14
4.25
BIB pump continues to
A. Leak in suction line.
A. Replace line.
operate when bag is
B. Leaking o-ring on pump inlet
B. Replace o-ring.
empty.
fitting.
C. Defective syrup BIB pump.
C. Replace defective pump.
4.26
BIB pump fails to
A. BIB connector not on tight.
A. Tighten BIB connector.
restart after bag
B. BIB connector is stopped up.
B. Clean out or replace BIB
replacement.
connector.
C. Kinks in syrup line.
C. Straighten or replace line.
4.27
BIB pump fails to stop
A. Leak in discharge line or
A. Repair or replace discharge line.
when dispensing valve
fittings.
is closed.
B. Empty BIB.
B. Replace BIB.
C. Air leak on inlet line or bag
C. Repair or replace.
connector.
4.28
Low or no carbonation.
A. Low or no CO
2
.
A. Check CO
2
supply. Adjust CO
2
pressure to 70 psi.
B. Low water pressure.
B. Need water a booster kit.
C. Worn or defective carbonator
C. Replace carbonator pump.
pump.
D. Backflow preventer not
D. Replace backflow preventer,
allowing water to flow.
noting the flow direction arrow
(from pump-to-coldplate).
E. Probe malfunctioning.
E. Replace Probe.
F.
PCB malfunctioning.
F.
Replace PCB.
5.
EXTRA CAPABILITIES
5.1
AUTOMATIC AGITATION AND RESETTABLE BREAKER
WARNING
THIS UNIT IS EQUIPPED WITH AUTOMATIC AGITATION. IT MAY ACTIVATE UNEXPECTEDLY.
DO NOT PLACE HANDS, OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT.
WHEN UNIT IS BEING SERVICED, CLEANED, OR SANITIZED, UNPLUG DISPENSER FROM
THE POWER SOURCE.
A. Resettable breaker switch should not be used as a substitute for unplugging the dispenser from
power source to service unit.
B. Each Series 14400 ice beverage dispenser is equipped with automatic agitation for the ice bin.
1.
The unit is shipped with timing set at two (2) seconds ON every 60 minutes for
cubed
ice.
2.
The unit is shipped with timing set at four (4) seconds ON every 150 minutes for
pellet
ice.
5.3
DIAGNOSTIC
REPROGRAMMING
Only trained technicians should attempt any kind of reprogramming to new firmware version releases.
TROUBLE
CAUSE
REMEDY