completely with water.
Carbonator empty - faulty
Carbonator probe or control.
Low water supply pressure.
Excessive CO
2
Pressure.
at least 135 kpa lower than CO
2
(install
water pressure regulator if necessary)
Check CO
2
regulator.
Check carbonator control using
procedure on page 21. Replace
control or probe if defective.
Check carbonator control
Using procedure on page 21.
Replace control or probe if defective.
A minimum of 172 kpa water supply
pressure is required
Check function & setting of CO
2
regulator.
Faucet delivers CO2
gas continuously.
Carbonator pump will not run due to
power failure or low voltage.
Pump water supply restricted.
Carbonator pump will not run due to
excessive carbonator CO
2
pressure.
Faulty low pressure switch.
Defective Carbonator motor.
Locked up pump. Motor has cut out
on overload.
Carbonator empty – faulty control
board or level probe.
Check fuses. Check power supply.
Ensure clean mains water supply tap is
open, or replace filters.
Check Carbonator CO
2
pressure
regulator for creeping. It should be set
at 480 kpa.
Ensure adequate water supply
(minimum pressure 172 kpa flowing
pressure
). Pressure switch is set to
open below 35 kpa and reset at 172
kpa.
Check operation by disconnecting
carbonator probe from wiring harness
at in line plug – pump should operate.
Replace pump.
Check carbonator control using
procedure on page 21.
Replace control or probe if defective.