Product data were exported from -
Vine Antennas UK HAM Radio Amateur Radio Accessories Antennas ATU's
Export date: Thu Jul 1 10:51:45 2021 / +0000 GMT
the tuner can damage the unit.
WARNING:
In normal operation the DU 1500 L produces very high RF voltages and currents.We
do not recommend operation of this without the top cover securely installed due to the
danger of contact with high voltage.
Always be sure that a dummy load or antenna is properly connected when power is applied.
Voltages in excess of ratings can occur if no load is connected.
SPECIFICATION
FRONT PANEL INDICATORS AND CONTROLS
Meter ........................................ Cross needle Power and SWR meter
CONTROLS
Input Tuning .............................. Continuous rotation 4,5kV capacitor 330pF
Output Tuning ........................... Continuous rotation 4,5kV capacitor 330pF
Antenna Switch Selector........... Five position ceramic switch: COAX 1, Tuned and COAX 2 Tuned and BYPASS, COAX
1 DIRECT, COAX 2 DIRECT
Power Range Switch ................ Two position: 3
00W/3kW
REAR PANEL CONNECTORS
Coax 1 ...................................... SO-239 Teflon connector
Coax 2 ...................................... SO-239 Tflon connector
Balanced Line ........................... Dual high voltage ceramic terminal
Include 4:1 balun
OTHER
Frequency Coverage ................ 1.8-30MHz ,continusoly tunable
Power Maximum ....................... 3000W max 3kW
Input impedance ....................... 50ohm
Output inoedance ..................... 25-600ohm an
d wire 2000ohm
Dimension ................................. H 330xW
330xD 120
Weight ...................................... 5.5kg
CONTROL/CONNECTORS
FRONT PANEL FUNCTIONS (Refer to page 3)
- Output (Antenna)
Continously adjustable input capacitor
- POWER/SWR METER
Dual needle meter displays FORWARD and REFLECTED Power in Watts. The SWR in measured where the two
needles intersecton the red scale.
- INPUT (Transmitter)
Continuously adjustable output capacitor.
- DIRECT-TUNED OUTPUT SELECTOR
Five-position rotary switch an output coaxial connector.
- TUNED COAX 1 selects the COAX 1connector trough the impedace matching circuit. - TUNED COAX 2 selects
the COAX 2 connector trough the impedance matchi circuit. - DIRECT BYPASS selects BYPASS COAX
connector by passing the
impedance matching circuit but provinding SWR, FORWARD and REFLECTED power meter readings.
- DIRECT COAX 1 select the COAX 1 connector bypassing the impedance matching circuit but providing SWR,
FORWARD and REF
LECTED meter readings.
[ Export product details as PDF file has been powered by
| Page 3/7 |