© Lampert Werktechnik GmbH
2012
15
WARNING!
IF FUSES REQUIRE EXCHANGING, THEN THEY MUST BE REPLACED WITH FUSES OF THE SAME TYPES
AND VALUES.
THE GUARANTEE IS VOID IN THE EVENT OF EXCESSIVLY HIGH FUSING!
THE DEVICE MAY ONLY BE OPENED BY A QUALIFIED ELECTRICIAN!
8.2
CARE OF THE OPTICAL COMPONENTS
Do not attempt to disassemble optical components.
Please contact the local technical customer service
department for repairs which are not covered by this
manual.
Remove dust from the lens surface with a special brush
prior to cleaning. You can obtain suitable accessories in
any photography store.
Cleaning the oculars: Do not remove the oculars (19) from
the ocular tubes (17).
Clean the outer surfaces. In doing so, blow on them.
Subsequently dry the lens with suitable cloth or paper for
the purpose. Dry the lens with circular movements from
the centre to the outside. Do not wipe over a dried lens as
they can easily be scratched.
Cleaning and exchanging the protective glass of the eye
protection filter:
Never dismantle the eye protection filter
(shutter)!
Only clean the surface. Use a cotton cloth with glass
cleaner.
If the protective glass requires exchanging, slide it
forwards out of the bracket and insert a new protective
glass in the same manner.
9. TECHNICAL DATA
9.1
TECHNICAL DATA WELDING DEVICE
Device suitable for welding in dry rooms
Mains voltage
Mains fusing
Power consumption
Closed-circuit voltage
No-load voltage
Duty cycle X
Max. charging time
Shielding gas
Maximum gas pressure
Protection class
Insulation class
Protection type
Weight
~230 V / 50-60 Hz +/-10%
T 3.15 A
400VA
30
– 43 V
43 V
80 %
0.8 s
min. ARGON 99.8%
4 bar
I
B
IP 21S
8.8 kg
9.2
TECHNICAL DATA MICROSCOPE
Optical visual protection and illumination unit for exclusive
use with PUK fine welding devices.
>>>Use only in dry rooms.
Operating temperature
Lamp "LED unit"
Protection class
Insulation class
Protection type
Weight
+5°C to +40°C
2.5W / 800mA
III
B
IP 20
3.6 Kg