16
1. Turn on water source.
2. Place enough ice in the ice bin to fill approximately 1/2 of
the bin before plugging in the unit.
3. Connect unit power cord to grounded electrical outlet.
Failure to disconnect the motor power supply will
damage the carbonator motor, the pump and void the
warranty.
!
ATTENTION
The dispenser must be properly electrically grounded
to avoid serious injury or fatal electrical shock. The
power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow all
local electrical codes when making connections. Each
dispenser must have a separate electrical circuit. Do
not use extension cords. Do not connect multiple
electrical devices on the same outlet.
!
WARNING
7. Turn on CO
2
at the source then turn the knob on the CO
2
regulator at source to the right (clockwise) until regulator
reads 105 psi (0.724 MPa).
8. Activate each valve until gas-out.
9. Plug in the remote carbonator.
10. When carbonator stops, activate each valve until the car-
bonator pump comes on. Release the button, allow carbon-
ator to fill and stop. Repeat this process until a steady flow
of carbonated water is achieved.
The carbonator has a 3 minute timeout feature. If the
timeout occurs, turn the deck OFF then ON by flipping
the switch on the control box.
NOTE
To check for CO
2
leaks, close the valve on the CO
2
cylinder and observe if the pressure to the system
drops with the cylinder valve closed for five minutes.
Open the cylinder valve after check.
NOTE
4. Open the pressure relief valve, located on the remote
carbonator, by flipping up on the valve cap lever. Hold open
until water flows from the relief valve; then, close (flip down)
the relief valve.
A. Pressure Relief Valve
A
5. Activate each valve to ensure a steady flow of water is
achieved.
6. Ensure carbonator is unplugged before turning on CO
2
.
DO NOT ADJUST CO
2
REGULATOR AT SYRUP PUMPS
AT THIS TIME.
Make sure carbonated water flow rate is
set before adjusting regulator at syrup pumps.
!
ATTENTION
A. CO
2
Regulator
B. Regulator Knob
A
B
Dispenser Setup