background image

2

•  WARNING:

 Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO

2

 may 

displace oxygen in the blood. 

•  WARNING: 

Prolonged exposure to CO

2

 can be harmful. Personnel exposed to high concentrations of CO

2

 gas will experience 

tremors which are followed by a loss of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak. 

•  WARNING: 

Strict attention must be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and soft drink system.

Carbon Dioxide (CO

2

)

Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must 

be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimum of 25 PSI (0.172 MPA) line pressure, but not exceeding a maximum of 50 PSI (0.345 MPA).  

Water pressure exceeding 50 PSI (0.345 MPA) must be reduced to 50 PSI (0.345 MPA) with the provided pressure regulator. Use 

a filter in the water line to avoid equipment damage and beverage off-taste. Check the water filter periodically, as required by local 

conditions. The water supply must be protected by means of an air gap, a backflow prevention device or another approved method 

to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to flow back through the pump when it 

is shut off and contaminate the water supply. Ensure the backflow prevention device complies with ASSE and local 

standards. It is the responsibility of the installer to ensure compliance.

Water Notice

SPECIFICATIONS

DIMENSIONS

 

Width

: 30.0 inches (762 mm)

 

Depth

: 31.0 inches (787 mm)

 

Height

: 37.25 inches (946 mm)

WEIGHT

 

Shipping

: 335 lbs (152 kg)

 

Empty

: 275 lbs (125 kg)

 

Ice Capacity

: 250 lbs (113.6 kg)

 

Ice Dispensable

: 185 lbs (84 kg)

CARBON DIOXIDE (CO

2

) SUPPLY

 

Min Pressure

: 70 PSIG (0.483 MPA)

 

Max Pressure

: 80 PSIG (0.552 MPA)

FITTINGS

 

Carbonator Inlet

: 3/8 inch barb

 

Plain Water Inlet

: 3/8 inch barb

 

Brand Syrup Inlets

: 3/8 inch barb

ELECTRICAL

 

115 VAC / 60 Hz / 3.0 Amps

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 75 PSIG (0.516 MPA)

CARBONATED WATER SUPPLY

 

Min Flowing Pressure

: 25 PSI (0.172 MPA)

 

Max Static Pressure

: 50 PSI (0.345 MPA)

This unit emits a sound pressure level below 70 dB

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Numer:

Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 

electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with 

this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to 

the transformer primary. Always disconnect electrical power to the unit  to  prevent  personal injury before attempting any internal 

maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source 

to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all 

water lines are tight and units are dry before making any electrical connections!

Electrical Warning

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this 

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

Содержание Sensation 30

Страница 1: ... your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Contact Lancer Customer Service for assistance as required The dispenser is for indoor use only This unit is not a toy Children should not be supervised not to play with appliance It should not be used by children ...

Страница 2: ...35 lbs 152 kg Empty 275 lbs 125 kg Ice Capacity 250 lbs 113 6 kg Ice Dispensable 185 lbs 84 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb ELECTRICAL 115 VAC 60 Hz 3 0 Amps PLAIN WATER SUPPLY Min Flowing Pressure 75 PSIG 0 516 MPA CARBONATED WATER SUP...

Страница 3: ... accessibility of installed equipment refer to 2010 ADA Standards for Accessible Design http www ada gov NOTE The drain spider is located to the right side near the front of the bin under the ice shroud The coldplate has a cavity designed to hold the drain spider During shipment the drain spider may become dislodged from its original position Prior to installing the unit ensure the drain spider is...

Страница 4: ...your IBD s warranty but will result in the inability to control the level of ice in the ice bin which can cause damage to your dispenser ATTENTION 4 Attach Bin Stat Bracket As Shown Recommended Bin Stat Attachment Bulb Tube 5 Ensure the icemaker is installed properly to allow for removal of the Merchandiser 6 Ensure manual fill is accessible 7 Clean and maintain icemaker per manufacturer s instruc...

Страница 5: ...lve cap lever Hold open until water flows from the relief valve then close flip down the relief valve 3 Verify all Bag In Box contains syrup and check all connec tions for leaks 4 Place enough ice in the ice bin to fill approximately 1 2 of the bin before plugging in the unit 5 Connect unit power cord to grounded electical outlet The dispenser must be properly electrically grounded to avoid seriou...

Страница 6: ...cer brix cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver to adjust if needed 9 Remove syrup seperator and reinstall nozzle Replace valve cover 10 Repeat steps 1 8 for each valve 11 Re install merchandiser splash plate and top cover 12 Activate each valve until the carbonator pump comes on Release the button allow carbonator to ...

Страница 7: ... one ounce of cleaner to two gallons of water Prepare a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperature of 90 F to 110 F Extended lengths of product lines may require additional cleaning solution 1 Clean cloth towels 2 Bucket 3 Extra nozzle...

Страница 8: ...up system again A B C A Nozzle B Diffuser C Soda Lever Refer to the Automatic Agitation Warning on the first page of this manual NOTE It is recommended to perform this procedure monthly or more often if desired Use the cleaning solution described on page 7 An alternate solution of one part water to one part vinegar may be used to remove water spots and calcium deposits NOTE Always remove the ice c...

Страница 9: ...anitizing Syrup Lines Bag in Box 1 Disconnect syrup lines from BIB s 2 Place syrup lines with BIB connectors in a bucket of warm water 3 Activate each valve to fill the lines with warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve until lines are filled wit...

Страница 10: ...10 WIRING DIAGRAMS Sensation 30 115 Volt Wiring Diagram ...

Страница 11: ...SW2 SWITCH 1 MUST BE ON FOR CORRECT OPERATION 2 1 6 SW1 SWITCH 2 LOW ICE ALARM ENABLED 5 8 3 6 8 7 3 8 ON SW2 SW1 6 5 LANCER PN 06 3289 3 SW1 7 1 6 4 2 SW1 SWITCH 1 LOW ICE LED INDICATOR ENABLED 1 4 2 3 1 2 8 1 SWITCH REFILL START AFTER 7 8 OFF OFF 6 SEC DISPENSED OFF ON 9 SEC DISPENSED ON OFF 12 SEC DISPENSED ON ON 15 SEC DISPENSED SWITCH REFILL ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON ...

Страница 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com ...

Отзывы: