed.

FLUCTUATING

PRESSURE

Valves worn

Check and replace if necessary.

Blockage in valve

Check and replace if necessary.

Pump sucking air

Check water supply and air seepage at joints in 

suction line.

Worn piston packing

Check and replace if necessary.

Gasoline engine altitude

The gasoline engine is preset for operation at 

altitudes below 1000 feet above sea level. If 

operated at higher altitudes, it may be necessary to 

install a high altitude main jet in the carburetor. 

Contact your local authorized engine sales and 

service center for details.

MACHINE 

SMOKES

WHILE 

BURNER UNIT 

IS RUNNING 

OR

UNIT SMOKES 

AT COLD-START 

ONLY WHEN 

BURNER 

IS OFF 

Improper fuel or water in fuel

Drain tank and replace contaminated fuel.

Improper air adjustment

Readjust air bands on burner assembly.

Fuel pressure is low <140 psi for 

burner

Adjust fuel pump pressure to specifications.

Plugged or dirty burner nozzle

Replace nozzle. Check parts breakdown 

for nozzle size

Faulty burner nozzle spray pattern

Replace nozzle. Check parts breakdown 

for nozzle size.

Heavy accumulation of soot on coils 

and burner assembly

Remove coils and burner assembly, 

clean thoroughly. Call local dealer.

Misaligned electrode setting

Realign electrodes to specifications.

Obstruction in smoke stack

Check for insulation blockage or other foreign 

objects.

Low engine RPM

Increase RPM to correct specs. See serial plate.

Fuel Pressure is too high for clean 

burn (fuel PSI above 140 and below 

200) and smokes when burner is off

Reduce fuel pressure PSI/Increase air band set for 

cleaner without max water heat loss

Landa PGHW Operator’s Manual   8.916-485.0 - BW

Содержание PGHW4-3000

Страница 1: ...ty XXXX XXX XXXX XX X XXXX XXX XXXX XX XXXX XXX XXXX GAS 8 916 274 0 DIE SEL 8 932 960 0 MODELS PGHW4 3000 1 110 048 0 PGHW4 4000 1 110 047 0 PGHW5 3000 1 110 046 0 PGHW5 3500 1 110 045 0 PGHW8 3000 1...

Страница 2: ...2 Landa PGHW Operator s Manual 8 916 485 0 BW Machine Data Label...

Страница 3: ...ions 10 Battery Installation 10 Operation Instructions 11 Detergents General Cleaning Techniques 12 Thermal Pump Protection 12 Cleaning Tips 12 Shutting Down And Clean Up 13 Maintenance Storage 14 Aft...

Страница 4: ...ion and function of the machine The MAINTENANCE section contains preventive main tenance to keep the machine and its components in good working condition They are listed in this general order Storage...

Страница 5: ...by trained opera tors Important Safety Information WARNING To reduce the risk of injury read operating instructions carefully before using AVERTISSEMENT Pour r duire le risque de blessures lire attent...

Страница 6: ...fueling If any fuel is spilled make sure the area is dry before testing the spark plug or starting the engine Fire and or explosion may occur if this is not done Gasoline engines on mobile or portable...

Страница 7: ...des dommages l quipement Se tenir l cart de la buse Faire preuve de prudence lors de l utilisation Ne pas d charger directement le jet vers des personnes ou des animaux car cela risquerait de causer...

Страница 8: ...100 before stopping the machine Then open the spray gun to relieve pressure Failure to properly cool down or maintain the heating coil may result in a steam explosion 26 Do not overreach or stand on u...

Страница 9: ...tergent Valve Engine Switch Fuel Cap Hose Reel Garden Hose Not Included High Pressure Nozzle Spray Wand Pillow Tank Spray Gun Water Connection Hose Valve Assembly High Pressure Hose Float Tank Burner...

Страница 10: ...Install proper battery making sure that the red cable is attached to the positive terminal Use a 12V Group 24 battery on all models except 4 40321 and 5 35321E These models use a U1 30 amp garden tra...

Страница 11: ...t water turn the burner switch to ON when a steady stream of water flows out of the spray gun Burner will now light automatically NOTE Do not start machine with burner switch on STEP 3 Pull wand coupl...

Страница 12: ...pump protector engages and cools the pump by discharging the warm water onto the ground This thermal device prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh wa...

Страница 13: ...10 Burner Switch Se nD EC TAC H H OU R 1 10 Engine Key Switch Liquides contenant des solvants c d diluant peinture essence huiles etc Produits base de tripolyphosphate de sodium Ammoniac ou produits b...

Страница 14: ...flame or sparks NOTE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during storage Such additives may be added to gasoline in fuel tank of t...

Страница 15: ...hermostat For safety each machine is equipped with a tempera ture sensitive high limit control switch In the event that the water should exceed its operating temperature the high limit control will tu...

Страница 16: ...low 130 PSI when checked at the post pump pressure port The fuel pressure may need to be adjusted due to altitude For every 500 ft altitude above sea level the boiling point of water goes down 1 F At...

Страница 17: ...ocal state and federal regulations CAUTION If white smoke appears from burner exhaust vent during start up or operation discon tinue use and readjust air bands ATTENTION Si de la fum e blanche s chapp...

Страница 18: ...n Leaking pressure control valve Rebuild or replace as needed Slow engine RPM Set engine speed at proper specifications Pump sucking air Check water supply and possibility of air seepage Valves sticki...

Страница 19: ...ne altitude The gasoline engine is preset for operation at altitudes below 1000 feet above sea level If operated at higher altitudes it may be necessary to install a high altitude main jet in the carb...

Страница 20: ...ce Incorrect fuel nozzle size See specifications for proper fuel nozzle Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOI...

Страница 21: ...nt line s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves stick...

Страница 22: ...ent Contact your Landa dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe conditions Maintenanc...

Страница 23: ...e pump oil after first 50 hours and every year or 500 hours thereafter Use SAE 10W 40 non foaming oil DateOilChanged Month Day Year Estimated Operating Hours Since Last Oil Change DateOilChanged Month...

Страница 24: ...8 916 485 0 Printed in U S A...

Отзывы: