manualshive.com logo in svg
background image

S8E V3 Hi-Carb Superchiller 

230V / 50Hz  

 

 

www.lancerbeverage.com 

Page 17 of 27 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No: 68000021 

Images are for illustration purposes only as product may vary. 

No 043-3 – 19 December 2019 

8.  Trouble Shooting 

8.1  Refrigeration 

TROUBLE 

CAUSE 

REMEDY 

Compressor will not 

start. 

Power Failure. 

 

 

High Pressure/temperature switch 

activated. 

LED on Ice Bank Control board 

illuminated. 

 

Ice bank control faulty contacts not 

closing. 

 

Check start mechanism components. 

 

 

Thermal overload faulty, open circuit, 

compressor seized. 

Check for blown fuse, supply cord pulled 

out or supply outlet turned off. 

 

Turn chiller “off” at supply socket then 

“on” again to reset controller. 

 

 

 

Check Ice bank control using Procedure 

on page 20. Replace if defective. 

 

If faulty, replace e.g. capacitors, start 

relays. 

 

Replace compressor, check condenser, 

check power supply, evacuate system 

and if necessary fit burnout drier to 

industry standards. 

Compressor short 

cycling on thermal 

overload (frequent 

starting and stopping 

of the compressor 

while ice bank control 

contacts remain 

closed). 

Dirty condenser. 

 

Restricted air flow over unit. 

 

Low supply voltage. 

 

Defective thermal overload. 

 

Check wiring connections. 

 

Fan motor bearings tight or seized. 

Clean condenser of all lint and dirt.  

 

Check for air restriction to condenser. 

 

Check with voltmeter. 

 

Replace compressor. 

 

Tighten if loose. 

 

Replace motor(s) 

Product too warm 

Ice bank control defective 

(permanently open circuit). 

 

 

Low refrigerant charge. 

 

 

Check agitator motor, seized or fused. 

Check Ice bank control using procedure 

on page 20.  

Replace control or probe if defective. 

 

Leak check, repair leak, charge with 

correct amount of refrigerant. 

 

Replace if not working. 

Compressor runs too 

long or doesn’t cycle. 

Location too hot. 

 

Superchiller overloaded. 

 

 

Loss of refrigerant. 

 

Condenser clogged. 

 

Fan not operating. 

Relocate or improve ventilation. 

 

Use larger model or reduce python 

length. 

 

Leak check and repair. 

 

Clean off dust, lint, grease, etc. 

 

Remove obstruction or replace motor. 

 

 

 

Содержание S8E V3 Series

Страница 1: ...www lancerbeverage com S8E V3 Hi Carb Superchiller 230V 50Hz Installation Operation Service Manual...

Страница 2: ...erbeverage com Page 2 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 Decemb...

Страница 3: ...with water 8 3 9 Electrical Connection 8 3 10 Plumbing the drain and CO2 exhaust 8 3 11 Commissioning 8 3 12 Purge System 9 3 13 Sanitise System 9 4 Scheduled Maintenance 9 4 1 Daily 9 4 2 Quarterly 9...

Страница 4: ...80 litres Construction Stainless Steel Compressor Danfoss x 2 Agitator Motor 12W 230 VAC 1 Phase Condenser Motor 20W 230 VAC 1 Phase Ice bank Control Electronic Carbonation Level Control Electronic Dr...

Страница 5: ...n injury or equipment damage 2 3 Operating Warning Superchillers are intended for indoor operation only do not operate outside unless suitably protected by a weatherproof enclosure This appliance is n...

Страница 6: ...m with the carrier 3 2 Unpacking Caution The use of gloves is recommended to protect hands from potential injury from sharp edges The Superchiller must always be handled in a vertical position Careful...

Страница 7: ...carbonator or 3 pumps single carbonator python should be connected to Chiller as follows 5 Pump 4 Pump 3 Pump SODA RETURN A WATER RETURN SODA RETURN B SODA RETURN A SODA RETURN B SODA RETURN A WATER R...

Страница 8: ...requires a separate 10 amp Postmix and a 15amp Refrigeration power supplies Check the name plate on the machine for electrical supply requirements Use only the power supply specified on the name plate...

Страница 9: ...nnects and re connect disconnects to appropriate BIB s Operate dispensing valves until syrup flows freely 4 Scheduled Maintenance The following Superchiller routine maintenance should be performed at...

Страница 10: ...res per minute replace pump Commission and purge system as per clause 6 11 and 6 12 4 5 Sanitisation of Beverage System To maintain optimum quality of dispensed product each Superchiller and its assoc...

Страница 11: ...age 11 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 December 2019 5 Postm...

Страница 12: ...of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 December 2019 5 2 Twin Carb...

Страница 13: ...13 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 December 2019 5 4 Twin Ca...

Страница 14: ...om Page 14 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 December 2019 6 E...

Страница 15: ...lancerbeverage com Page 15 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19...

Страница 16: ...z www lancerbeverage com Page 16 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043...

Страница 17: ...if necessary fit burnout drier to industry standards Compressor short cycling on thermal overload frequent starting and stopping of the compressor while ice bank control contacts remain closed Dirty...

Страница 18: ...aper cups Dirty or greasy glasses Improperly drawn drink Check carbonator control using procedure on page 21 Replace control or probe if defective Check filters Check CO2 pressure at regulator Should...

Страница 19: ...ll not run due to excessive carbonator CO2 pressure Faulty low pressure switch Defective Carbonator motor Locked up pump Motor has cut out on overload Carbonator empty faulty control board or level pr...

Страница 20: ...VAC is present on terminals N A ON 1 ON 2 terminals Work should only be performed by fully trained certified Electrical Plumbing Refrigeration Technicians 1 Remove the ice bank probe connections from...

Страница 21: ...ning 230VAC is present on terminals N A ON 1 ON 2 Work should only be performed by fully trained certified Electrical Plumbing Refrigeration Technicians 1 Remove the carbonator probe connections from...

Страница 22: ...9 BACKFLOW PREV ANDERSON 6 08000002 CARBONATOR RELIEF VALVE 7 63000163 COIL ASSY PRECHILL B 8 87000052 STRAINER FLOW INDICATOR 10 63000164 COIL ASSY SODA A 11 63000165 COIL ASSY SODA B 12 63000205 COI...

Страница 23: ...lancerbeverage com Page 23 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 D...

Страница 24: ...8 83000324 ELECTRICAL BOX ASSY 4P 5P S8E V2 83000325 ELECTRICAL BOX ASSY 3P S8E V2 9 83600811 MINI CONTACTOR C15 9 DANFOSS 10 83000278 CONTROL LEVEL I B HYDRA R2 11 83000282 COMPRESSOR START RELAY AN...

Страница 25: ...cerbeverage com Page 25 of 27 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000021 Images are for illustration purposes only as product may vary No 043 3 19 Dece...

Страница 26: ...of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty claim Any claim for labour costs must be authorized by Lancer prior...

Страница 27: ...nd pumps secured and mounted correctly in correct locations All pumps run quietly and carbonator pump switched ON OFF Check icebank probe position and tightness and correct wiring of harness Carbonato...

Отзывы: