Maintenance

Oil Burner

Burner Air Adjustment

: The oil burner on this 

machine is preset for operation at altitudes below 500 

feet. If operated at higher altitudes, it may be necessary 

to adjust the air band for a #1 or #2 smoke spot on the 

Bacharach scale.
To adjust, start machine and turn burner ON. Loosen 

two locking screws found on the air band and close air 

band until black smoke appears from burner exhaust 

vent. Note air band position. Next, slowly open the air 

band until white smoke just starts to appear. Turn air 

band halfway back to the previously noted position. 

Tighten locking screws.
For higher altitudes, the air band opening may need to 

be increased; for lower altitude, the .air band may need 

to be decreased.
For higher humidity, the air band opening may need to 

be increased; for lower relative humidity, the .air band 

may need to be decreased.
For higher ambient temperatures the air band opening 

may need to be increased; for lower ambient tempera

-

tures, the air band opening may need to be decreased.
Adjust to your operating location's environment as-

needed for best smoke spot and performance 

compliant with local, state, and federal regulations.

CAUTION: If white smoke appears from burner 

exhaust vent during start-up or operation, discon

-

tinue use and readjust air bands.
ATTENTION: Si de la fumée blanche s'échappe de 

l'évacuation du brûleur pendant le démarrage ou le 

fonctionnement, cesser d'utiliser et réajuster les 

bandes d'air.

NOTE: If a flue is installed, have a professional 

serviceman adjust your burner for a #1 or #2 smoke 

spot on the Bacharach scale.

Coil Removal

Removal of coil because of freeze breakage, or to 

clean soot from it can be done quickly and easily.
1.  Disconnect hose from pump to inlet side of the 

coil.

2. Carefully disconnect the thermostat sensor making 

sure you do not crimp the capillary tube.

3. Remove burner assembly from combustion 

chamber.

4. Remove the 3-3/8” bolts from each side of coil and 

tank assembly (these bolts are used to fasten tank 

to chassis).

5. Remove fittings connected to the 1/2” pipe nipples 

from inlet and discharge sides of coil.

6. Remove top tank wrap, bend back insulation tabs 

and fold back blanket.

7. Remove bolts that hold down coil to bottom wrap.
8. Remove coil.
9. Replace or repair any insulation found to be torn or 

broken.

10. Remove insulation retainer plates.

Coil Reinstallation

To reinstall new or cleaned coil, reverse steps 9 through 

1.

Landa PGHW Operator’s Manual   8.916-485.0 - BW

Содержание PGHW4-3000

Страница 1: ...ty XXXX XXX XXXX XX X XXXX XXX XXXX XX XXXX XXX XXXX GAS 8 916 274 0 DIE SEL 8 932 960 0 MODELS PGHW4 3000 1 110 048 0 PGHW4 4000 1 110 047 0 PGHW5 3000 1 110 046 0 PGHW5 3500 1 110 045 0 PGHW8 3000 1...

Страница 2: ...2 Landa PGHW Operator s Manual 8 916 485 0 BW Machine Data Label...

Страница 3: ...ions 10 Battery Installation 10 Operation Instructions 11 Detergents General Cleaning Techniques 12 Thermal Pump Protection 12 Cleaning Tips 12 Shutting Down And Clean Up 13 Maintenance Storage 14 Aft...

Страница 4: ...ion and function of the machine The MAINTENANCE section contains preventive main tenance to keep the machine and its components in good working condition They are listed in this general order Storage...

Страница 5: ...by trained opera tors Important Safety Information WARNING To reduce the risk of injury read operating instructions carefully before using AVERTISSEMENT Pour r duire le risque de blessures lire attent...

Страница 6: ...fueling If any fuel is spilled make sure the area is dry before testing the spark plug or starting the engine Fire and or explosion may occur if this is not done Gasoline engines on mobile or portable...

Страница 7: ...des dommages l quipement Se tenir l cart de la buse Faire preuve de prudence lors de l utilisation Ne pas d charger directement le jet vers des personnes ou des animaux car cela risquerait de causer...

Страница 8: ...100 before stopping the machine Then open the spray gun to relieve pressure Failure to properly cool down or maintain the heating coil may result in a steam explosion 26 Do not overreach or stand on u...

Страница 9: ...tergent Valve Engine Switch Fuel Cap Hose Reel Garden Hose Not Included High Pressure Nozzle Spray Wand Pillow Tank Spray Gun Water Connection Hose Valve Assembly High Pressure Hose Float Tank Burner...

Страница 10: ...Install proper battery making sure that the red cable is attached to the positive terminal Use a 12V Group 24 battery on all models except 4 40321 and 5 35321E These models use a U1 30 amp garden tra...

Страница 11: ...t water turn the burner switch to ON when a steady stream of water flows out of the spray gun Burner will now light automatically NOTE Do not start machine with burner switch on STEP 3 Pull wand coupl...

Страница 12: ...pump protector engages and cools the pump by discharging the warm water onto the ground This thermal device prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh wa...

Страница 13: ...10 Burner Switch Se nD EC TAC H H OU R 1 10 Engine Key Switch Liquides contenant des solvants c d diluant peinture essence huiles etc Produits base de tripolyphosphate de sodium Ammoniac ou produits b...

Страница 14: ...flame or sparks NOTE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during storage Such additives may be added to gasoline in fuel tank of t...

Страница 15: ...hermostat For safety each machine is equipped with a tempera ture sensitive high limit control switch In the event that the water should exceed its operating temperature the high limit control will tu...

Страница 16: ...low 130 PSI when checked at the post pump pressure port The fuel pressure may need to be adjusted due to altitude For every 500 ft altitude above sea level the boiling point of water goes down 1 F At...

Страница 17: ...ocal state and federal regulations CAUTION If white smoke appears from burner exhaust vent during start up or operation discon tinue use and readjust air bands ATTENTION Si de la fum e blanche s chapp...

Страница 18: ...n Leaking pressure control valve Rebuild or replace as needed Slow engine RPM Set engine speed at proper specifications Pump sucking air Check water supply and possibility of air seepage Valves sticki...

Страница 19: ...ne altitude The gasoline engine is preset for operation at altitudes below 1000 feet above sea level If operated at higher altitudes it may be necessary to install a high altitude main jet in the carb...

Страница 20: ...ce Incorrect fuel nozzle size See specifications for proper fuel nozzle Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOI...

Страница 21: ...nt line s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves stick...

Страница 22: ...ent Contact your Landa dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe conditions Maintenanc...

Страница 23: ...e pump oil after first 50 hours and every year or 500 hours thereafter Use SAE 10W 40 non foaming oil DateOilChanged Month Day Year Estimated Operating Hours Since Last Oil Change DateOilChanged Month...

Страница 24: ...8 916 485 0 Printed in U S A...

Отзывы: