3
1.10 CONNECTING THE CO
2
SUPPLY
A. Connect high pressure CO
2
regulator assembly to CO
2
cylinder. Use a new CO
2
tank washer
if regulator does not have built-in o-ring seal.
B. Place CO
2
cylinder in service location under counter, etc., and secure it with a safety chain.
C. Using appropriate tubing and fittings, connect tubing assembly to tank mount regulator using
). Use a back-up wrench to prevent damage to regulator
assembly.
D. Route gas line through hole in counter or through opening in the rear of the dispenser into area
behind splash plate.
E. Leave 12 inches (304.8 mm) of extra tubing length below the counter for servicing and moving
the dispenser.
F. Remove the protective cap from the elbow on the back of the CO
2
manifold (located on top of
mini pumps on left side of unit) and connect the CO
2
supply line for units with internal syrup
pumps.
WARNING
DO NOT TURN ON THE CO
2
SUPPLY AT THIS TIME.
G. If dispenser does not have built in syrup pumps, remove cap from CO
2
barb on carbonator relief
valve and connect to tubing.
1.11 CONNECTING TO BAG-IN-BOX (BIB) SYRUP SUPPLY (Units with built-in Syrup Pumps)
CAUTION
THE SYRUP INLET TUBING SHIPPED WITH THE INSTALLATION KIT SHOULD BE CUT INTO
PIECES EIGHT (8) FEET (2.4 M) LONG. THESE LINES CAN BE EXTENDED UP TO A MAXIMUM
OF 12 FEET (3.7 M). THE MAXIMUM HEIGHT OF THE PUMPS ABOVE THE LOWEST BIB
PACKAGE SHOULD NOT EXCEED EIGHT (8) FEET (2.4 M). IF EITHER THE HEIGHT OF PUMPS
OR LENGTH OF INLET LINE LIMITATIONS ARE EXCEEDED, REMOTE SYRUP PUMPS OR
PRESSURIZED SYRUP CONTAINERS SHOULD BE USED.
A. Remove the protective caps from the syrup pump inlets and connect syrup inlet tube assemblies
furnished in the installation kit to the syrup pumps. Lubricate o-rings before installation using an
FDA approved lubricant or water. Be careful not to cut o-rings when installing in pump.
B. Mark syrup tube assemblies at BIB hose connector end with product ID tape.
C. Route the syrup supply tubes from the unit through hole in counter, or through opening in rear
of dispenser, to the BIB syrup supply.
D. Dip hose connectors in a cup of warm water.
E. Attach the BIB hose connectors to the appropriate syrup flavor.
1.12 CONNECTING TO REMOTE BIB SYRUP PUMPS
A. Locate the remote BIB, syrup supply and pumps in a convenient location.
B. Attach the syrup supply tubes to the dispensers syrup inlet fittings (located behind the splash
plate) using a 1/4” Oetiker clamp for each syrup flavor.
C. Route the syrup supply tubes to the remote syrup pumps.
D. Complete installation of the remote syrup pump system following the manufacturer’s
instructions.
1.13 REMOTE PRESSURIZED SYRUP SUPPLY
A. Connect high pressure CO
2
regulator assembly to CO
2
cylinder. Use a new CO
2
tank washer if
regulator does not have built-in o-ring seal.
B. Place CO
2
cylinder in service location (for example, under counter) and secure CO
2
cylinder
with a safety chain.
C. Using tubing and fittings from installation kit connect tubing assembly to tank mount regulator
). Use a back-up wrench to prevent damage to regulator
assembly.
D. Locate the five gallon (figal) syrup containers and the CO
2
cylinder and regulator set in a
convenient location.
E. Attach the syrup supply tube assembly to the dispenser’s syrup inlet fittings (located behind the