8. PROGRAMMING THE COOLING PARAMETERS - 230 VOLT MODEL
NOTE:
The temperature is preprogrammed per the local requirements. After the dispenser is connected
to power, the controller will automatically regulate the cabinet’s temperature and signal the refrigeration
component if necessary.
SET
fnc
Temperature Controller - 230 V
Function Button
Up Button
Set Button
Down Button
8.1 ADJUSTING THE TEMPERATURE POINT
A. Press the [
SET]
button once,
SEt
will display on the screen.
B. Press the
[SET]
button again to adjust the set point. Use the
[UP]
and
[DOWN]
buttons to
increase or decrease the value.
1.
SEt
is the set point at which the refrigeration compressor shuts off when it reaches the
entered temperature value. Default Value = 0.0˚C.
C. Press the
[SET]
button to save the entered value when done.
D. To return to the home screen, press the
[fnc]
button once.
8.2 ADJUSTING THE REFRIGERATION COMPRESSOR RELAY TRIPPING DIFFERENTIAL
A. Press the
[SET]
button until
CP
displays on the screen.
B. When
CP
displays, press
[SET]
once.
diF
will display.
1.
diF
is the refrigeration compressor relay tripping differential. The refrigeration compressor
shuts off when the temperature reaches the set point and turns back on when the
temperature is equal to the sum of the set point and the diF. Default Value = 3.3˚C.
C. Press [
SET]
to adjust the differential. Use
[UP]
and
[DOWN]
buttons to increase or decrease
the value.
D. When
diF
displays, press
[SET]
to adjust the differential. Use
[UP]
and
[DOWN]
buttons to
increase or decrease the value.
E. Press [
SET]
to save the entered value when done.
F. To return to the home screen, press the
[fnc]
button two times.
9. DISPENSER DISPOSAL
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was pur
chased. Comply with local regulations regarding disposal of the refrigerant and
insulation.