TROUBLESHOOTING
TROUBLESHOOTING
Carafe or Mug not detected (flashing brew light)
•
IRD windows are dirty (wipe with moist towel and dry).
•
Mug not close enough to IRD (move further into brewer).
Water dripping from spray head
•
Spray head plugged (replace or clean spray head).
•
Normally, some water will drip from the spray head shortly after brewing.
•
Slight valve leak (debris inside valve, disconnect water and reconnect, run 1-2 full cycles of water
in carafe to dislodge debris and check).
•
Valve leak permanent, call for technical service.
Water dripping down walls of carafe area
•
Spray head plugged (replace or clean spray head)
•
Spray head leak around threads, (remove spray head, clean and re-install for tight fit)
Coffee not staying warm
•
Preheat carafe before brewing coffee (run brew cycle without filter or coffee)
•
Check volume of water by running a full cycle of water without coffee. If carafe overfills call for technical service.
•
Check voltage to coffee maker.
Water leak from back of brewer
•
Check quick connect (push connectors together firmly and slightly twist)
•
Poly line leak at brewer, call installer to repair.
•
Valve connection leak, call for technical service.