background image

20

FS30

POWER SUPPL

Y

16V

3

NOZZLE

4

NOZZLE

1

NOZZLE

2

NOZZLE

LED COMMUNICA

TION LIGHTS

NOTE:

FLASH WHEN COMMUNICA

TING

REPROGRAMMING

(DIAGNOSTIC)

PROGRAM

RESET

RUN

123

4

RESET

ABLE

24V

SECONDAR

Y

PRIMAR

Y

POWER RELA

Y

CARBONA

TO

R

PUMP

CARB CAP

AGIT

AT

O

R

11

5V

VA

LVE BOARD

(DIAGNOSTIC)

BOARD

ICE LINK

(OPTIONAL)

PROBE

MDB SLA

VE

LOW

HIGH

ICE LINK BIN OPTION

8

7

5

6

4

3

1

2

DISPLA

Y

+

-

VA

LV

E

 S

TAT

U

S

1

2

3

4

SOLD OUT

CARB PROBE

CARB PUMP

BIN AGIT

AT

E

ICE

DOOR

ICE

MAKER (OPTIONAL)

LOW 

ALARM

ICE

SWITCH

BIN

SWITCH

(OPTIONAL)

CANCEL

ENTER

LANCER

FS16

KEY

CARB PUMP

TO

P V

IE

W

ICE  LINK

MDB ADDRESS

SWITCH NUMBER

SWITCH NUMBER

1

X

OO

O

2O

XO

O

O=

OFF

X=

ON

4

32

1

SLIDE BACKW

ARD

TO

 TURN ON

SIDE VIEW

SLIDE FOR

W

ARD

TO

 TURN OFF

3O

OX

O

4O

OO

O

FRONT VIEW

O

FF

LOW ICE LIGHT

RED

WHITE

BLUE

YEL

DISPENSE SWITCH

LOW ICE SENSOR EMITTER

LOW ICE SENSOR DETECT

OR

SOLENOID

NOTE:  ICE LINK IS ONL

Y

CAP

ABLE OF SUPPORTING 4 UNITS

AGIT

AT

OR

WIRING DIAGRAM

ICE

SWITCH

DOOR

BREAKER

BALLAST

BLACK

BLACK

BLACK

BLACK

WHITE

WHITE

6.3

WIRING DIAGRAM - 115V/60HZ (Figure Schematics)

Содержание 14800 Series

Страница 1: ...WIDE 8 BRANDS 12 FLAVORS 115V 60Hz 85 14810 12 ICE BEVERAGE DISPENSER ABOVE COUNTER MULTI BRAND 30 INCH WIDE 10 BRANDS 12 FLAVORS 115V 60Hz 85 14810N 12 ICE BEVERAGE DISPENSER ABOVE COUNTER MULTI BRA...

Страница 2: ...TATION IT MAY ACTIVATE UNEXPECTEDLY DO NOT PLACE HANDS OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT WHEN UNIT IS BEING SERVICED CLEANED OR SANITIZED UNPLUG DISPENSER FROM THE POWER SOURCE NOTE La...

Страница 3: ...vd San Antonio TX 78219 Phone 800 729 1500 Local Service Name __________________________________________ Local Service Phone ________________________________________ ii TABLE OF CONTENTS SPECIFICATION...

Страница 4: ...arton and remove interior packing D Lift carton up and off of the dispenser E Remove wood shipping base from the bottom of the dispenser Support dispenser while removing shipping base to prevent damag...

Страница 5: ...a potable water supply must all be sized installed and maintained according to Federal State and Local laws The water supply must be protected by means of an air gap a backflow prevention device loca...

Страница 6: ...g at the front of the unit See Figure 3 Check for leaks G Connect syrup supply lines to the 3 8 inch barb inlet fittings at the front of the unit See Figure 4 using BIB Bag In Box pumps Check for leak...

Страница 7: ...asures syrup vacuum in the Pump Inlet Line When the Syrup Package is empty the Pump increases vacuum causing the device to shut off the gas pressure to stop the Pump The Lancer Sold Out automatically...

Страница 8: ...tion may be used as long as it is prepared in accordance with the manufacturer s written recommendations and safety guidelines and provides 50 to 100 parts per million PPM available chlorine Sanitizin...

Страница 9: ...ll the shroud up and out see Figure 8 Figure 7 Figure 8 H Using cleaning solution described in Section 2 2 and a clean cloth or soft brush clean all removable parts sides of Ice Bin Ice Chute and surf...

Страница 10: ...tank and pressurize L Activate valve and draw sanitizing solution through line for a minimum of 60 seconds This will ensure line is flushed and filled with sanitizing solution Allow line to stand for...

Страница 11: ...RATE AND ADJUST THE LANCER FS30 3 1 NORMAL OPERATION A Fill cup with desired amount of ice B Place cup under nozzle below desired brand C Select up to two 2 desired bonus flavors from those available...

Страница 12: ...Y DISPENSE DELAY V 1 B1 DLY1 FS 16 SETUP PC MODE SET PC MODE OFF ON FS 16 SETUP PC TIME ON TIME MSEC 05000 FS 16 SETUP ICE STIR OFF OFF TIME MIN 00060 ON TIME MSEC 02000 CARB SENSORS UPPER LOWER 307 5...

Страница 13: ...the relief valve Allow pressure on the regulator to drop and then lock the relief valve lever into place D Turn the pressure adjusting screw on the CO2 regulator clockwise until there is resistance Op...

Страница 14: ...t of the pump 5 Unscrew the mounting bracket 6 Part should easily slide out for replacement maintenance 3 8 PRIMING THE SYRUP PUMP AT THE CORRECT PRESSURE For the Syrup Pump to operate correctly it is...

Страница 15: ...d C PC Board defective C Replace PC Board D Solenoid bracket screwed D Unscrew solenoid bracket raise too low and not opening solenoid and re screw bracket completely 4 6 Push Chute Ice Door A Dispens...

Страница 16: ...yrup A Check pressure and adjust supply not at minimum flowing pressure B Foreign debris in water and or B Remove flow control from syrup flow control suspected valve and clean out any foreign materia...

Страница 17: ...ly seated B Reattach door assembly to dispenser 4 22 Circuit breaker tripping A Valve wire harness es A Detect short by disconnecting valve shorted to itself or Faucet harnesses from Switch Panel Plat...

Страница 18: ...carbonator C Replace carbonator pump pump D Backflow preventer not D Replace backflow preventer allowing water to flow noting the flow direction arrow from pump to coldplate E Probe malfunctioning E R...

Страница 19: ...16 NOTES Please refer to the Lancer web site www lancercorp com for information relating to Lancer Installation and Service Manuals Instruction Sheets Technical Bulletins Service Bulletins etc...

Страница 20: ...1 2 3 4 11 10 9 5 13 14 6 8 7 12 20 19 18 15 16 17 21 23 22 24 25 29 27 26 28 30 31 32 34 35 36 38 37 39 40 41 33 6 ILLUSTRATIONS AND PARTS LISTINGS 6 1 FINAL ASSEMBLY 17...

Страница 21: ...14 82 3286 01 Switch Assy MB 2L 2R 15 19 0262 01 Valve Assy LFCV 0 2 Syrup Injection Natural 16 19 0261 02 Valve Assy LFCV 4 5 Soda Water Gray Item Part No Description 18 Item Part No Description 17 1...

Страница 22: ...9 8 11 ITEM PART NO DESCRIPTION QTY X X 1 02 0577 Grommet Rubber 3 G3002 X X 2 03 0368 Retainer Pin 1 Agitator IBD X X R 3 05 2293 01 Ice Shroud IC 1 X X R 4 23 1401 Agitator Assy 1 Helical IC HEX X 5...

Страница 23: ...UMP BIN AGITATE ICE DOOR ICE MAKER OPTIONAL LOW ALARM ICE SWITCH BIN SWITCH OPTIONAL CANCEL ENTER LANCER FS16 KEY CARB PUMP TOP VIEW ICE LINK MDB ADDRESS SWITCH NUMBER SWITCH NUMBER 1 X O O O 2 O X O...

Страница 24: ...T T I N G S CO 2 IS3 3 IS4 2 IS4 1 IS3 2 IS3 1 IS2 3 IS2 2 IS2 1 IS1 3 IS1 2 IS1 1 S1 3 S1 2 S1 1 S2 2 S2 1 S1 4 S3 1 S2 4 S2 3 S3 2 S3 3 S3 4 S4 2 S4 3 S4 4 S4 1 SODA1 SODA2 WATER2 SODA3 SODA4 WATER3...

Отзывы: