USER’ S MANUAL release 1.0 

 

This manual must be considered an integral part of the projector. 

Содержание PROLUM D3

Страница 1: ...L LU U UM M M D D D3 3 3 2 2 25 5 50 0 0W W W C C CY Y YM M M c c co o ol l lo o ou u ur r r c c ch h ha a an n ng g ge e er r r USER S MANUAL release 1 0 This manual must be considered an integral part of the projector ...

Страница 2: ...on normally flammable surfaces Minimum distance from lighted objects meters Rated maximum ambient temperature indoor with ventilation Connection must be made to a power supply system fitted with efficient earthing EN60598 1 Class I fixture Replace any cracked protective shield dichroic filter or lens Ignitor circuit lamp have very high voltage Index Dimensions and weight page 2 Technical data page...

Страница 3: ...ing MSD 250W base Gy9 5 lamp Magnetic ballast with power factor correction 1 8A max 230VAC with lamp ON Colour changing system C M Y unlimited colours combination Linear dimmer from 0 to 100 STROBE runs up to 10 flashes per second DMX controlled or 20 scenes recordable on projector The projector can work in all position ...

Страница 4: ...ded to connect the mains power When in doubt consult a qualified electrician The projector can be fed with voltage between 210Vac and 240Vac on the projector body is specified if 50 or 60 Hz Over voltage can damage the electronic parts of the projector or reduce the lamp life It is advised to check the electric system before installation When the projector is switched on the starting current is pr...

Страница 5: ...ojector is not switched on the projectors are on black out version with dimmer black out or they will project white light version without dimmer black out DMX signal cable Use only shielded and twisted cables with EIA485 RS485 standards The cable must be low capacity and an impedance between 82 and 120 ohm It is preferable not to use audio cables We advise you to read the example of the following ...

Страница 6: ...On the last projector of the signal chain it is necessary to insert a resistor from 82 to 120 ohm between positive and negative terminal and Use MALE XLR 3 or 5 pin connector to connect the projectors to the DMX controller Use MALE FEMALE 3 pin connectors to connect the projector to projector Solder on PIN 1 of the XLR connector the shield of the signal cable on PIN 2 solder the negative example b...

Страница 7: ...utter Strobe Selects blackout channel open and strobe functions With the SHUT ON COLOUR function selected the shutter closes during the colour change Function DMX Values Notes Open 248 255 Close 240 247 Blackout It has priority over the dimmer Strobe 29 232 239 Maximum rate 1 flash sec Strobe 28 224 231 Strobe 27 216 223 Strobe 26 208 215 Strobe 25 200 207 Strobe 24 192 199 Strobe 23 184 191 Strob...

Страница 8: ...55 to 255 RAINBOW from maximun speed to lower speed The type of RAINBOW effect is definite from the parameter of index RAINBOW TYPE R0 R1 R2 R3 and R4 Graphic representations of the 5 patterns of RAINBOW effect x time Y colours R0 R1 CYAN CYAN MAGENTA MAGENTA YELLOW YELLOW DIMMER DIMMER R2 R3 R4 CYAN CYAN MAGENTA MAGENTA YELLOW YELLOW DIMMER DIMMER The charts represent the temporal course of each ...

Страница 9: ... visualization of the current fault code Automatic return to the default visualization if no buttons are pressed for more than 30 seconds the system automatically returns back to the default visualization the DMX INDEX if there aren t faults or the current fault code Permanent visualization of a fault when existing when a fault happens even if the Index or the Parameter mode have been enabled the ...

Страница 10: ...the same DMX value SYNCRO STROBE 1 is guarantee the synchronism 0 0 1 7 RESET COLOUR Enables the manual reset of the colours actuators the parameter is automatically reset at the end of the procedure 0 0 1 8 RESET Enables the manual reset of the projector the parameter is automatically reset at the end of the procedure 0 0 1 10 PROGRAM EXECUTION Enables the STAND ALONE function sets the number of ...

Страница 11: ...n the time in seconds of the transition from the previous step to this new one Confirm with the ENTER button Set the value of STEP HOLD Index 13 to assign the time in seconds of the hold time of this new step Confirm with the ENTER button Assign to the PROGRAM STEP parameter Index 11 the number of the step you want memorize Push the ENTER button to store Execution of the inside program If the PROG...

Страница 12: ...ameter will be equal to 0 If it is greater than 127 the parameter will be equal to 1 NOT BOOLEAN PARAMETER COLOUR CORRECTION If the value of the DMX channel is minor than 9 the parameter will remain the same If it is inclusive between 9 to 90 the parameter will be equal to 0 If it is inclusive between 91 to 171 the parameter will be equal to 1 If it is greater than 171 the parameter will be equal ...

Страница 13: ... the lamp To bend the lamp you have to operate on the A screw or on both B and C screws Screwing A the lamp goes near to the A screw Screwing B and C the lamp goes near to the B and C On request is available complete spare sparts list with wires diagrams send e mail plese The improper use of this projector cancel the guarantee and our responsibility All the information have been written and driven...