17
300
350
400
83,3
71,4
62,5
4-STARTING
4.5- FIELD TEST
If differences exist between the test and the actual dose distribution (due to a very uneven or light soil,
low pressurised tyres, etc.), an experimental test can be performed.
First of all, the distance (in metres) as shown in the table below should be marked on the field’s ground
using a tape measure.
Next, the seed drill in working position should cover that distance.
By means of a mark made previously on the tyre, count the number of turns performed in the covered
distance. A good place whereby which to count could be the wheel’s mud scraper.
By following these steps we can obtain the actual number of turns performed in the seed dosing test.
By performing the test, we will know the actual kilograms per hectare distributed by the machine.
4.6- COULTERS DEPTH AND PRESSURE ADJUSTMENT
The coulters depth is set with an central adjuster spindle).
Previously we have explained how to adjust the pressure for each coulter individually
Machine wide Displacement (m)