S8E V3 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 9 of 27
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000021
Images are for illustration purposes only as product may vary.
No 043-3 – 19 December 2019
3.12 Purge System
Progressively activate each dispensing valve or Bargun connected to the Superchiller systems
until an uninterrupted flow of soda, water (where applicable), and syrup pours from each
dispenser.
3.13 Sanitise System
Prepare sanitising solution:
Prepare sanitising solution in accordance with the manufacturer’s written recommendations
and safety guidelines.
Sanitising BIB System
•
Remove all disconnects from BIB containers.
•
Immerse all disconnects in warm water and clean using a nylon bristle brush. Rinse with
clean water.
•
Prepare sanitising solution according to manufacturer’s instructions.
•
Attach sanitising fittings to BIB disconnects, if sanitising fittings are not available cut fittings
from empty BIB bags.
•
Immerse all sanitising fittings with attached BIB disconnects in bucket of sanitising solution.
Operate all dispensing valves until the sanitising solution flows from the valve. Allow
sanitiser to remain in lines for fifteen (15) minutes.
•
Immerse all sanitising fittings with attached BIB disconnects in bucket of clean water.
Operate all dispensing valves until all sanitiser has been flushed from the system.
•
Remove sanitising fittings from BIB disconnects and re-connect disconnects to appropriate
BIB's. Operate dispensing valves until syrup flows freely.
4. Scheduled Maintenance
The following Superchiller routine maintenance should be performed at the intervals listed.
4.1 Daily
Cleaning/Sanitising
The Superchiller supplies soda water to the dispensing valves/barguns. To ensure optimum
drink quality and system performance at all times please follow cleaning and sanitising
procedures for the dispensing valves/barguns recommended by the valve/bargun
manufacturer.
Checking CO2 Supply
Ensure that the contents gauge on the CO2 Regulator reads higher than 1400kpa on the dial. If
it does not, then the CO2 cylinder is empty and must be changed using safe working practices.
Warning
To avoid personal injury and/or property damage, always secure the
CO
2
cylinder with a safety chain to prevent it from falling over; and use
appropriate protective equipment (as defined in Clause 3.3.2 of AS
5034) to handle cylinders.
Should the valve become accidentally damaged or broken off, a CO
2
cylinder can cause serious personnel injury.
4.2 Quarterly
The Superchiller should be connected to a filtered water supply. To ensure optimum drink
quality and system performance, supply water filters should be replaced every 3 months.
4.3 Half Yearly
•
Remove & Clean condenser filters on the Superchiller. When the environment is dirty and
dusty, the interval between cleaning the filters may need to be reduced. Clean condenser
with low pressure compressed air. When using compressed air always direct air from the
fan side through condenser. Remove all dust and foreign particles from refrigeration deck.