INTRODUCTION

Thank you for purchasing a Landa Pressure Washer.

This manual covers the operation and maintenance of the
MPE5-50021B and MPE5-50021C  washers. All informa-
tion in this manual is based on the latest product informa-
tion available at the time of printing.

Landa, Inc. reserves the right to make changes at any
time without incurring any obligation.

The MPE Series was designed for maximum

use of 8 hours per day, 5 days per week.

Owner/User Responsibility:

The owner and/or user must have an understanding of
the manufacturer’s operating instructions and warnings
before using this Landa pressure washer. Warning infor-
mation should be emphasized and understood. If the op-
erator is not fluent in English, the manufacturer’s instruc-
tions and warnings shall be read to and discussed with
the operator in the operator’s native language by the pur-
chaser/owner, making sure that the operator compre-
hends its contents.

Owner and/or user must study and maintain for future
reference the manufacturers’ instructions.

This manual should be considered a permanent
part of the machine and should remain with it if
machine is resold.

When ordering parts, please specify model and
serial number.

IMPORTANT SAFETY
INFORMATION

CAUTION: To reduce the risk of
injury, read operating instruc-
tions carefully before using

 1. Read the owner's manual thor-

oughly. Failure to follow instruc-
tions could cause malfunction
of the machine and result in
death, serious bodily injury and/
or property damage.

2. Know how to stop the machine and bleed pressures

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.

4. All installations must comply with local codes. Con-

tact your electrician, plumber, utility company or the
selling distributor for specific details.

To comply with the National Electrical code (NFPA
70) and provide additional protection from risk of elec-
tric shock, these pressure washers are equipped with
a UL approved ground fault circuit interrupter on 230
single phases and smaller.

WARNING: Flammable liquids
can create fumes which can ig-
nite causing property damage or
severe injury.

WARNING:  Risk of explosion  —
do not spray flammable liquids.

  5. Risk of explosion - do not spray

flammable liquids or operate in
an explosive location.

WARNING: Keep water spray
away from electrical wiring or fa-
tal electrical shock may result.

  6. To protect the operator from

electrical shock, the machine
must be electrically grounded.
It is the responsibility of the
owner to connect this machine
to a UL grounded receptacle of

proper voltage and amperage ratings.  Do not spray
water on or near electrical components.  Do not touch
machine with wet hands or while standing in water.
Always disconnect power before servicing.

7. Grip cleaning wand securely with both hands before

starting the cleaner. Failure to do this could result in
injury from a whipping wand.

WARNING: High pressure stream
of fluid that this equipment can
produce can pierce skin and its un-
derlying tissues, leading to serious
injury and possible amputation.

  8. High  pressure  developed  by

these machines will cause per-
sonal injury or equipment dam-
age. Use caution when operat-

ing. Do not direct discharge stream at people, or se-
vere injury or death will result.

9. Never make adjustments on machine while it is in

operation.

WARNING: High pressure spray
can cause paint chips or other
particles to become airborne and
fly at high speeds.

10. Eye safety devices and foot pro-

tection must be worn when us-
ing this equipment.

WARNING

READ OPERATOR’S

MANUAL

THOROUGHLY

PRIOR TO USE.

WARNING

USE PROTECTIVE

EYEWEAR WHEN

OPERATING.

WARNING

HIGH PRESSURE

STREAM CAN

PIERCE SKIN AND

TISSUES.

WARNING

KEEP  WATER SPRAY

AWAY FROM

ELECTRICAL WIRING.

WARNING

RISK OF EXPLOSION:

DO NOT USE WITH

FLAMMABLE

LIQUIDS.

CAUTION

Содержание MPE5-5000

Страница 1: ...TOR S MANUAL LANDA INC 4275 N W Pacific Rim Blvd Camas WA 98607 USA For technical assistance or the Landa Dealer nearest you call 800 LANDA 4 U 800 526 3248 or 360 833 9100 or consult our web page at...

Страница 2: ......

Страница 3: ...6025 Revised 5 02 Introduction 4 Important Safety Information 4 5 Pre Operation Check 5 Set up Procedures 5 Operating Instructions 5 General Washing Techniques 5 Shut Down Procedures 5 Component Ident...

Страница 4: ...or for specific details To comply with the National Electrical code NFPA 70 and provide additional protection from risk of elec tric shock these pressure washers are equipped with a UL approved ground...

Страница 5: ...attach appropriate plug end not included to power cord OPERATING INSTRUCTIONS 1 With power switch in OFF position plug power cord into a grounded type of receptacle of proper voltage and amperage rea...

Страница 6: ...tergent Tube Water Inlet Strainer Power Cord Pump Protector Pump Belt Guard Nozzle Quick Coupler Wand Unloader Rupture Disk Detergent Bucket not included High Pressure Hose Water Supply Hose not inclu...

Страница 7: ...quick coupler of the wand 6 Open spray gun Water detergent ratio is approxi mately 15 to 1 7 When you finish washing rinse by simply releasing the spray gun removing the soap nozzle and re placing the...

Страница 8: ...PERATOR S MANUAL LANDA MPE Rev 5 02 EXPLODED VIEW MPE5 50021B C LEFT SIDE 34 31 32 30 26 28 27 29 48 11 14 12 15 17 25 13 52 52 56 6 18 8 7 19 24 51 37 44 44 48 36 44 41 53 21 33 53 48 53 21 53 33 59...

Страница 9: ...TOR S MANUAL 9 LANDA MPE Rev 5 02 EXPLODED VIEW MPE5 50021B C RIGHT SIDE 55 45 48 22 16 9 21 55 45 38 45 54 20 58 55 57 35 48 55 48 55 69 44 44 42 46 For Detail See Electrical Box Illus 45 43 39 67 68...

Страница 10: ...ng P1 x 1 5 8 1 29 5 512024 Bushing H x 24mm 1 30 5 604037 Belt BX37 3 31 6 0109 Cord Serv SEO 10 4 Ft Coleman MPE5 50021C 19 6 0103 Cord Serv SO 4 4 Ft Coleman MPE5 50021B 19 ITEM PART NO DESCRIPTION...

Страница 11: ...86 ITEM PART NO DESCRIPTION QTY 1 3 1208 Injector Detergent No Couplers 1 2 2 9000 Clamp Screw 4 1 3 4 02080000 Tube 1 4 x 1 2 Clr Vinyl Ft 6 4 2 1904 Strainer 1 4 Hose Barb 1 5 2 20022 Nipple 3 8 Fem...

Страница 12: ...12 MPE SERIES PRESSUREWASHER OPERATOR S MANUAL LANDA MPE Rev 5 02 4 6 7 9 19 1 2 3 15 16 18 16 15 11 13 11 14 5 10 14 15 13 ELECTRICAL BOX EXPLODED VIEW MPE5 50021B C 8 17...

Страница 13: ...mer Micron 240 480 120V 050 KVA MPE5 50021B C 1 ELECTRICAL BOX EXPLODED VIEW MPE5 50021B C PARTS LIST ITEM PART NO DESCRIPTION QTY 9 6 021595 Din Rail In 4 10 95 07290066 Bracket E Box Chassis 1 11 6...

Страница 14: ...Wand 5000 PSI 1 3 4 01404500 Nozzle 1 4 MEG 004 5 1 4 01404515 Nozzle 1 4 MEG 1504 5 1 4 01404525 Nozzle 1 4 MEG 2504 5 1 4 01404540 Nozzle 1 4 MEG 4004 5 1 4 0146540S Nozzle 1 4 MEG 6540 1 3 2 1 5 6...

Страница 15: ...nloader valve seat worn Check and replace if necessary Worn piston package Check and replace if necessary PUMP NOISY Air in suction line Check water supply and connections on suction line Broken or we...

Страница 16: ...This pressure washer was produced with the best available materials and quality craftsmanship However you as the owner have certain responsibilities for the correct care of the equipment Attention to...

Страница 17: ...rvice including adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While...

Страница 18: ...el conocimiento de la m quina INTRODUCCION Grac as por comprar un Lavadora a Presi n Landa Estas instrucciones y advertencias corresponden a los modelos MPE5 50021B and MPE5 50021C Landa Inc se reser...

Страница 19: ...Motor Varilla Jaula Cople de Varilla Protecci n de la Banda Medidor de Aceite Bomba Disco de Ruptura Protector de la Bomba Descargador Cable El ctrico Tubo para Detergentes Tanque para Detergentes Man...

Страница 20: ...r pido hacia astr s instale la boquilla y as gurelo empujando el collar del conector hacia adelente 4 Con la pistola de aspersi n cerrada encienda la m quina y revise que no tenga fugas de agua 5 Opri...

Страница 21: ...n agua lilmpia para remover residuos de jab n 2 Apague la m quina 3 Cierre la llave de suministro de agua 4 Oprima el gatillo de la pistola de aspersi n para aliviar la presi n contenida en la misma 5...