SYMPTOM
POSSIBLE CAUSE
VERIFICATION
SOLUTION
Nothing Dispenses
When Valve Activated
A. Circuit Board
malfunctioning
B. Soda & front
syrup solenoid wires
plugged into wrong
connector.
C. Water solenoid
malfunctioning.
D.Water Solenoid
Core defective
E. Circuit board
malfunctioning.
F. Circuit board
misaligned. Lever not
making contact with
circuit board sensor.
A. Programmer does not light up 24 volt
supply connected. NOTE: For Valves
made on/after Nov 2011, the amber
(orange) LED does not light up AND the
24 VOLT supply is connected.
B. ‘5 sec water’ button on programmer
dispenses small amount of syrup. Green
and red LEDs light up.
C. Programmer lights up, but does not
dispense water with ‘5 sec water’. Shut-
offs are open. Green LED lights up.
D. Rubber poppet in core is swollen or
deformed. Green LED lights up.
E. New ratio cannot be entered w/
programmer.
F. Circuit board not screwed all the way
down. Board misaligned with holes and
mounting posts.
A. Check fuser, or replace circuit
board.
B. Connect soda and front syrup to
correct connectors.
C. Replace water solenoid.
D. Replace core.
E. Replace circuit board.
F. Ensure board is aligned & screw in
board all the way down.
Valve Dispenses
Water Only
A. Syrup shut-off on
back block is closed.
B. Out of syrup.
C, Syrup solenoid
unplugged.
D. Flowmeter
unplugged.
E. Flowmeter
connector wet.
F. Circuit board
malfunctioning.
G. Flowmeter rotor
obstructed, does not
turn freely.
H. Bad Flowmeter
Sensor.
I. Bad Syrup Solenoid.
J. Syrup solenoid core
is defective.
K. Syrup side of valve
obstructed.
A. Coils click when activated by
programmer ‘syrup purge’. Green & Red
LEDs light up.
B. Syrup purge draws no syrup &
shut-off is open.
C. No clicking sound when ‘syrup purge’
activated.
D. Flow rates (0) after programmer ‘5
sec water’ pour. Green LED lights up.
E. Flow rate zero (0) after programmer
‘5 sec water’ pour. Circuit board wet. No
LEDs light up.
F. Programmer does not light up when
plugged in.
G. Flow rate zero (0) after programmer
‘5 sec water’ pour.
H. Flow rate zero (0) after programmer ‘5
sec water’ pour. Green LED lights up.
I. No clicking sound when ‘syrup purge’
activated & coils properly connected.
Green & Red LEDs light up.
J. Rubber poppet in core is swollen or
deformed.
K. Coils click when “syrup purge’
activated, shut-off is open, and syrup
supply is full. Green & Red LEDs light
up.
A. Open syrup shut-off on mounting
block.
B. Replace BIB or final.
C. Plug in syrup solenoid.
D. Plug in flowmeter connector.
E. Unplug. Dry connector. Shake
water out of plug.
F. Replace circuit board.
G. Remove obstruction or replace
flowmeter.
H. Replace flowmeter assembly.
I. Replace syrup solenoid.
J. Replace core.
K. Disassemble syrup side &
remove obstruction.
23