Daily Cleaning

1.  Using the cleaning solution, clean top cover and all exterior 

stainless steel surfaces.

2. 

Clean exterior of dispensing valves and ice chute.

3. 

Remove cup rest then clean the drip tray and cup rest.     

Replace cup rest and drip tray when finished.

4. 

Wipe clean all splash areas using a damp cloth soaked in 

cleaning solution.

Ice Bin Cleaning - Start-Up and Monthly

1. 

Disconnect power to the dispenser

2. 

Remove Top Cover.

3. 

Melt out any remaining ice from the bin.

4. 

Remove Agitator Pin from Agitator Shaft. Slide Agitator Shaft 

rearward out Hub and pull out of rear Bearing to remove.

5. 

Remove Ice Shroud by lifting and rotating out from beneath 

the auger.

6.  Use the Cleaning Solution, and a clean cloth or soft brush, 

to clean all removable parts, sides of the Ice Bin, Auger, and 

surface of the aluminum casting.

7.  Using the Cleaning Solution and the sponge brush provided, 

clean all interior surfaces of the ice chute and the ice chute 

feed through.

8.  Repeat Step 6 for all exterior surfaces of the dispenser.
9. 

Using hot water, thoroughly rinse away the cleaning solution.

10. 

Wearing sanitary gloves, soak and clean cloth towel in                                                                 

Sanitizing Solution and wash all surfaces of removable                   

parts, sides of the Ice Bin, Auger, and surface of the          

aluminum casting.

11. 

Using the Sanitizing Solution and the sponge brush          

provided, clean all interior surfaces of the ice chute and the 

ice chute feed through.

12.  Repeat Step 10 for all exterior surfaces of the dispenser.
13.  Wearing sanitary gloves, reassemble all removable parts. 

Ensure agitator clip is locked.

14.  Fill Unit with ice and replace Top Cover.
15. 

Reconnect Dispenser to power source.

 

Refer to the Automatic Agitation Warning on page 2.

NOTE

Cleaning Solution

Mix a mild, non-abrasive detergent (e.g. Sodium Laureth 

Sulfate, dish soap) with clean, potable water at a temperature 

of 90°F to 110°F (32°C to 43°C). The mixture ratio is one ounce 

of cleaner to two gallons of water. Prepare a minimum of five 

gallons of cleaning solution. Do not use abrasive cleaners or 

solvents because they can cause permanent damage to the unit. 

Ensure rinsing is thorough, using clean, potable water at a  

temperature of 90°F to 110°F. Extended lengths of product lines 

may require additional cleaning solution.

Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF  

guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or 

state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
The cleaning procedures provided herein pertain to the Lancer equipment identified by this manual. If other equipment 

is being cleaned, follow the guidelines established by the manufacturer for that equipment.
Cleaning should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning operations.           

Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

GENERAL INFORMATION

•  Use sanitary gloves when cleaning the unit and observe all applicable safety precautions.

•  DO NOT

 use a water jet to clean or sanitize the unit.

•  DO NOT

 disconnect water lines when cleaning and sanitizing syrup lines, to avoid contamination.

•  DO NOT

 use strong bleaches or detergents; These can discolor and corrode various materials.

•  DO NOT

 use metal scrapers, sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser.

•  DO NOT

 use hot water above 140° F (60° C). This can damage the dispenser.

•  DO NOT

 spill sanitizing solution on any circuit boards. Insure all sanitizing solution is removed from the system.

ATTENTION

CLEANING AND SANITIZING

Sanitizing Solution

 

Prepare the sanitizing solution in accordance with the 

 

manufacturer’s written recommendations and safety guidelines. 

The type and concentration of sanitizing agent recommended in 

the instructions by the manufacturer shall comply with 40 CFR 

§180.940. The solution must provide 200 parts per million (PPM) 

chlorine (e.g. Sodium Hypochlorite or bleach) and a minimum of 

five gallons of sanitizing solution should be prepared.

Содержание 4400 Series

Страница 1: ...Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons including childre...

Страница 2: ...the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each dispenser must have a separate electrical circuit Do no...

Страница 3: ...ounter or have four 4 inch legs installed NOTE The dispenser should only be installed in a location where it can be overseen by trained personnel NOTE 1 Select a level well ventilated location that is...

Страница 4: ...ther similar substances down the drain may cause the Drain Tube to become clogged ATTENTION 3 A bin thermostat is required in order to control the level of ice in the dispenser Refer to ATTENTION to t...

Страница 5: ...leaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperature of 90 F to 110 F Ext...

Страница 6: ...ly 1 Connect dispenser to power source 2 Plug in wiring harness 3 Replace PC board 4 Check voltage to power supply Check fuses Push chute ice door opens but motor does not run 1 Wiring harness not plu...

Страница 7: ...to four 4 seconds in one 1 second increments can be obtained EXAMPLE For three 3 seconds ON time switch 3 should be in the ON position and switch 4 should be in the OFF position The unit is shipped w...

Страница 8: ...ispensing Wheel Assy HEX IBD 115V 82 3413 Dispensing Wheel Assy IBD 230V Only 10 1 9 11 12 13 15 14 8 9 NOTE TO ADJUST ICE FLOW REGULATOR SEE PAGE 4 230 VOLT ONLY 7 6 3 4 2 5 1 6 05 1467 Lid Back IBD2...

Страница 9: ...Hex 9 30 9801 02 Shield Nugget Ice IBD22 Pellet Ice Dispenser Sub Assembly Conversion Kit IBD22 PN 82 3955 7 1 1 1 2 5 4 9 3 8 6 LABEL FOR HOSHIZAKI ICE MAKER TO FRONT OF DISPENSER ATTACH HERE FOR HOS...

Страница 10: ...improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrigerant and in...

Страница 11: ...ISPENSERS NOT USED ON ELECTRICAL BOX BOUNDARY LOW ICE SENSOR LOW ICE SENSOR EMITTER DETECTOR MOTOR Wiring Diagram 115 Volt 60 Hz GREEN WHITE BLACK BLACK WHITE BLACK BLUE BLACK RED RED YEL BLACK WHITE...

Страница 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: