H. Assemble in reverse order.
I.
Reinstall and secure pump support on unit with four (4) screws.
J.
Reinstall concentrate pump, spout and inlet elbow fitting.
K. Turn key switch ON.
L.
Check °Brix as required (see Section 1.10).
M. Slide control panel into control housing and tighten both captive screws finger tight.
6.9
REGULATOR ASSEMBLY
A. Unplug unit power cord from electrical outlet.
B. Remove drip tray, dispensing paddles and splash plate.
C. Close inlet water shut off valve.
D. Remove tube assembly from inlet of regulator assembly.
USE A BACKUP WRENCH TO
PREVENT DAMAGE TO STRAINER.
E. Loosen nuts on outlet fitting.
F.
Remove nut on mounting bracket.
G. Remove regulator assembly.
H. Repair or replace defective parts. Use approved thread sealant.
I.
Replace regulator assembly and connect inlet water shut off, being careful to include flare seal
washer.
J.
Tighten nuts on copper outlet tube 1/4 turn, after finger tight. Open inlet water shut off valve and
check for leaks.
K. Remove cap on test connection on bottom of repaired or new regulator and connect test gauge.
L.
Replace dispensing paddle.
M. Turn key switch ON.
N. Dispense one (1) six (6) ounce (177.4 ml) drink and discard. Set regulator at 25 PSIG
(1.76 kg/cm
2
) while activating the dispensing paddle.
O. Remove test gauge and replace test connection cap.
P.
Reassemble unit.
Q. Check °Brix and adjust as necessary (see Section 1.10).
6.10 VACUUM BREAKER
A. Close inlet water shut off valve.
B. Remove lid over agitator deck.
C. Remove vacuum breaker by loosening adaptor nut on top side of tank assembly.
D. Remove cap from end of vacuum breaker.
CAUTION
USE ONLY LANCER LUBE. USE OF OTHER GREASE, LUBRICANT OR COMPOUNDS MAY
CAUSE OFF TASTE, ODOR AND/OR DAMAGE TO UNIT AND WILL VOID WARRANTY.
E. Inspect umbrella check valve and o-rings. Replace as necessary and reassemble. Lubricate
o-rings only with Lancer lube.
F.
Open inlet water shut off valve and check for leaks.
G. Dispense several drinks while observing vacuum breaker.
NO WATER SHOULD COME OUT
OF HOLE ON END OF VACUUM BREAKER CAP.
6.11 TRANSFORMER CABINET ASSEMBLY
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Remove drip tray, dispensing paddles and splash plate.
B. Unplug both wiring harnesses from back side of transformer cabinet assembly.
C. Remove fan shroud.
D. Remove cover from transformer cabinet assembly by pulling plungers and lifting off.
E. Loosen nuts at base of transformer cabinet assembly.
F.
Replace defective transformer(s).
G. To assemble, reverse above procedure.
13
dinecompany.com