2.3 FLOW RATE CHECK
The Dispenser’s water flow rate can be checked/calibrated using the on board computer as a timer.
To check/adjust flow rate:
A. Remove splashguard and module cover to expose flow controls and solenoids.
1. All active brands should have their shutoffs in the open position as illustrated below.
CW = Carbonated Water (sparkling)
PW = Plain Water (still)
B. Press the A and B buttons at the same time for five
seconds.
1. The Pour/Cancel button will illuminate and the
shot LED will blink 5 times.
C. Remove outer nozzle and insert syrup separator.
1. This is important to do during flow rate check so
you can determine if the separator has been
properly
installed.
NOTE:
Water will leak through to the syrup chamber
if not properly installed.
D. Place a ratio cup under the nozzle and press a
brand
button.
1. The brand’s water module will open and pour for
four
seconds.
NOTE:
Only water will pour during the flow rate check.
E. Check for 10 oz of water in the ratio cup.
1. If above or below 10 oz, adjust the water flow
control (shown on previous page) and recheck.
13