background image

22

TROUBLE

CAUSE

REMEDY

Water in ice bin.

1.  Cold plate drain is obstructed.

1.  Remove obstruction from drain wire.

Noisy/cavitating carbon-
ator pump.

1.  Insufficient incoming water supply pressure.
2.  Loose pump coupling.

1.  Verify incoming supply water pressure to  

carbonator pump is 40 PSI (0.276 MPA) and 
a maximum of 80 PSI (0.552 MPA). Check 
strainer for cleanliness.

2.  Tighten set screw on pump coupling.

TROUBLE

CAUSE

REMEDY

BIB pump does not op-
erate when dispensing 
valve is opened.

1.  Out of CO

2

, CO

2

 not turned on, or low CO

2

 

pressure.

2.  Out of syrup.
3.  BIB connector not tight.
4.  Kinks in syrup or gas lines.

1.  Replace CO

2

 supply, turn on CO

2

 supply, or 

adjust CO

2

 pressure to 30 PSI - 80 PSI (0.207 

MPA - 0.552 MPA).

2.  Replace syrup supply.
3.  Fasten connector tightly.
4.  Straighten or replace lines.

BIB pump operating, but 
no flow.

1.  Leak in syrup inlet or outlet line.
2.  Defective BIB pump.

1.  Replace line.
2.  Replace BIB pump.

BIB pump continues 
to operate when bag is 
empty.

1.  Leak in suction line.
2.  Leaking O-ring on pump inlet fitting.
3.  Defective syrup BIB pump.

1.  Check BIB connector, if still leaking then 

replace line.

2.  Replace O-ring. 
3.  Replace defective pump.

BIB pump fails to restart 
after bag replacement.

1.  BIB connector not on tightly.
2.  BIB connector is stopped up.
3.  Kinks in syrup line.

1.  Tighten BIB connector.
2.  Clean out or replace BIB connector.
3.  Straighten or replace line.

BIB pump fails to stop 
when dispensing valve 
is closed.

1.  Leak in discharge line or fittings.
2.  Empty BIB.
3.  Air leak on inlet line or bag connector.

1.  Repair or replace discharge line.
2.  Replace BIB.
3.  Repair or replace.

To prevent possible harm to the environment from improper disposal, recycle the unit 
by locating an authorized recycler or contact the retailer where the product was  
purchased. Comply with local regulations regarding disposal of the insulation.

Dispenser Disposal

Remote Syrup Pump Troubleshooting

Содержание 23300 Series

Страница 1: ...sit lancerworldwide com or call Tech Support Warranty 800 729 1550 6655 Lancer Boulevard San Antonio TX 78219 custserv lancerworldwide com 2018 2020 2022 Lancer Corp Lancer PN 28 3007 Revision 00 4 06...

Страница 2: ...ing the Note signal provides you with information that may help you more effectively perform the installation procedures within this manual Disregarding information will not cause damage or injury how...

Страница 3: ...ith a light pungent odor High percentages of CO2 may displace oxygen in the blood Prolonged exposure to CO2 can be harmful Personnel exposed to high concentrations of CO2 gas will experience tremors w...

Страница 4: ...dth 15 25 inches 387 mm Depth 23 25 inches 591 mm PLAIN WATER SUPPLY Min Flowing Pressure 40 PSI 0 276 MPA Max Flowing Pressure 80 PSI 0 552 MPA CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 PSI 0 621 MPA...

Страница 5: ...COUNTER CUTOUT Width 23 25 inches 591 mm Depth 23 25 inches 591 mm PLAIN WATER SUPPLY Min Flowing Pressure 40 psi 0 276 MPa Max Flowing Pressure 80 psi 0 552 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure...

Страница 6: ...s 124 kg Ice Capacity 100 lbs 45 kg 10 valve Shipping 255 lbs 116 kg Operating with Ice 304 lbs 138 kg Ice Capacity 100 lbs 45 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 psi 0 621 MPa Max Pressure 1...

Страница 7: ...PLY Min Flowing Pressure 40 PSI 0 276 MPA Max Flowing Pressure 80 PSI 0 552 MPA CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 PSI 0 621 MPA Max Pressure 110 PSI 0 758 MPA FITTINGS Carbonated Water Inlet 3...

Страница 8: ...y A B C D E F F F F F F G G G G G G I H J J K 105 65 CO2 Line Carb Water Line Electrical Drain Line Plain Water Line Syrup Line A Water Source B Water Booster C Floor Drain D Water Regulator E Remote...

Страница 9: ...weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting TOOLS REQUIRED Oetiker Pliers Tubing Cutters Wrench Slotted Screwdriver Phi...

Страница 10: ...ting 2 The selected location should be able to support the weight of the dispenser and ice after the counter cutout is made Total weight with ice for this unit could exceed 400 pounds 181 4 kg 3 If in...

Страница 11: ...23 inches 58 42 cm below the counter including the shipping risers which Lancer recommends be left attached to the unit Should the dispenser ever require removal the shipping risers will protect the i...

Страница 12: ...may cause the drain tube to become clogged ATTENTION 13 Attach BIB connectors on syrup supply line to BIB Repeat for each syrup line pump 16 Install drain lines to both front and back drain fittings t...

Страница 13: ...Tubing B Soda Water Inlet 4 Route the soda and plain water lines through the shipping riser legs in the back of the unit 1 If using freestanding conversion kit install per kit instruc tions then inse...

Страница 14: ...ing a 6 Valve unit two of the syrup lines will be capped DO NOT remove the caps from the two syrup lines See plumbing diagram for reference ATTENTION 12 Connect each syrup line to individual syrup pum...

Страница 15: ...lator at syrup pumps 4 Turn the knob on the CO2 regulator at the source all the way to the left counterclockwise to close the regulator Repeat for CO2 regulator at the syrup pumps DO NOT TURN ON CO2 S...

Страница 16: ...gas out 9 Plug in the remote carbonator 10 When carbonator stops activate each valve until the car bonator pump comes on Release the button allow carbon ator to fill and stop Repeat this process unti...

Страница 17: ...Verify that the syrup level is even with the water level Use a screwdriver to adjust if needed 6 Remove syrup separator and reinstall nozzle Replace valve ID cover 7 Repeat steps 2 6 for each valve 11...

Страница 18: ...tizing agent recommended in the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 200 parts per million PPM chlorine e g Sodium Hypochlorite or bleach and a m...

Страница 19: ...solution from the dispenser 10 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again Following sanitation rinse with end use product until there is no aft...

Страница 20: ...e pump 6 Remove kink or replace line 7 Repair or replace CO2 regulator as required Syrup only dispensed no water but CO2 gas dispensed with syrup 1 Improper water flow to dispenser 2 Carbonator pump m...

Страница 21: ...shutoff fully 3 Remove soda flow control from valve and clean out any foreign material to ensure smooth spool movement Insufficient water flow plain water drinks 1 Insufficient incoming supply pressu...

Страница 22: ...utlet line 2 Defective BIB pump 1 Replace line 2 Replace BIB pump BIB pump continues to operate when bag is empty 1 Leak in suction line 2 Leaking O ring on pump inlet fitting 3 Defective syrup BIB pu...

Страница 23: ...2077 for 23300 Illuminated Marquee PN 85 2301 for 2200 PN 85 2302 for 2300 PN 85 2303 for 23300 Water Spigot for Ambient Temperature Water Kit PN 82 3801 for PN 82 3903 for 2300 High Performance 2200...

Страница 24: ...e Drain Assembly 5 30 11742 Lid 6 05 1512 01 Drip Tray 7 23 1214 Cup Rest 8 30 7093 Splash Plate 9 30 11907 Ice Bin Cover 10 19 0397 03 LEV without mounting block 19 0434 03 LEV Self Serve Lever witho...

Страница 25: ...0405 Hole Plug 3 4 Dia SS 11 23 0862 Wire Drain Assembly Ice Cooled 12 06 4044 Plumbing Diagram Label 2323 ICDI 8 Valve SP Item Part No Description 13 23 0797 03 Cup Rest Wide Sabre Tower 14 23 1131...

Страница 26: ...26 01 17 11 12 02 13 14 03 05 04 06 07 08 09 10 19 15 16 18 20 Series 2300 High Performance Drop In...

Страница 27: ...Right Tower Structure Assy 10V 82 0992 Accessory Kit 2323 ICDI 82 1600 Label Kit 8 LEV ICDI 3 1 1 3 08 0510 Drain Tube CP ICDI Insulated Item Part No Description 01 30 16124 02 Sliding Bin Cover 2323...

Страница 28: ...d 5 05 1092 Drip Tray 6 23 1001 01 Cup Rest 7 30 5926 01 Splash Plate 8 51 6119 01 Ice Bin Cover 9 19 0397 03 LEV without mounting block 19 0434 03 LEV Self Serve Lever without mounting block 19 0435...

Страница 29: ...29 2200 Standard Performance 5 Valve 6 Valve 3 1 2 2 1 2 2200 Standard Performance 6 Valve 3 2 1 Plumbing Diagrams...

Страница 30: ...30 2300 6 Valve Standard Performance 2300 8 Valve Standard Performance 2300 10 Valve Standard Performance...

Страница 31: ...31 2300 6 Valve High Performance Plumbing Diagram 2300 8 Valve High Performance Plumbing Diagram 2300 10 Valve High Performance Plumbing Diagram...

Страница 32: ...32 2300 Standard Performance 6 Valve 2300 Standard Performance 8 Valve 9 10 9 10 1 2 3 4 5 6 7 8 9 10 2300 Standard Performance 10 Valve Tower Plumbing Diagrams...

Страница 33: ...3 PCB 2 1 2M WHITE BLACK PRESSURE SWITCH CDA SOLENOID WHITE BLACK ICE COOLED UNIVERSAL WIRING DIAGRAM WITH BIN LID SWITCH Ice Cooled Universal Wiring Diagram without Bin Lid Switch 2F 2F 2F 2F 2F M F...

Страница 34: ...591 mm 25 635 mm 15 1 4 387 mm 17 432 mm FRONT 23 1 4 591 mm 25 25 641 mm 23 1 4 591 mm 25 5 648 mm FRONT View Looking Down 30 1 4 768 mm 32 813 mm 23 1 4 591 mm 25 635 mm 2200 Cutout 2323 Cutout 302...

Отзывы: