background image

PAGE 13





Drawing No. Order No.

Description

Qty

1

V3151

Nut 1” Quick Connect

2

2

V3150

Split Ring

2

3

V3105

O-Ring 215

2

4

V3145

Bypass 1” Rotor

2

5

V3146

Bypass Cap

2

6

V3147

Bypass Handle

2

7

V3148

Bypass Rotor Seal Retainer

2

8

V3152

O-ring 135

2

9

V3155

O-ring 112

2

10

V3156

O-ring 214

2

BYPASS VALVE

(Order No. V3193)

Although no tools are necessary to assemble or disassemble the valve, the wrench (shown in various positions on the 

valve) may be purchased to aid in assembly or disassembly.

Loosens Injector And 

Bypass Caps

Loosens Drive Cap

SERVICE SPANNER WRENCH

(Order No. BP2000)

Refer to page 4 for detailed operation and service instructions.

Содержание PLATINUM LINE LES X Factor Series

Страница 1: ...ratulations on purchasing your new Lancaster Water Conditioner This unit is designed to give you many years of trouble free service When installed in accordance with the following instructions and if...

Страница 2: ...mily Size Number of people in family Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Speci...

Страница 3: ...for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WAT...

Страница 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Страница 5: ...tion on the control valve The control valve has a standard refill elbow to which a 3 8 flexible tube can be connected see page 6 One polytube insert is shipped on the brine line elbow s locking clip R...

Страница 6: ...VALVE BEFORE AERATION SYSTEM AERATION SYSTEM A HOT WATER THERMAL EXPANSION TANK IS REQUIRED ON THE COLD WATER INLET OF A WATER HEATER TO SERVICE A HOT WATER THERMAL EXPANSION TANK IS REQUIRED ON THE C...

Страница 7: ...to finish the RINSE cycle It will then advance to the FILL position The brine tank will now automatically fill with the proper volume of water for the first regeneration Allow the control to automati...

Страница 8: ...y Override using or buttons number of days between regeneration 1 to 28 or OFF Press NEXT to go to step 4 Press REGEN to return to previous step STEP 4 Next Regeneration Time hour Set the hour of day...

Страница 9: ...BUT AFTER ANY UNTREATED LINES AT LEAST 12 VERTICAL COLUMN OF WATER PIPE ON TOP OF CHECK VALVE BEFORE AERATION SYSTEM AERATION SYSTEM WELL PUMP SYSTEM SUPPLY GPM MUST EQUAL OR EXCEED AERATION SYSTEM S...

Страница 10: ...10 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 013 O Ring Refer to page 17...

Страница 11: ...Description Qty 1 V3151 Nut 1 QC 1 2 V3003 Meter Assy 1 3 V3118 01 Turbine Assy 1 4 V3105 0 ring 215 1 Order number V3003 includes V3118 01 Turbine Assy and V3105 O ring 215 REFILLFLOWCONTROLASSEMBLY...

Страница 12: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Страница 13: ...r 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various positio...

Страница 14: ...Ring 2 3 V3105 O Ring 215 2 4 V3375 Fitting 1 1 Brass Sweat 2 Order No V3007 07 Description Fitting 1 1 PVC Solvent Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V...

Страница 15: ...re not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears the...

Страница 16: ...bly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible through...

Страница 17: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Страница 18: ...iston not in home position d Press NEXT and REGEN for 3 seconds or unplug power source jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires b...

Страница 19: ...PAGE 19 NOTES...

Страница 20: ...PAGE 20 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 11 19...

Отзывы: