background image

www.howdens.com

Page _ 12

LAMONA 

Appliances

Electrical connections   

      

  

IMPORTANT: Ensure that the electricity supply is switched off before connecting.

Your

When fitting in recirculation mode (with carbon filters) ensure the cable is shortened or securely held in place to prevent

the loose cable from falling back into the motor.

 appliance must be connected to fixed  wiring via the use of a double pole switched fused spur outlet 

with at least 3mm contact separation, The isolation switch must be accessible after installation. (See 

technical data for fuse rating).

We strongly recommend the appliance is connected by a suitably qualified person.

The product must be installed in accordance with all local regulations.

 The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and 

disconnected at the same time.

The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations 

labelled LOAD are for connection to the appliance.

IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-

Blue.....................Neutral

Brown..................Live

Green/ Yellow.....Earth

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured 

markings identifying the terminals in your spur box, proceed as follows;

The wire which is coloured blue must be connected to the terminal which is marked with the letter 

‘N’ or coloured BLACK. The wire which is coloured brown must be connected to the terminal which 

is marked with the letter ‘L’ or coloured RED. The wire which is coloured Green and Yellow must be 
connected to the terminal which is marked with the letter ‘E’ or 

Symbol

Fig 3. 

Fig 4.

 

N

L

L

N

LOAD

SUPPLY

LOAD

SUPPLY

DP

13A  250V~

FUSE

ON

Blue.

(Neutral)

Brown.

(Live)

Содержание LAM2703

Страница 1: ...Instructions and Installation LAM2703 60cm Stainless Steel LAM2704 60cm Black LAM2705 90cm Stainless Steel LAM2706 90cm Black Angled Extractor www howdens com appliance registration...

Страница 2: ...See back page for product serial number...

Страница 3: ...you doing your part to protect the environment By placing the marking on this product we declare on our own responsibility compliance to all of European safety health and environmental requirements s...

Страница 4: ...t c a r t x E Control panel layout Care and maintenance General cleaning Grease filters Carbon filters Replacing the lamps Installation Methods of extraction Extraction via ducting Extraction via reci...

Страница 5: ...or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by service agents The manufacturer shall...

Страница 6: ...tor P 3i Intensive push twice Delay function The delay function will automatically switch off the hood 5 minutes after setting The delay function can be activated on all power functions When on press...

Страница 7: ...ing Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners or strong household cleaners as they may affect the appearance of the produc...

Страница 8: ...y Refit grease filters Reconnect the power supply NOTE Thesuctionwillbe lowerwheninstalledinrecirculationmode thisisnormalandnotaproductfault Replacing the lamps The lamps on this model are service fi...

Страница 9: ...ventilation in the room when the extractor is used at the same time as an appliance burning gas or other fuels Connect the external ducting kit to the outlet of the extractor Charcoal filters are not...

Страница 10: ...ening your box you will the extractor body a two piece telescopic decorative chimney a bag of wall and screws two brackets and an outlet reducer 1 Main Extractor Body 2 Lower Chimney 3 Upper Chimney 4...

Страница 11: ...ergy other than electricity E g gas boilers Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust air Ensure adequate room ventilation is provided when th...

Страница 12: ...ity supply see electrical connections page We recommend an isolation switch that is accessible after installation 2 The outlet reducer maybe required depending on your ducting kit supplied separately...

Страница 13: ...s are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the applian...

Страница 14: ...NFORMATION General Total power consumption 142W Fuse 3 A Voltage Frequency 220 240 V 50 Hz Cable type section 0 75mm 3 core or equivalent Cable length max 1 5m Lamps 2X 1W LED natural white 4000k TROU...

Страница 15: ...urer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alterations which are likely to affect the product The guarantee is invalid if the p...

Страница 16: ...Product serial number Place sticker here ISSUE v1 050718...