background image

1

1A

3

"GRND"

1B

9

3

"HOT IN"

"HOT IN"

"HOT OUT"

2

8

4

5

15

16

14

13

12

7

3

1C

6

10

11

17

18

1D

20

19

21

9.5

AGITATOR DECK ASSEMBLY

31

ITEM PART NO.

DESCRIPTION

1

52-0369

Agitator Motor Assy

R

1A 91-0006

Agitator Motor, 115V/60Hz

1B 04-0059

Screw, 8 - 36 x 0.375

1C 05-0377

Propeller

1D 30-5113/01

Bracket

-

02-0032

Washer, Rubber (Agitator Motor Shaft)

2

52-1882

Control, Ice Bank

3

04-0061

Screw, 8 - 18 x 0.500

4

02-0041

Seal

5

05-1952

Sleeve

6

52-1560

Harness, Jumper

7

25-0060

Transformer, 115V/60Hz

8

52-0155

Harness Assy

9

11-0051

Splice, Wire

ITEM PART NO.

DESCRIPTION

10 04-0062

Plug, Fillcap

11

05-0032

Sleeve

12 51-0288/01

Deck Plate

13 50-0080/03

Insulation

14 05-0202/02

Cover, Deck Plate

15 05-0140

Retainer, 1.000 x 0.710

16 05-0141

Retainer, 1.165 x 0.845

17 52-1897

Probe Assy

18 13-0094

Bushing

19 30-8241

Bracket, Probe

20 04-1261

Screw, 6 - 32 x 1.375

21 04-0394

Screw, 6 - 32 x 0.500

R

in margin indicates new or revised material

dinecompany.com

Содержание ESCORT III

Страница 1: ...rs Right container 128 ounces 3 79 Liters Concentrate container 35oF 1 7oC constant temperature Ice bath water capacity 320 ounces 2 5 U S gallons 9 07 kg 9 46 L Ice bank 8 0 pounds 3 63 kg DRINK CAPA...

Страница 2: ...RELOCATING OR SHIPPING UNIT 9 4 1 REMOVING AN OPERATING UNIT 9 4 2 TRANSPORTING UNIT 9 4 3 SHIPPING UNIT 9 5 PERIODIC MAINTENANCE 9 5 1 LUBRICATION 9 5 2 CLEANING WATER STRAINER 9 5 3 CLEANING INLET...

Страница 3: ...2 VACUUM BREAKER LEAKS WATER OUT OF END 19 7 23 WATER CONTINUALLY OVERFLOWS FROM ICE BANK COMPARTMENT INTO CONCENTRATE COMPARTMENT AND INTO DRIP TRAY 19 7 24 COMPRESSOR STARTS AND CONTINUES TO RUN UNT...

Страница 4: ...ry kit of loose parts listed below with quantity in parenthesis from drip tray PN 05 0017 Flare Seal Washer 2 PN 22 0017 Brush 1 PN 54 0038 Dispensing Nozzle 2 or 3 PN 81 0301 Keys for Key Switch 2 PN...

Страница 5: ...s obtained C Turn key switch OFF 1 8 LOAD MINUTE PAKS A Remove lid over concentrate compartment B Minute Paks must be completely thawed and thoroughly shaken before loading C Load each Minute Pak per...

Страница 6: ...from control housing 1 Each spout of the unit is controlled by an independent Drive Printed Circuit Board PCB plugged into the Master PCB The driver PCB has adjusting knobs which control the Brix of...

Страница 7: ...e Sold Out Feature is working you may perform the following procedure 1 Load Product into machine 2 Press Reset button 3 Dispense for 20 continuous seconds NOTE The 20 second continuous dispense is ON...

Страница 8: ...nitizing container in dispenser 8 Replace check valve in sanitizing container 9 Activate valve for two 2 minutes ensuring concentrate lines are full of solution Let solution stand for five 5 minutes w...

Страница 9: ...neously through the right and either left or middle spouts without a change in Brix When the inlet water is disconnected from the unit the vacuum breaker will open automatically allowing water to drai...

Страница 10: ...4 ELECTRONIC CONTROL SYSTEM Electrical power is fed into the transformer cabinet assembly which contains independent Class II energy limiting step down transformers Each transformer is protected by a...

Страница 11: ...each side of unit until a clean stream of water is being dispensed B Remove Minute Paks CAUTION IF UNIT IS TO BE TRANSPORTED OR STORED WHEN AMBIENT TEMPERATURE IS 32 F 0 C OR LOWER STEPS C AND D MUST...

Страница 12: ...er with water NOTE Filter should be cleaned at least every three 3 months or more frequently if required D Squeeze excess water from filter and reinstall air filter and spring retainer E Reinstall spl...

Страница 13: ...otective antistatic shipping bag and install in control panel PCB Package defective driver PCB in protective antistatic shipping bag G Partially replace control panel in control housing H Reconnect al...

Страница 14: ...y it is advisable to replace both the seal and pump body Clean only with plain water a To replace seal carefully press seal out of body CAUTION USE ONLY LANCER LUBE USE OF OTHER GREASE LUBRICANT OR CO...

Страница 15: ...t exists for any other reason in the 12VDC solenoid wiring the control PCB will shut off automatically Green LED OFF When the short is removed repaired the control PCB will automatically reset 6 8 WAT...

Страница 16: ...nk and discard Set regulator at 25 PSIG 1 76 kg cm2 while activating the dispensing paddle O Remove test gauge and replace test connection cap P Reassemble unit Q Check Brix and adjust as necessary se...

Страница 17: ...at all leads are clear of any rotating equipment K Reconnect to power source When power is supplied to the EIBC there is a five minute delay before Compressor start up The Power Indicator Lamp should...

Страница 18: ...ove concentrate containers G Loosen three screws do not remove holding top cover to frame at front of unit H Loosen three screws do not remove holding top cover to frame at rear of unit I Lift top cov...

Страница 19: ...cted to control panel panel PCB PCB B Driver PCB defective B Replace driver PCB C Sensor not adjusted properly C Adjust sensor to move it closer in relation to paddle to paddle D Sensor not connected...

Страница 20: ...ystem dispenses connected to wiring harness flush solenoid valves normally B Both driver PCBs defective B Replace driver PCBs C Both FLUSH switches bad C Replace front panel 7 7 Weak drink or A Swolle...

Страница 21: ...rings on exterior concentrate container of check valve C Air leaking into elbow C Push concentrate tube onto elbow Replace tube if necessary D Air leaking into concentrate D Replace two o rings on elb...

Страница 22: ...ws from ice amount of overflow is normal when dispenser refrigeration bank compartment as ice forms cycles OFF into concentrate B Loose or defective water coil b Turn water supply OFF and compartment...

Страница 23: ...roper or loose wiring A Correct wiring Refer to wiring switches off of start diagram winding will only run for B Low voltage B Measure voltage across common a few seconds before and run terminal on co...

Страница 24: ...Driver PCB A Replace driver PCB concentrate lights B Mother PCB B Replace front panel assembly inoperative but audible alarm is OK 7 32 Front cover lamps A Switch OFF A Open front cover and turn light...

Страница 25: ...are with the key switch in the ON position and the power cord plugged in LIGHTS STATUS PROBLEM GREEN YELLOW RED ON OFF ON Key switch ON Not trying to Transformer functioning Driver PCB dispense produ...

Страница 26: ...23 LO A 4 6 5 7 3 2 24 27 1 18 21 15 20 26 17C 17A 17B 17 14 13 9 8 12 11 10 10A 23 22 25 19 16 28 29 9 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 9 1 FINAL ASSEMBLY dinecompany com...

Страница 27: ...op Cover Assy R 16 05 0290 02 Cover R 17 82 0151 Retainer Assy R 17A 05 0186 Retainer R 17B 04 0179 Washer R 17C 04 0228 Thumb Screw R 18 04 0222 Screw R 19 52 1560 Harness Jumper R 20 82 0153 02 Agit...

Страница 28: ...9 2 PUMP REGULATOR ASSEMBLY 3H 3B 3F 3G 3D 3L 3M 2 3A 4 7A 7B 7C 7D 7E 7F 12 13 14 15 11 10 VF 17B 17I VH 17D 17E VA 17G 17G 17A 17C 6 16C 16B 16A 5 1 4 3 16 7 17 8 9 18 3E 3I 3C 3K 3J dinecompany co...

Страница 29: ...plete with Motor Items 7 8 and 9 7 82 0139 Pump Body Assy 7A 04 0166 Seal 7B 82 0179 Pump Body Sub Assy 7C 05 0132 Impeller 7D 02 0090 O Ring 7E 05 0134 End Cap 7F 04 0207 Thumb Screw 8 91 0013 Motor...

Страница 30: ...21C 21B 19 18 15 14 13 12 13 7C 7B 7A 7B 8 10 16 9 24 11 25 6G 6E 6F 6E 6E 6F 6C 6D 6B 6A 6I 6H 5B 5A 23A 23B 23C 23D 23E 23F 20 4 3 2 1 22B 22D 22 21 23 5 7 6 6G 17 26 9 3 WATER CONCENTRATE COMPONENT...

Страница 31: ...um Breaker Assy 21A 01 0789 Cap 21B 02 0005 O Ring 21C 02 0110 Umbrella Check Valve 21D 48 0059 Vacuum Breaker 22 23 0184 01 Cage Assy 22A 47 0124 Water Coil Left 22B 47 0125 Water Coil Right 22C 23 0...

Страница 32: ...LANC ER COR P SAN ANTO NIO TX 1 3 2 24 25 28 17 21 17 19 22 27A 27B 14 11 27F 27E 27D 5E 5D 17 23 5B 5C 13 4 5A 9 27C 16 15 12 6 7 8 10 17 18 20 11 1 5 27 9 4 REFRIGERATION ASSEMBLY 29 dinecompany com...

Страница 33: ...Assy 12 02 0114 Grommet 13 47 0129 Tube Process 14 47 0030 Tube Process 15 04 0537 Washer 16 03 0150 Clip 17 04 0297 Nut 18 02 0094 Grommet Horseshoe 19 06 0824 04 Nameplate 20 50 0083 Insulation 21...

Страница 34: ...04 0061 Screw 8 18 x 0 500 4 02 0041 Seal 5 05 1952 Sleeve 6 52 1560 Harness Jumper 7 25 0060 Transformer 115V 60Hz 8 52 0155 Harness Assy 9 11 0051 Splice Wire ITEM PART NO DESCRIPTION 10 04 0062 Plu...

Страница 35: ...1238 Graphics Lighted Front Cover 8 05 1164 Lens Front Cover OJ 9 52 1694 Harness Wiring Jumper 10 04 0269 Screw 8 16 x 0 375 11 52 1691 PCB Assy Lamp Driver Lg Fr 12 12 0230 Switch SPST Rocker 32 9 6...

Страница 36: ...rmer Box 2 04 0184 Plunger 3 02 0102 Grommet 4 52 0381 Transformer Cabinet Sub Assy Complete 115V 60Hz 4A 82 1696 Wrapper Transformer Box 4B 25 0011 Transformer Assy 115V 60Hz 4C 04 0297 Nut 4D 11 006...

Страница 37: ...Harness 2 54 0062 Junction Block 3 04 0070 Screw 4 52 0151 Harness Assembly 5 88 0025 Sleeve 6 52 0152 Harness Assy 7 13 0025 Strain Relief 8 52 0005 Power Cord Assy 9 52 0149 Lead Assy 9 8 WIRING CO...

Страница 38: ...NSFORMER YELLOW WHITE FLOURESCENT BULB LAMP DRIVER PCB BLACK W WHITE 2 BLACK W LETTERING 1 2 BLACK RIBBED CONDENSER FAN MOTOR GREEN S 1 1 S M R RELAY COMPRESSOR C BLACK 4 2 3 THERMAL OVERLOAD 1 WHITE...

Страница 39: ...rial Bldg 32 40 Wang Lung Street Tsuen Wan N T Hong Kong Phone 852 94302585 FAX 852 24082605 e mail patrickco lancer asia com Lancer Authorized Distributors Shanghai Freser International Co Ltd China...

Страница 40: ...2 81 83 05 81 02 FAX 52 81 83 05 81 09 e mail Carlos robles lancer com mx PEL SudAmerica Ecuador Lancer Sales Company Contact Luciano Lopez Luis De Beethoven N4756 Y Capitan Rafael Ramos Sector Las Ac...