S8E V3 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 7 of 27
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000021
Images are for illustration purposes only as product may vary.
No 043-3 – 19 December 2019
Caution
Superchiller operational weight is 394kg; ensure that all supporting
structures are certified for this loading by a registered Mechanical
Engineer.
Supporting structure must be securely fixed to floors or walls.
3.5 Connecting Python
Connect Python to Chiller and Dispenser.
Caution
NOTE: The S8E Superchiller is rated to operate with a maximum of
90m of python connected at 32
°C
.
Exceeding manufacturer’s ratings may cause damage to the
Superchiller and void warranty.
Connect the Python to Chiller and Dispenser.
Refer to Python and Dispenser specifications for connection data.
Superchiller can be supplied with 4 or 5 pumps, dual carbonator, or 3 pumps single carbonator;
python should be connected to Chiller as follows:
5 Pump
4 Pump
3 Pump
SODA
RETURN A
WATER
RETURN
SODA
RETURN B
SODA
RETURN A
SODA
RETURN B
SODA
RETURN A
WATER
RETURN
SODA
SUPPLY A
WATER
SUPPLY
SODA
SUPPLY B
SODA
SUPPLY A
SODA
SUPPLY B
SODA
SUPPLY A
WATER
SUPPLY
Important:
Ensure lines from python to Superchiller connections are insulated to prevent
condensation.
Note:
For additional Soda reserve on short python lengths used in high volume accounts, it
may be necessary to extend the soda circuit by connecting the 2 spare lines in the python onto
the soda return line (i.e. double pass of soda circuit out and back from dispense point to soda
return).
3.6 Connecting to water supply
•
Using appropriate tubing and fittings connect a 10mm water supply line from Superchiller
carbonator pump inlet to a filtered, regulated water supply. (See Postmix circuit diagram
page 11-13). Installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
•
Turn on water supply, check for leaks, adjust water regulator to 172-275kpa.