lancer 4400 Series Скачать руководство пользователя страница 1

Ice Dispenser 22” - Model 4400

LANCER INSTALLATION GUIDE

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected  before  shipment.  At  the  time  of  shipment,  the  carrier                              

accepts responsibility for the unit. Upon receiving the unit,      

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should 

not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

105°F (4°C to 41°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

®

4500

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer 

Customer Service for assistance as required.

Revision: September 2018

Lancer PN: 28-3008

Содержание 4400 Series

Страница 1: ...Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons including childre...

Страница 2: ...the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each dispenser must have a separate electrical circuit Do no...

Страница 3: ...ounter or have four 4 inch legs installed NOTE The dispenser should only be installed in a location where it can be overseen by trained personnel NOTE 1 Select a level well ventilated location that is...

Страница 4: ...ther similar substances down the drain may cause the Drain Tube to become clogged ATTENTION 3 A bin thermostat is required in order to control the level of ice in the dispenser Refer to ATTENTION to t...

Страница 5: ...leaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperature of 90 F to 110 F Ext...

Страница 6: ...ly 1 Connect dispenser to power source 2 Plug in wiring harness 3 Replace PC board 4 Check voltage to power supply Check fuses Push chute ice door opens but motor does not run 1 Wiring harness not plu...

Страница 7: ...to four 4 seconds in one 1 second increments can be obtained EXAMPLE For three 3 seconds ON time switch 3 should be in the ON position and switch 4 should be in the OFF position The unit is shipped w...

Страница 8: ...ispensing Wheel Assy HEX IBD 115V 82 3413 Dispensing Wheel Assy IBD 230V Only 10 1 9 11 12 13 15 14 8 9 NOTE TO ADJUST ICE FLOW REGULATOR SEE PAGE 4 230 VOLT ONLY 7 6 3 4 2 5 1 6 05 1467 Lid Back IBD2...

Страница 9: ...Hex 9 30 9801 02 Shield Nugget Ice IBD22 Pellet Ice Dispenser Sub Assembly Conversion Kit IBD22 PN 82 3955 7 1 1 1 2 5 4 9 3 8 6 LABEL FOR HOSHIZAKI ICE MAKER TO FRONT OF DISPENSER ATTACH HERE FOR HOS...

Страница 10: ...improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrigerant and in...

Страница 11: ...ISPENSERS NOT USED ON ELECTRICAL BOX BOUNDARY LOW ICE SENSOR LOW ICE SENSOR EMITTER DETECTOR MOTOR Wiring Diagram 115 Volt 60 Hz GREEN WHITE BLACK BLACK WHITE BLACK BLUE BLACK RED RED YEL BLACK WHITE...

Страница 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: