Ice Cooled Drop-In

Series: 2200, 2300, 23300

Lancer

®

 is a registered trademark of Lancer Corp.

ABOUT THIS GUIDE

This guide is an integral and essential part of the product and 
should be handed over to the operator after the installation to 
keep as a reference. Please read carefully the guidelines and 
warnings contained herein as they are intended to provide the 
user with essential information for the continued safe use and 
maintenance of the product. In addition, it provides 

GUIDANCE 

ONLY

 to the user on the correct services and site location of the 

unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 
inspected before shipment. At the time of shipment, the carri-
er accepts responsibility for the unit. Upon receiving the unit, 
carefully inspect the carton for visible damage. If damage exists, 
have the carrier note the damage on the freight bill and file a 
claim with carrier. Responsibility for damage to the dispenser lies 
with the carrier.

The installation or relocation of this product must be carried out by qualified personnel with up-to-date safety 
and hygiene knowledge and practical experience, in accordance with current regulations.

FOR QUALIFIED INSTALLER ONLY.

 This basic installation sheet is an initial release. If a complete operations 

manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancerworldwide.

com) for immediate access, or for your convenience, scan this QR code with a mobile device (app required) for 

immediate access to other Technical Documents and alternative translations (if available) pertaining to this unit. 

Contact Lancer Customer Service for assistance as required.

IMPORTANT SAFETY INSTRUCTIONS

The dispenser is for indoor use only. This unit is not a toy. Children should be supervised not to play with appliance. It should not 
be used by children or infirm persons without supervision. This appliance can be used by children aged from 8 years and above 
and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 
supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and 
user maintenance shall not be performed by children without supervision. The min/max ambient operating temperature for the 
dispenser is 40°F to 105°F (4°C to 41°C) at a max altitude of 16,400 ft (5,000 m). Do not operate unit outside these conditions. 
Should freezing occur, cease operation of the unit and contact authorized service technician. Service, cleaning, and sanitizing 
should be accomplished only by trained personnel. During installation, old hose sets should not be reused to connect the unit to 
the water mains; new hose sets should always be used. Applicable safety precautions must be observed. Instruction warnings on 
the product being used must be followed.

Intended Use

Check the dispenser nameplate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords 
with this unit. Do not ‘gang’ together with other electrical devices on the same outlet. 

Do not locate multiple portable socket-out-

lets or portable power supplies at the rear of the appliance. 

The key-switch does not disable the line voltage to the transformer 

primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal maintenance. The 
resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the 
unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all water lines are 
tight and units are dry before making any electrical connections!

Electrical Warning

Содержание 2200 Series

Страница 1: ...sed not to play with appliance It should not be used by children or infirm persons without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physi...

Страница 2: ...omply with NSF standards A leaking inlet water check valve will allow carbonated water to flow back through the pump when it is shut off and contaminate the water supply Ensure the backflow prevention...

Страница 3: ...g Ice Capacity 100 lbs 45 kg 10 valve Shipping 255 lbs 116 kg Operating with Ice 304 lbs 138 kg Ice Capacity 100 lbs 45 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 psi 0 621 MPa Max Pressure 110 psi...

Страница 4: ...light or overhead lighting 2 The selected location should be able to support the weight of the dispenser and ice after the counter cutout is made Total weight with ice for this unit could exceed 400 p...

Страница 5: ...can extend up to 23 inches 58 42 cm below the counter including the shipping risers which Lancer recommends be left attached to the unit Should the dispenser ever require removal the shipping risers...

Страница 6: ...milar substances down the drain may cause the drain tube to become clogged ATTENTION 13 Attach BIB connectors on syrup supply line to BIB Repeat for each syrup line pump 16 Install drain lines to both...

Страница 7: ...Route the soda and plain water lines through the shipping riser legs in the back of the unit 1 If using freestanding conversion kit install per kit instruc tions then insert and seal unit to freestan...

Страница 8: ...e to become clogged ATTENTION If installing a 6 Valve unit two of the syrup lines will be capped DO NOT remove the caps from the two syrup lines See plumbing diagram for reference ATTENTION 12 Connect...

Страница 9: ...ator at syrup pumps 4 Turn the knob on the CO2 regulator at the source all the way to the left counterclockwise to close the regulator Repeat for CO2 regulator at the syrup pumps DO NOT TURN ON CO2 SU...

Страница 10: ...ise until regulator reads 105 psi 0 724 MPa 8 Activate each valve until gas out 9 Plug in the remote carbonator 10 When carbonator stops activate each valve until the car bonator pump comes on Release...

Страница 11: ...Verify that the syrup level is even with the water level Use a screwdriver to adjust if needed 6 Remove syrup separator and reinstall nozzle Replace valve ID cover 7 Repeat steps 2 6 for each valve 11...

Страница 12: ...tizing agent recommended in the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 200 parts per million PPM chlorine e g Sodium Hypochlorite or bleach and a m...

Страница 13: ...solution from the dispenser 10 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again Following sanitation rinse with end use product until there is no aft...

Страница 14: ...Check CO2 pressure and or replace pump 6 Remove kink or replace line 7 Repair or replace CO2 regulator as required Syrup only dispensed no water but CO2 gas dispensed with syrup 1 Improper water flow...

Страница 15: ...shutoff fully 3 Remove soda flow control from valve and clean out any foreign material to ensure smooth spool movement Insufficient water flow plain water drinks 1 Insufficient incoming supply pressu...

Страница 16: ...utlet line 2 Defective BIB pump 1 Replace line 2 Replace BIB pump BIB pump continues to operate when bag is empty 1 Leak in suction line 2 Leaking O ring on pump inlet fitting 3 Defective syrup BIB pu...

Страница 17: ...17 2200 Standard Performance 5 Valve 6 Valve 3 1 2 2 1 2 2200 Standard Performance 6 Valve 3 2 1 Plumbing Diagrams...

Страница 18: ...18 2300 6 Valve Standard Performance 2300 8 Valve Standard Performance 2300 10 Valve Standard Performance...

Страница 19: ...19 2300 6 Valve High Performance Plumbing Diagram 2300 8 Valve High Performance Plumbing Diagram 2300 10 Valve High Performance Plumbing Diagram...

Страница 20: ...20 2300 Standard Performance 6 Valve 2300 Standard Performance 8 Valve 9 10 9 10 1 2 3 4 5 6 7 8 9 10 2300 Standard Performance 10 Valve Tower Plumbing Diagrams...

Страница 21: ...3 PCB 2 1 2M WHITE BLACK PRESSURE SWITCH CDA SOLENOID WHITE BLACK ICE COOLED UNIVERSAL WIRING DIAGRAM WITH BIN LID SWITCH Ice Cooled Universal Wiring Diagram without Bin Lid Switch 2F 2F 2F 2F 2F M F...

Страница 22: ...91 mm 25 635 mm 15 1 4 387 mm 17 432 mm FRONT 23 1 4 591 mm 25 25 641 mm 23 1 4 591 mm 25 5 648 mm FRONT View Looking Down 30 1 4 768 mm 32 813 mm 23 1 4 591 mm 25 635 mm 2200 Cutout 2323 Cutout 3023...

Отзывы: