1.10 START Up - CONTINUED
D. To fill all lines with water, cycle the carbonator several times by operating the dispensing valves.
1. Ensure a good flow of plain water is established from each valve.
2. Turn on CO2 at source and ensure that the HP regulator is set at 75 PSIG.
3. Operate valves until unit gases out.
4. Plug in carbonator pump motor.
5. Turn on the pump switch located on the control box.
6. Activate carbonated water valves so that the carbonator pump cycles several times and a good flow of carbonated water is
established.
NOTE:
The pump deck has a 3 minute timeout feature. If the timeout occurs, turn the deck ‘OFF’, then ‘ON’ by
flipping the switch on the control box
7. A low pressure (LP) gas regulator controls the flow of syrup to each dispensing valve. Connect BIB connectors to BIBs. Set
the LP regulator to 65 PSIG. Activate all valves to purge air from the syrup lines.
E. The dispenser bin should now be filled with ice cubes one inch below the level of the door opening.
1.11 ADJUSTING RATIO - NOTE:
Ensure the water and syrup fluids are cold prior to checking the ratio on any valve.
A. Remove the valve cover.
B. Install a syrup separator over the diffuser and through the nozzle.
C. Position the ratio cup underneath the valve.
D. Activate the valve for a known amount of time, capturing all liquids in the ratio cup.
E. Adjust the water flow rate to the desired amount (for example, 3 – 3.75 oz/sec).
F. To increase the water flow, turn the adjuster clockwise a ¼ turn at a time. To decrease, turn
the adjuster counterclockwise a ¼ turn at a time.
G. Be sure to recheck the flow each time the rate is adjusted.
H. After setting the water flow, adjust the syrup to the desired ratio.
I. Continue to test the valve until a consistent ratio is observed at least three consecutive times.
J. Repeat these steps for each valve requiring adjustment.
1.12 CHANGING WATER OpTIONS ON A VALVE (pRIOR TO INSTALLATION)
NOTE:
Each valve has a designated carbonated and plain water outlet as specified in the diagrams. All plain water outlets are
located on the front row of the cold plate outlets. All carbonated water outlets are located on the back row of the coldplate outlets.
Reference diagrams for details on manufacturer's default valve assignments, water option designations, and switch valve operation.
A. Remove the cup rest, drip tray, and then splash plate.
B. Remove the insulation over the capped outlet
corresponding to the valve that is being switched.
C. Remove the retainer clip from the capped outlet and
pull the cap off exposing the dole fitting outlet.
D. Remove the retainer clip from the plug-in fitting
corresponding to the valve that is being switched.
E. Pull the fitting off the dole fitting outlet.
F. Push the plug-in fitting onto the dole fitting outlet that was originally capped.
G. Press firmly until fitting snaps into place.
H. Reassemble the retainer clip. If the clip cannot be assembled, apply more pressure to push the plug-in fitting further onto outlet.
I. Assemble the cap fitting onto the other dole outlet fitting.
J. Press firmly until the cap snaps into place.
K. Reassemble the retainer clip. If the clip cannot be assembled,
push the cap further onto the outlet.
L. Re-insulate lines to ensure fittings and tubing are not exposed.
M. Proceed with installation.
1.13 CHANGING WATER OpTIONS ON A VALVE (AFTER INSTALLATION)
NOTE:
Depressurization of the dispenser is required.
A. For factory settings and diagrams, refer to the Operations & Service Manual PN 28-0897, available on the Lancer website.
B. Turn off & unplug the remote pump deck.
C. Shut off the water supply to the remote pump deck and the dispenser.
COLD CARb ICE COOLED DISpENSER, SERIES 2308 - bLUE SKY DROp IN INSTALL GUIDE pN 28-0896 - pAGE 4
Manufacturer's Default Config.
Water Option Designations
Switch Valve Operation
!
WARNING
Do not operate the carbonator pump deck with the water supply turned off.
!
ADVERTENCIA
No opere la plataforma de la bomba de carbonatación con el suministro de agua está apagado.
!
AVERTISSEMENT
Ne faites pas fonctionner la plate-forme de pompe du saturateur s’il n’y a pas d'alimentation en eau.
!
WARNING
Do not disconnect or cut any tubes at this time. Depressurization is required.
!
ADVERTENCIA
No desconecte o cortar cualquier tubo en este momento. Despresurización se requiere.
!
AVERTISSEMENT
Ne pas débrancher ou de couper des tubes en ce moment. Dépressurisation est nécessaire.