23
Instructions and Installation
This hob is pre-fitted with a mains lead.
The appliance may be connected to the mains supply only by
a registered competent person.
The mains lead must not be clamped, bent, trapped, or come
into contact with hot parts of the appliance.
If the mains lead is damaged, it must be replaced by a registered
competent person (mains cable must not be longer than 2m
for safety reasons) using the same cable type as defined in the
technical data. It should be routed away from the appliance
and not trapped between the appliance and the wall.
Terminal block connection
5 x 1.5mm²
380-415V 2N~
L2
L1
N
4
3
2
1
E
L1
Black
L2
G
re
y
Neutr
al Blue
Ear
th Y
ello
w
/Gr
e
en
Supply
cord
L
L
N
4
3
2
1
E
5 x 1.5mm²
220-240V~
Black G
re
y
Neutr
al Blue
Ear
th Y
ello
w
/Gr
e
en
Supply
cord
L
L
N
4
3
2
1
E
3 x 2.5mm²
220-240V~
Copper bridge
L
Br
o
wn
Neutr
al Blue
Ear
th Y
ello
w
/Gr
e
en
Supply
cord