18
Cleaning and Sanitizing Syrup Lines - Bag in Box
Cleaning and Sanitizing Flavor Injector Lines
1. Disconnect syrup lines from BIB’s
2. Place syrup lines, with BIB connectors, in a bucket of warm
water.
3.
Activate each valve to fill the lines with warm water and
flush out syrup remaining in the lines.
4. Prepare Cleaning Solution described above.
5. Place syrup lines, with BIB connectors, into cleaning
solution.
6.
Activate each valve until lines are filled with cleaning
solution then let stand for ten (10) minutes.
7.
Flush out cleaning solution from the syrup lines using clean,
warm water.
1.
Disconnect the four (4) flavor injector lines from their bag-
in-box containers.
2.
Place flavor injector lines, with BIB connectors, in a bucket
of warm water.
3.
Activate each flavor injector line to fill the with warm water
and flush out any syrup remaining in the lines.
4. Prepare Cleaning Solution described on page 13.
5.
Place flavor injector lines, with BIB connectors, into
cleaning solution.
6.
Activate each flavor injector line until lines are filled with
cleaning solution then let stand for ten (10) minutes.
7.
Flush out cleaning solution from the flavor injector lines
using clean, warm water.
Following sanitation, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solu-
tion left in the system creates a health hazard.
!
CAUTION
Following sanitation, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solu-
tion left in the system creates a health hazard.
!
CAUTION
8. Prepare Sanitizing Solution described above.
9. Place syrup lines into sanitizing solution and activate each
valve to fill lines with sanitizer. Let sit for ten (10) minutes.
10.
Reconnect syrup lines to BIB’s and draw drinks to flush
solution from the dispenser.
11.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
8. Prepare Sanitizing Solution described on page 13.
9.
Place flavor lines into sanitizing solution and activate each
line to fill with sanitizer. Let sit for ten (10) minutes.
10. Reconnect syrup lines to bag-in-box container and draw
drinks to flush solution from the dispenser.
11.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
TROUBLESHOOTING
TROUBLE
CAUSE
REMEDY
No product when switch is
activated.
1. Malfunctioning switch assembly.
2. No power to dispenser.
3. Malfunctioning power supply.
4. Malfunctioning PCB board.
1. Replace switch assembly.
2. Check internal breaker and incoming
power.
3. Check voltage to power supply. Check
fuses.
4. Replace PCB board.
No product when switch is
activated.
1.
Keyswitch is off or keyswitch harness is
disconnected.
2. Malfunctioning switch assembly.
3. Malfunctioning VersaPour valve.
1. Turn keyswitch on and/or reconnect
keyswitch harness.
2. Replace switch assembly.
3. Replace module.
Push chute; no response.
1. Dispenser not connected to power source.
2. Wiring harness not plugged in.
3. PC board defective.
4. Malfunctioning power supply.
1. Connect dispenser to power source.
2. Plug in wiring harness.
3. Replace PC board.
4. Check voltage to power supply. Check
fuses.
Содержание Sensation 44
Страница 25: ...25 Flavor Shot Box Plumbing Diagram Unit Plumbing Diagram ...
Страница 26: ...26 Wiring Diagram 115 Volt ...
Страница 27: ...27 Wiring Diagram 220 240 Volt ...
Страница 29: ...29 ...
Страница 30: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com ...