8.917-208.0  •  HOT Operator Manual •  Rev. 03/12

11

 

 

PRESSURE W

ASHER

 

OPERA

T

OR’S MAN 

AL

  

89172080-15

SHUTTING DOWN AND CLEAN-UP

CAUTION: Al ways store your pressure washer in a 
lo ca tion where the temperature will not fall be low 
32°F (0°C). The pump in this machine is sus cep ti ble 
to per ma nent dam age if fro zen. FREEZE DAM AGE 
IS NOT COV ERED BY WARRANTY.

  1.  Stop the pressure washer, squeeze spray gun trig ger 

to release pressure.

  2. Detach water supply hose and high pressure 

hose.

  3.  Turn on the machine for a few seconds, until  re main -

ing water exits. Turn engine off im me di ate ly.

  4.  Drain the gas and oil from the engine.
  5. Do not allow high pressure hose to become 

kinked.

  6.  Store the machine and accessories in a room which 

does not reach freezing temperatures.

CAUTION: Fail ure to follow the above di rec tions will 
result in dam age to your pres sure washer.

When the pres sure washer is not being operated or 
is be ing stored for more than one month, follow these 
in struc tions:

  1.  Replenish engine oil to up per level.
 2. Drain gas 

o line from fuel tank, fuel line, fuel valve 

and carburetor.

  3.  Pour about one teaspoon of engine oil through the 

spark plug hole, pull the starter grip several times 

and re place the plug. Then pull the starter grip slow ly 
until you feel increased pressure which indicates the 
pis ton is on its compression stroke and leave it in 
that position. This closes both the intake and ex haust 
valves to prevent rusting of cylinder.

  4.  Cover the pressure washer and store in a clean, dry 

place that is well ventilated away from open fl ame  
or sparks. 

NOTE: 

The use of a fuel additive, such 

as STA-BIL

®

, or an equivalent, will minimize the 

for mu la tion of fuel deposits during shortage. Such 
ad di tives may be added to the gasoline in the fuel 
tank of the engine, or to the gasoline in a storage 
con tain er.

After Extended Storage

CAUTION: Prior to restarting, thaw out any 
pos si ble ice from pressure washer hos es,            
spray gun or wand.

Engine Maintenance

During the winter months, rare atmospheric condi-
tions may develop which will cause an icing con di tion 
in the car bu re tor. If this de vel ops, the engine may 
run rough, lose power and may stall. This temporary 
condition can be overcome by defl ecting some of the 
Hot air from the en gine over the carburetor area. 

NOTE:

 Refer to the en gine man u fac tur er's manual for

service and main te nance of the engine.

STORAGE

STEP 2:

 Turn pump 

switch ON or turn knob 
to pump po si tion then 
open spray gun to al low  
water to cool.

STEP 3:

 After water has 

cooled to less than 100°, 
turn switch or knob to 
OFF and turn off water.

STEP 1:

 Re move deter-

gent suc tion tube from 
container and insert into 
one (1) gallon of fresh 
water. Pull trig ger on 
spray gun and si phon 
water for one minute.

89172080-14

STEP 4:

 Squeeze 

trigger on spray gun 
to re lieve re main ing 
pressure. Move shut-off 
gun safety latch into its 
locked po si tion.

89172080-10

89172080-11

Pump 

Switch

Pump 

Knob

Содержание HOT 3-300

Страница 1: ...8 917 208 0 OPERATOR S MANUAL For technical assistance or the Landa Dealer nearest you consult our web page at www landa com HOT HOT 2 1100 HOT2 1500 HOT 4 2000 HOT 3 1100 HOT 3 300 89172080 1...

Страница 2: ...th serial number and date of purchase and keep in a safe place for future reference 8 917 208 0 HOT Operator Manual Rev 03 12 Introduction Important Safety Information 4 5 7 Component Identification 6...

Страница 3: ...ound fault circuit interrupter GFCI If rated more than 250 volts or more than single phase this product should only be connected to a power supply receptacle protected by a GFCI DANGER Improper connec...

Страница 4: ...pos sibility of a fall due to slippery surfaces 20 Do not overreach or stand on unstable support Keep good footing and balance at all times 21 Do not operate this machine when fatigued or under the i...

Страница 5: ...zzle Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 Pu...

Страница 6: ...fresh air may have to be piped to the burner and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans Electrical The machine when installed must be e...

Страница 7: ...hreads Move safety latch into locked position STEP 6 Check oil level by using supplied dip stick Use SAE 30W non detergent only STEP 7 Fill fuel tank with proper fuel 89172080 9 STEP 5 Release the cou...

Страница 8: ...en turn the vari able pressure control handle coun terclockwise to reduce pressure 89172080 13 Selection of high or low pressure is accompanied by turning the handle Note High pressure nozzle must be...

Страница 9: ...rectly into cleaning solu tion and apply to surface at low pressure for best results limit your work area to sections approxi mately 6 feet square and always apply detergent from bottom to top Allow d...

Страница 10: ...hat position This closes both the intake and exhaust valves to prevent rusting of cylinder 4 Cover the pressure washer and store in a clean dry place that is well ventilated away from open flame or sp...

Страница 11: ...s warranty Winterizing Procedure Damage due to freezing is not covered by warranty Adhere to the following cold weather procedures whenever the washer must be stored or operated outdoors under freezi...

Страница 12: ...keep fingers Side View Top View 1 16 7 16 5 32 Gap Electrode Nozzle off blade Lay blade across one contact OK if arc will span 1 2 between end of blade and other contact see illustration below Transfo...

Страница 13: ...locking screws found on the air band and close air band until black smoke appears from burner exhaust vent Note air band position Next slowly open the air band until white smoke just starts to appear...

Страница 14: ...washer Perform maintenance more often under severe conditions Date Oil Changed Month Day Year Estimated Operating Hours Since Last Oil Change Date Oil Changed Month Day Year Estimated Operating Hours...

Страница 15: ...igh limit switch Replace Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for proper size or obstruc tion DETERGENT NOT DRAWING Air leak Tighten all clamps C...

Страница 16: ...inlet water pressure Do not close trigger on spray gun for longer than 1 2 minutes OIL DRIPPINGS Oil seal worn Check and replace if necessary MACHINE SMOKES Improper fuel or water in fuel Drain tank a...

Страница 17: ...ole noid flow switch on machines with spray gun control for proper on off fuel flow control Clogged burner nozzle Replace Water not turned on Turn on water to activate burner flow switch Fuel solenoid...

Страница 18: ...ply 5 Normal maintenance service including adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OB...

Страница 19: ...Form 8 917 208 0 Revised 03 12 Printed in U S A...