background image

Figure 5

B. MENUS AND SUBMENUS

1.

Bonus Flavors

a.

Decide if the bonus flavors will be set to add an injected flavor to the brands or dispense
carbonated water/plain water.

b.

Choose the 

V

alve number (1-2) by scrolling 

UP

and 

DOWN

arrows.

c.

Use the 

LEFT

and 

RIGHT

arrows to shift to the 

T

op, 

M

iddle, or 

B

ottom "bonus" flavors

categories.

d.

Press the 

UP

and 

DOWN

arrows under 

T

op, 

M

iddle, or 

B

ottom to select it as an 

injected flavor, carbonated 

S

oda water, or plain 

W

ater.

e.

Press 

ENTER

to finalize settings.  Panel lights should confirm finalized configurations.

8

INITIALIZATION SCREEN

(BOOT UP ONLY)

LANCER FS SERIES

VER. 0.161

MAIN MENU

SUB-CATEGORY

FS-22 (NO PWB)       C

MAJOR / MINOR

2ND SUB-CATEGORY

BRANDS PER SIDE

V:1  L:2  R:2

FS-22 (NO PWB)       C

CONFIG BONUS KEY

BONUS KEY SETUP

V:1  T:F  M:F  B:F

FS-22 (NO PWB)       C

CARB / WATER SETUP

CARB / WATER SETUP

V1  B1  SODA

SOLD OUT #1

OFF

FS-22 (NO PWB)       C

NUMBER OF VALVES

1                2 

Y                Y

FS-22 (NO PWB)       C

GLOBAL CONFIG

Scrolls through Main Menu

Press "Enter" to enter sub-category

Moves cursor to right or left

Changes value (number/letter)

Press "Enter" to save changes
Press "Cancel" to exit menu

CANCEL

ENTER

FS-22 (NO PWB)       C

RELOAD DEFAULTS?

FS-22 (NO PWB)       C

CONFIG KEY AS PC

V1    B1    PC  OFF

FS-22 (NO PWB)       C

PC SETTINGS

SET PC POUR SIZE

FS-22 (NO PWB)       C

SOLD OUT

SELECT SOLDOUT

SOLD OUT #1

FS-22 (NO PWB)       C

SOFTWARE VERSION

CONTROLLER X.XXX

V1   X.XXX

SET MAIN CONFIG

FS8 (PWB)

NO                YES

RESET DEFAULTS

CONFIG KEY AS PC

V1    B1    S  F

FS-22 (NO PWB)       C

CONFIG ICE TYPE

CUBE       PELLET

FS-22 (NO PWB)       C

VW ICE STIR TMS 

ICE STIR ON     2000

FS-22 (NO PWB)       C

SYRUP PURGE

SYRUP PURGE

OFF    SINGLE    ALL

CONFIG ICE TYPE

ICE STIR OFF     60

NOTE:

C = CUBED ICE

P = PELLET ICE

O = OVERRIDDEN

Содержание 14400 SERIES

Страница 1: ...ancer all rights reserved 6655 LANCER BLVD SAN ANTONIO TEXAS 78219 USA 210 310 7000 FAX SALES NORTH AMERICA 210 310 7245 INTERNATIONAL SALES 210 310 7242 CUSTOMER SERVICE 210 310 7242 LATIN AMERICA 21...

Страница 2: ...ITATION IT MAY ACTIVATE UNEXPECTEDLY DO NOT PLACE HANDS OR FOREIGN OBJECTS IN THE ICE STORAGE COMPARTMENT WHEN UNIT IS BEING SERVICED CLEANED OR SANITIZED UNPLUG DISPENSER FROM THE POWER SOURCE NOTE L...

Страница 3: ...e __________________________________________ Local Service Phone ________________________________________ ii TABLE OF CONTENTS SPECIFICATIONS i MANUFACTURERS INTRODUCTION ii TABLE OF CONTENTS ii 1 INS...

Страница 4: ...t on the floor B Cut band and remove C Open top of carton and remove interior packing D Lift carton up and off of the dispenser E Remove wood shipping base from the bottom of the dispenser Support dis...

Страница 5: ...cted to a potable water supply must all be sized installed and maintained according to Federal State and Local laws The water supply must be protected by means of an air gap a backflow prevention devi...

Страница 6: ...of the unit See Figure 3 Check for leaks G Connect syrup supply lines to the 3 8 inch barb inlet fittings at the front of the unit See Figure 4 using BIB Bag In Box pumps Check for leaks H Connect fl...

Страница 7: ...er equipment identified by this manual If other equipment is being cleaned follow the guidelines established for that equipment B Cleaning and sanitizing should be accomplished only by trained personn...

Страница 8: ...le body E Fill a cup with clean warm water and rinse nozzle body F Make certain that the nozzle o ring is not torn or otherwise damaged If necessary replace damaged o ring with LANCER PN 02 0231 G Wet...

Страница 9: ...solution Continue rinsing until testing with phenolpthalein shows that the rinse water is free of residual detergent WARNING TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE DO NOT ATTEMPT TO REMO...

Страница 10: ...nser NOTE Please note that a fresh water rinse cannot follow sanitization of equipment Purge only with the end use product until there is no after taste in the product This is an NSF requirement L Tes...

Страница 11: ...NO PWB C CONFIG BONUS KEY BONUS KEY SETUP V 1 T F M F B F FS 22 NO PWB C CARB WATER SETUP CARB WATER SETUP V1 B1 SODA SOLD OUT 1 OFF FS 22 NO PWB C NUMBER OF VALVES 1 2 Y Y FS 22 NO PWB C GLOBAL CONFI...

Страница 12: ...e remote carbonator pump will activate periodically to fill carbonator with the appropriate amount of water NOTE To check for CO2 leaks close the valve on the CO2 cylinder and observe if the pressure...

Страница 13: ...rom the system After all lines to the Syrup Pump and Syrup Packages are connected and CO2 or air pressure is set the system should be primed as follows A Disconnect Wire to Soda Solenoid or close Shut...

Страница 14: ...id to PC board runs but Ice Door PC Board does not open B Solenoid defective B Replace Solenoid C PC Board defective C Replace PC Board D Solenoid bracket screwed D Unscrew solenoid bracket raise too...

Страница 15: ...IB Pump D Replace pump 4 15 Erratic ratio A Incoming water and or syrup A Check pressure and adjust supply not at minimum flowing pressure B Foreign debris in water and or B Remove flow control from s...

Страница 16: ...ly seated B Reattach door assembly to dispenser 4 22 Circuit breaker tripping A Valve wire harness es A Detect short by disconnecting valve shorted to itself or Faucet harnesses from Switch Panel Plat...

Страница 17: ...w preventer not D Replace backflow preventer allowing water to flow noting the flow direction arrow from pump to coldplate E Probe malfunctioning E Replace Probe F PCB malfunctioning F Replace PCB 5 E...

Страница 18: ...15 6 ILLUSTRATIONS AND PARTS LISTINGS 6 1 FINAL ASSEMBLY 1 2 5 6 3 4 9 10 7 8 11 12 14 15 37 36 13 16 17 18 19 20 21 24 22 23 28 29 30 25 26 27 31 32 33 34 35 38...

Страница 19: ...Shaft Motor IBD 17 23 1373 Agitator Assy FS IBD HEX 18 05 1555 Bearing Agitator Rear IBD 19 10 0762 Pin Hex Design FS 16 20 03 0368 Retainer Pin Agitator IBD R 21 82 3556 Dispensing Wheel Assy Hex 22...

Страница 20: ...03 0368 Retainer Pin Agitator IBD 5 82 3651 Dispensing Wheel Assy Pellet Ice R 6 30 9801 01 Shield Nugget IC R in margin indicates change NOTICE The Pellet Ice components listed on this Instruction S...

Страница 21: ...V1 BLACK BLACK WHITE BLACK WHITE BLACK POWER SUPPLY CONTROLLER BOARD DISPLAY CARB AGI FOT COMM ICE OPTIC ICE DOOR ICE SWITCH KEY SOLD OUT JV1 JV2 JV3 JV4 CARB PROBE POWER CARBONATOR BALLAST ICE AGITAT...

Страница 22: ...1 YEL BLK RED BLK BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM PLU...

Страница 23: ...sia Flat A 24 F Houston Industrial Bldg 32 40 Wang Lung Street Tsuen Wan N T Hong Kong Phone 852 94302585 FAX 852 24082605 e mail patrickco lancer asia com Lancer Authorized Distributors Shanghai Fres...

Страница 24: ...Lancer Europe Web Site www lancereurope be Belgium European Central Office Lancer Europe S A Mechelsesteenweg 592 B 1930 Zaventem Belgium Phone 32 2 755 2390 FAX 32 2 755 2399 e mail info lancereurope...

Отзывы: