COLD CARb ICE COOLED DISpENSER, SERIES 2308 - bLUE SKY DROp IN INSTALL GUIDE pN 28-0896 - pAGE 6

2.3 DAILY CLEANING

A. Using the cleaning solution, clean Top Cover and all exterior stainless steel surfaces.  
B. Clean exterior of dispensing valves. 
C. Remove Cup Rest, clean Drip Tray and Cup Rest, and replace Cup Rest. 
D. Wipe clean all splash areas using a damp cloth soaked in cleaning solution. 
E. Clean beverage valves as specified by the valve manufacturer.

2.4 ICE bIN CLEANING - START Up AND MONTHLY

A. Disconnect power to the dispenser
B. Remove Top Cover.
C. Melt out any remaining ice from the bin.
D. Remove Splash Plate Assembly by lifting it up and out from the dispenser face.
E. Use the Cleaning Solution described in Section 2, and a clean cloth or soft brush, to clean all removable parts, sides of Ice Bin,

and surface of aluminum casting.

F.  Repeat Step E for all exterior surfaces of the dispenser.
G. Using hot water, thoroughly rinse away the cleaning solution.
H. Wearing sanitary gloves, soak a clean cloth towel in Sanitizing Solution, described in Section 2, and wash all surfaces of remov-

able parts, sides of Ice Bin and surface of aluminum casting.

I.  Repeat Step H for all metal and plastic surfaces (not labels) of the dispenser exterior.
J. Wearing sanitary gloves, reassemble all removable parts.
K.  Fill Unit with ice and replace Top Cover.
L.  Reconnect Dispenser to power source.

2.5 CLEANING AND SANITIZING bEVERAGE COMpONENTS, bAG-IN-bOX SYSTEMS

NOTE: 

Extended lengths of product lines may require more time for flushing and rinsing lines than described below.

A.  Disconnect the syrup quick disconnect coupling from the syrup packages and connect the coupling to a bag valve removed from

an empty Bag-in-Box (BIB) package.

B. Place the syrup inlet line in a clean container filled with clean, potable, room temperature water. Activate the valve until water is

dispensed. Flush and rinse the line and fittings for a minimum of sixty seconds to remove all traces of residual product.

C. Make the sanitizing solution. Place the syrup inlet line in a container filled with sanitizing solution.
D. Activate the valve and draw sanitizing solution through the line for a minimum of sixty seconds. This will ensure the line is

flushed and filled with sanitizing solution. Allow the line to stand for at least thirty minutes.

E.  Remove the bag valve from the quick disconnect coupling and reconnect the syrup inlet line to syrup package. Ready the unit

for operation.

F.  Draw drinks to refill the lines and to flush the sanitizing solution from the dispenser.
G. Test the dispenser for proper operation. Taste the dispensed product to ensure there is not an off-taste. If off-taste is found, flush

the syrup system again.

H. Repeat cleaning, rinsing, and sanitizing procedures for each valve and circuit.

3. VALVES

A. valves may be cleaned and sanitized (see preparation in Section 2) in the same manner.

1. Remove cover and disconnect power so the valve will not be activated during the cleaning procedure. Remove nozzle and dif-

fuser. Wash these parts in cleaning solution, then immerse them in a bath of sanitizing solution for 15 minutes.

2. visually inspect around nozzle area for syrup residue. This area may be cleaned with warm water and cloth or with the 

nozzle brush supplied. Wipe off dispensing lever.

3. Wearing sanitary gloves, remove, drain and air dry the nozzle and diffuser.
4. Wearing sanitary gloves, replace diffuser, twist nozzle in place.
5. Connect power and replace cover. valve is ready for operation.

i

CAUTION

Following sanitization, rinse with end-use product until there is no aftertaste. Do not use fresh water rinse. This is a NSF requirement.

Residual sanitizing solution left in the system creates a health hazard.

i

pRECAUCIóN

Después de la esterilización, enjuague con el producto final hasta que eliminar el sabor que queda. No enjuague con agua

fresca. Ésta es una exigencia de NSF. Si queda solución de esterilización en el sistema, genera un peligro para la salud.

i

ATTENTION 

Défense de rincer l’outil à l’eau fraiche immédiatement après un traitement septique. En cas de après-goût, ne purger avec le

produit final une exigence NSF.

IN CONSIDERATION OF OUR ENVIRONMENT, 

THE COMpLETE OpERATION & MAINTENANCE MANUAL (pN 28-0897) 

IS AVAILAbLE ONLINE OR TO DOWNLOAD AT WWW.LANCERCORp.COM

FOR YOUR CONVENIENCE, SCAN THIS QR CODE WITH A 

MObILE DEVICE (App REQUIRED) FOR IMMEDIATE ACCESS

Содержание 2308 Series

Страница 1: ...t intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given instruction concerning use of the appli ance by a person responsible for their safety Unit is not designed to dispense dairy products The min max ambient operating temperature for the dispenser is 40 to 90 degrees F ADVERTENCIA El dis...

Страница 2: ...for plain water ensure that it also has a shut off valve C The carbonator pump is equipped with a strainer on the inlet side A water supply containing any appreciable quantity of silt fine sand or other debris requires a filter ahead of the pump deck Clean the filter cartridge periodically depending on the condition of the water Failure to do so may starve the pump of water causing it to burn out ...

Страница 3: ...h other eletrical devices on the same outlet The keyswitch does not disable the line voltage to the transformer primary ALWAYS disconnect power to the dispenser before attempting any internal main tenance Only qualified personnel should service internal components of electrical control housing Make sure that all water lines are tight and units are dry before making any electrical connections F ADV...

Страница 4: ...te outlets All carbonated water outlets are located on the back row of the coldplate outlets Reference diagrams for details on manufacturer s default valve assignments water option designations and switch valve operation A Remove the cup rest drip tray and then splash plate B Remove the insulation over the capped outlet corresponding to the valve that is being switched C Remove the retainer clip f...

Страница 5: ...ns must be observed Instruction warnings on the product being used must be followed Other Required Supplies 1 Clean cloth towels 2 bucket 3 extra nozzle 4 sanitary gloves and 5 Small brush PN COLD CARb ICE COOLED DISpENSER SERIES 2308 bLUE SKY DROp IN INSTALL GUIDE pN 28 0896 pAGE 5 2 1 CLEANING SOLUTION Mix a mild non abrasive detergent e g Sodium Laureth Sulfate dish soap with clean potable wate...

Страница 6: ...D Activate the valve and draw sanitizing solution through the line for a minimum of sixty seconds This will ensure the line is flushed and filled with sanitizing solution Allow the line to stand for at least thirty minutes E Remove the bag valve from the quick disconnect coupling and reconnect the syrup inlet line to syrup package Ready the unit for operation F Draw drinks to refill the lines and ...

Отзывы: