LANCOM GS
-
1224 and LANCOM GS
-
1224P
쮿
Chapter 4: Operation of Web- based Management
26
EN
the power once the power required by the powered device exceeds the
Class, Short Circuit or over temperature occurs.
쮿
Parameter:
왏
Status: The status is either “Normal” or “Active”. The former means
the port is ready to link and supply the power to the powered device
at any time. The latter means the port is currently supplying power.
왏
State: “Enable” allows power supply while a device is linked to the
port; “Disable” means the port does not support PoE functions.
왏
Priority: Choices are "Normal", "Low" and "High". The former being
the default choice. In case the power required by all linked devices
exceeds the maximum available power, the switch will cut power to
the devices with the lowest priority. If ports have the same priority, the
switch will stop the power supply to the port with the highest port id.
왏
Power(W): The power consumed by the port.
왏
Current(mA): The current supplied by the port.
왏
Class: The class of the powered device linked to the port of the switch.