background image

PAGE 6

PLACING  UNIT  INTO  SERVICE:

  Make  sure  inlet  and  outlet  valves  are  to  their  closed  positions.  If  using  optional 

bypass, place in bypass position. Turn on main water supply. Open a cold water faucet. This will clear the lines of any debris 

(solder, pipe dope, etc.) that may be in the line. Let water run at tap for a couple of minutes, or until clear. Turn off faucet. 

Manually add 1½ gallons of water to the brine tank.
• 

Press and hold the 

REGEN

 button for approximately 5 seconds until the motor starts. 

• 

Wait until display reads 

BACKWASH

 and numbers start counting down.

• 

Momentarily press 

REGEN

 again. Wait until display reads 

BRINE

 and numbers start counting down.

• 

Momentarily press 

REGEN

 again. Valve is now in the second 

BACKWASH

 position.

If using optional bypass 

SLOWLY

 turn bypass valve to 

DIAGNOSTIC

 position

 (figure 2)

 or slowly open inlet valve to allow 

water to slowly enter the softener.

When water is flowing steadily to drain without the presence of air, momentarily press 

REGEN

 again. Display will read 

RINSE

.

Open the outlet valve of the softener, or if using optional bypass place to 

NORMAL OPERATION MODE

 

(figure 3)

.

Allow control to finish the

 RINSE

 cycle. It will then advance to the 

FILL

 position. The brine tank will now automatically fill with 

the proper volume of water for the first regeneration.

Allow the control to automatically advance to the 

SOFTENING

 position.

Load the brine tank with salt. Solar Salt is recommended.

SANITIZING

: Use 2 oz. of 5¼% household chlorine bleach for each cubic foot of resin. Pour bleach directly into the brine 

well of the softener. Press and hold the REGEN button for 5 – 6 seconds until the motor starts running. Allow system to 

 

complete the regeneration automatically. Check for other local and state codes which may also specify sanitation methods.

FIGURE 3

FIGURE 2

STEP 5

STEP 5

 – Next Regeneration Time (minutes): Set the minutes of day for regeneration using 

 or 

 buttons. Press 

NEXT

 to return to normal operation. Press 

REGEN

 to return to 

previous step. 

RETURN TO NORMAL MODE

FIGURE 4

Содержание X Factor Series

Страница 1: ...ner This unit is designed to give you many years of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result F...

Страница 2: ...ne prior to connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control f...

Страница 3: ...er supply inlet after pressure tank and near a source for waste water utility sink floor drain or sewer line A 115 120V 60 Hz uninterrupted outlet is required Keep softener far enough away from walls...

Страница 4: ...the overflow Do not connect the tubing to the drain line on the control valve Do not run tubing above overflow height at any point PROGRAMMING THE CONTROL VALVE Note A quick reference card is stored i...

Страница 5: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 6: ...g steadily to drain without the presence of air momentarily press REGEN again Display will read RINSE Open the outlet valve of the softener or if using optional bypass place to NORMAL OPERATION MODE f...

Страница 7: ...is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow direction of the water The plug valves ena...

Страница 8: ...reinstall the PC board position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins Push the top of the PC board towards the valve until it snaps under the...

Страница 9: ...atent 6402944 is a one piece design which allows the stack to be removed using your fingers The exterior of the stack is sealed against the body bore with self lubricating EPDM o rings while the inter...

Страница 10: ...l flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The loc...

Страница 11: ...y E White 5 1 V3010 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 013 O Ring...

Страница 12: ...lbow Locking Clip 1 2 PKP10TS8 BULK Polytube insert 5 8 Option 3 V3192 WS1 Nut Drain Elbow Option 4 V3158 01 WS1 Drain Elbow Male 1 5 V3163 O ring 019 1 6 V3159 01 WS1 DLFC Retainer ASY 1 7 V3162 007...

Страница 13: ...Description 1 2 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 3 2 V3105 O Ring 215 4 2 V3149 1 PVC Male NPT Elbow Item No Qty Part No Description 1 1 H4600 3 8 Safety Brine Valve 2 2 10151 Pin 3 1 H4...

Страница 14: ...iston not in home position d Press NEXT and REGEN for 3 seconds or unplug power source jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires b...

Страница 15: ...PAGE 15...

Страница 16: ...PAGE 16 11 19 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatergroup com E mail info lancasterwatergroup com...

Отзывы: